Radwin TERRAWIN Скачать руководство пользователя страница 1

INSTALLATION

 

GUIDE

DQ0266170/O.02

TERRAWIN

Release

 

1.0

Содержание TERRAWIN

Страница 1: ...INSTALLATION GUIDE DQ0266170 O 02 TERRAWIN Release 1 0...

Страница 2: ...k items to be installed 2 4 2 6 Prepare Tools 2 4 2 7 Install Standard Mounting Kit 2 5 2 7 1 Standard Mounting Kit 2 5 2 7 2 Pole 2 6 2 7 3 Wall 2 8 2 8 Mount Nodes 2 8 2 9 Mount the ODU S optional 2...

Страница 3: ...TerraWIN Installation Guide DQ0266170 O 02 1 2 Appendix D Revision History...

Страница 4: ...erved Each site usualy consists of 4 nodes radio units where each are installed pointing at right angles to the other 90 degrees so that all 4 cover 360 degrees1 Each of these nodes is called a Distri...

Страница 5: ...TerraWIN Installation Guide DQ0266170 O 02 1 2 Basic Deployment Introduction Figure 1 1 Basic TerraWIN deployment A more detailed look at a site Figure 1 2 Nodes at Sites...

Страница 6: ...oyment Introduction Some sites are on the sides or edges of the network segment and require only 3 nodes Figure 1 3 Three Nodes at side Sites Some sites are at the corners of the network segment and r...

Страница 7: ...TerraWINRadio Unit Node The TerraWIN radio unit is shown below Both Distribution Nodes and Client Nodes are physically the same The difference between the two is in the software Figure 1 5 TerraWIN r...

Страница 8: ...ply The TerraWIN Distribution Nodes can be supplied by either a PoE or by the ODU S Client Nodes are supplied by a PoE PoE Figure 1 7 PoE ODU S The TerraWIN ODU S is shown below Figure 1 8 TerraWIN Po...

Страница 9: ...alling and aligning distribution and client nodes Connection to the nodes are via bluetooth Controller The Controller is a cloud based management application which manages a complete sector over a sin...

Страница 10: ...izing Beam forming integrated antenna Enhanced interference mitigation capability Inter intra site sync to reduce self interference Regulations supported FCC ETSI Up to 15 Client Nodes per Distributio...

Страница 11: ...ge 2 2 3 Configure Connectivity Parameters for Nodes in POP Site page 2 2 4 Check Connectivity to Nodes in POP Site page 2 4 5 Check items to be installed page 2 4 6 Prepare Tools page 2 4 Installatio...

Страница 12: ...le play WINTouch only works on android smartphones 2 3 Configure Connectivity Parameters for Nodes in POP Site Do this in the depot before deploying on site This is only required for the Distribution...

Страница 13: ...th Open WINTouch on your smartphone and follow its instructions to discover the node you have connected Figure 2 2 Connecting to node 2 3 3 Update Connectivity Parameters of Nodes Once you have establ...

Страница 14: ...ping radio using node s new IP address 3 This is only needed for nodes in the POP Site Other nodes will be connected automatically by the Controller 2 5 Check items to be installed Nodes radio units...

Страница 15: ...tribution Node requires a mounting kit Client Nodes can use a standard mounting kit or not depending on exactly where it is placed Each Distribution Node must be installed on a pole or wall 90o from e...

Страница 16: ...nt to mount the device Once it is in place rotate the pole clamp as shown then tighten both bolts Thin Pole Dia 3 4 1 1 2 page 2 6 Medium Pole Dia 2 3 page 2 7 Thick Pole Dia 3 page 2 7 Figure 2 4 Con...

Страница 17: ...olts Thick Pole 1 Diameter larger than 3 7 5cm Use worm drive clamps not supplied threaded through the holes as shown Figure 2 12 Mounting kit on a thick pole The pole clamp is not needed Figure 2 8 C...

Страница 18: ...2 13 Mounting kit on a wall 2 8 Mount Nodes Each site typically has 4 Distribution Nodes In some cases for instance if a site is at the edge of the operational zone you may want to mount 3 or 2 nodes...

Страница 19: ...TerraWIN Installation Guide DQ0266170 O 02 2 9 Mount Nodes Installation Steps Figure 2 15 Two Distribution Nodes mounted on a pole...

Страница 20: ...TerraWIN Installation Guide DQ0266170 O 02 2 10 Mount Nodes Installation Steps Figure 2 16 Three Distribution Nodes mounted on a pole...

Страница 21: ...TerraWIN Installation Guide DQ0266170 O 02 2 11 Mount Nodes Installation Steps Figure 2 17 Four Distribution Nodes mounted on a pole...

Страница 22: ...stallation Guide DQ0266170 O 02 2 12 Mount the ODU S optional Installation Steps 2 9 Mount the ODU S optional The ODU S is shown mounted with four Distribution Nodes Figure 2 18 ODU S Mounted with 4 n...

Страница 23: ...und Nodes Installation Steps 2 10 Ground Nodes Connect a ground cable to the indicated ground connection on the node as shown in the section below Figure 2 19 Ground connection on a Node 2 11 Ground t...

