SM500MK4 Service Manual
17
4.4 User Spec Setup Procedure
To Change the setting of the User SPEC, if there is some SPEC need to alter.
KEY TO PRESS
OPERATION
In the Weighing Mode, press
then turn On the Span Switch.
-- Go to Z mode.
KEY TO PRESS
OPERATION
+
[1][4][1]
-- Go to User Specification Mode
-- To change the selection for the Spec, press the
Number of the selection
-- Press the key to Save go to next Spec
-- Press ‘
-
‘ key to go back to previous Spec
-- Press ‘
PLU
’ to save and exit
-- Press ‘
Tare
’ to exit without saving
KEY TO PRESS
OPERATION
[0]
To
[2][0]
-- Select data. (Refers to Customer Spec setting)
OR
&
-- To choose scale type.
Then
-- To set. (Save data and increase SPEC No)
KEY TO PRESS
OPERATION
-- Increase the SPEC number without saving data of
the previous SPEC number.
All manuals and user guides at all-guides.com
Содержание SM-500MK4
Страница 9: ...SM500MK4 Service Manual 6 2 1 3 Bench 462 154 All manuals and user guides at all guides com ...
Страница 58: ...55 10 APPENDIX 10 1 Block Diagram 10 1 1 Bench Type All manuals and user guides at all guides com ...
Страница 59: ...56 10 1 2 Touch Screen Pole Type All manuals and user guides at all guides com ...
Страница 60: ...57 10 1 3 Elevated Type All manuals and user guides at all guides com ...