3.4 Main Group Files
Main Group is the middle category and can be assigned to a Department. The Main Group file is used
for categorizing the PLU's. Main Group Number of 1 ~ 999 are available for programming. PLU's that
are not linked to any Main Group Number will be assigned to the Main Group Number 997
automatically. TAX is assigned to every Main Group. The assigned TAX will apply for all the PLU's
assigned to the Main Group. Up to 250 data can be programmed in Main Group file. Maximum 16
characters per file are available and each with 1 line.
3.4.1 Program Main Group File
DISPLAY
OPERATION
PT
kg
$
/kg
$
REMARK
[MODE][MODE]
[MODE]
S1
→
PLU FILE
Enter S mode.
Lamp S turns on.
[3] or [
︾
]
S3
→
MGROUP FILE Select Main Group Programming.
[*] S3.0
MG
0
NO
SET
$
/kg window indicates Main
Group code.
[1][1][1] S3.0
MG
111
NO
SET
Select Main Group No.
(Ex. [1][1][1])
[*] S3.1
MG
97
(default)
DEPT NO
Enter Main Group programming,
Set the Department number.
[1]
[*]
S3.1
S3.2
MG
MG
1
DEPT NO
NAME 0
Link Main Group 111 to
Department 1.
[B][E][E][F]
[*]
S3.2
S3.3
MG
MG
BEEF
0
NAME 4
TAX NO
Name of the Main Group 111 is
“BEEF’.
Set the Tax number.
[1] S3.3
MG
1
TAX
NO
Tax of Main Group 111 is tax
number 1.
[PLU] S3
→
MGROUP FILE
Store the Main Group file, back to S
mode. If you want to exit without
saving data, press [
◇
] key and then
follow by [C] key
Note1: For tax rate programming, refer to 3.20 Tax File in S Mode. if not necessary to link the Tax Number, press [*]
key to enter next selection. This procedure will skip if SPEC 603 is set to "NO TAX".
Note2: Number after "NAME" in Total display shows the position of the cursor.
Note3: The Main Group No.1 to No.997 are available for PLU programming.