SM 110 INITIAL SETUP
17
PT
kg
$
/kg
$
[1][2][3][4]
[*]
ENTER
ENTER
PWD X
PWD X
****
Incorrect password.
Retry.
[1][1][1][1]
[*]
X1.0
ENTER
READ
PWD X
SALES
****
DAILY
Correct password.
Enters X mode.
[MODE] S1
→
PLU FILE
Enters S mode.
Lamp S turns on.
[MODE]
ENTER
PWD
Z
Need Z mode password.
Lamp Z turns on.
[3][3]
[*]
Z1.0
ENTER
RESET
PWD Z
SALES
**
DAILY
Correct password.
Enters Z mode.
[MODE]
ENTER
PWD P
Need PWD mode password.
[1][2][3][4]
[*]
ENTER
PWD X
PWD P
1111
****
SET
Correct password.
Enters PWD mode.
[MODE] 0.000
0.000
0.00
0.00
Back to Weight mode.
Lamp R turns on.
2.7 Clear Files
T
his function is used to clear files in Memory.
DISPLAY
OPERATION
PT
kg
$
/kg
$
REMARK
Z1.0
RESET
SALES
DAILY
Z mode.
Lamp Z turns on.
[[2][3][0]
CLEAR
PLU FILE
PLU
file.
[
︾
]
CLEAR
VENDER
DATA
Vender transaction data.
[
︾
]
CLEAR
REPORT FILES
Report files.
[
︾
]
CLEAR
MEMORY
DATA
All files in memory.
[*]
CLEAR
MEMORY
Y-C N-T
[C] to clear file data,[T] to quit.
[C] or [T]
Z1.0
RESET
SALES
DAILY
Return to Z mode.