Страница 24: ...the guidelines here We recommend using two lightning protection units LPUs for each node installation One near the node and one near the PoE The LPU can be mounted on a pole or on a wall Make sure th...

Страница 25: ...and 3 Connect the grounding lug to a ground source 4 Remove the cable glands and thread the CAT 5e cables through them 5 Connect the cables to the LPU s sockets and the glands around the cables as sho...

Страница 26: ...of the radio as shown Figure 2 21 Node input connection This connection provides power traffic and management connection 2 Add sealant tape to the connections see Waterproofing on page 2 18 3 Route th...

Страница 27: ...ground connection 2 14 Connect PoE optional If you are not using the ODU S connect each Distribution Node via a PoE Client Nodes need a PoE in any event 6 Perform final connections via a PoE depending...

Страница 28: ...o In port c Connect power cable 2 15 Waterproofing Protect all outdoor connections from rain dust moisture and salt by taping the cable gland connection with an appropriate sealant tape We recommend u...

Страница 29: ...ations in the same manner To mount a Client Node See Mount Nodes on page 2 8 To connect a Client Node to power See Connect Node External Connections on page 2 16 2 17 Align Client Node Connect to the...

Страница 30: ...de DQ0266170 O 02 2 20 Align Client Node Installation Steps Figure 2 26 Swivel horizontally b Repeat the above in elevation Figure 2 27 Swivel vertically c WINTouch will give an indication when the be...

Страница 31: ...TerraWIN Installation Guide DQ0266170 O 02 2 21 Align Client Node Installation Steps d Once alignment is complete tighten the bolts holding the radio on the mounting kit Tighten bolts...

Страница 32: ...where it is possible for people to stand or walk inadvertently in front of the antenna 3 2 2 Grounding All OEM_Name products should be grounded during operation In addition All radio units should be...

Страница 33: ...pter supplied by OEM_Name Use the right tools Do not mount a radio unit upside down or horizontally Doing this may void you product warranty 3 2 5 Internal ESD Protection circuits OEM_Name equipment i...

Страница 34: ...uaranteed resources See also CIR BFD Bidirectional Forwarding Detection A network protocol used to detect faults between two forwarding engines connected by a link CIR Committed Information Rate A lev...

Страница 35: ...e public network itself GRE Tunnel A virtual point to point connection between two networks using the GRE protocol to carry this out HSC Hub Sync Client When using Hub Site Synchronization one unit is...

Страница 36: ...orth SSM Synchronization Status Message Provides traceability of syn chronization signals and is used in the Synchronous Ethernet standard of communication Sync E or SyncE Synchronous Ethernet A stand...

Страница 37: ...s Before proceeding to antenna installation details the following background information should be considered B 2 Considerations for Changing Antenna Parameters Let max Available Tx Power denote the m...

Страница 38: ...tions The inequality above is always satisfied by the system in accordance with the relevant regulation The precise relationship between the items in inequality is as follows Required Tx Power per rad...

Страница 39: ...FCC IC IDs on the label and refer to Table C 1 below FCC ID Q3K TRWN600G IC 5100A TRWN600G TerraWIN must be installed so as to provide a minimum separation distance from bystanders as specified in th...

Страница 40: ...lation Guide DQ0266170 O 02 D 1 Appendix D Revision History Table D 1 Revision History TerraWIN Installation Guide DQ0266170 O 00 Cat No Date Description DQ0266170 O 02 May 2020 First revision for reg...

Страница 41: ...tions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferen...

Страница 42: ...type Les unit s ext rieures et les antennes doivent tre install es UNIQUEMENT par des les professionnels de l installation qui connaissent le b timent et la s curit locaux codes et le cas ch ant sont...

Страница 43: ...ts in the United States or where FCC rules apply only those antennas certified with the product are used The use of any antenna other than those certified with the product is expressly forbidden by FC...

Страница 44: ...configurable by software to Tx power values other than those for which the product is certified it is the responsibility of the Professional Installer to restrict the Tx power to the certified limits...

Страница 45: ...kabel TV t gal vanisk isolator finnas mellan utrustningen och kabel TV n tet Unregulated In countries where the radio is not regulated the equipment can be operated in any regulation configuration be...

Страница 46: ...otector must be provided Refer to Articles 800 and 810 of the NEC for details 2 For protection of ODU against direct lightning strikes appropriate requirements of NFPA 780 should be considered in addi...

Страница 47: ...TerraWIN Installation Guide DQ0266170 O 02 F 2 Other product names are trademarks of their respective manufacturers...

Страница 48: ...com RADWIN Mexico Quinto 20 Col El Centinela Mexico DF O4450 Mexico Tel 52 55 5689 8970 Email salesmx radwin com RADWIN Peru Av Antares 213 Lima 33 Peru Tel 511 6285105 Fax 511 990304095 Email salesp...

Страница 49: ...N Installation Guide DQ0266170 O 02 G 2 RADWIN South East Asia All Season Mansion 87 38 Wireless Road Lumpinee Bangkok 10330 Thailand Tel 66811707503 Email sales radwin com RADWIN Worldwide Offices Co...

Страница 50: ...TerraWIN Installation Guide DQ0266170 O 02 1 Last page of EndPage files...

Отзывы: