Digi ShowBox Setup Guide (90000898 Rev. C) – Page 18
EN 55024
Test
Specification
EN55024
Requirement
Electrostatic
Discharge
EN61000-4-2
+2,+4 kV direct contact
+2,+4 kV and +8kV air
(insulated surfaces)
+2,+4 kV(HCP&VCP)
indirect
Radiated Immunity EN61000-4-3
3 V/m, 80Mhz-1000Mhz,
amp mod 1kHz sine wave
at 80%
Electrical Fast
Transient Burst
EN61000-4-4
+0.5kV,+ 1kV (A/C)
+0..5kV (I/O)
Surge
EN61000-4-5
+0.5kV,+ 1kV 1kV
Conducted
Immunity
EN61000-4-6
3Vrms, .150Mhz to
80Mhz, amp mod. 1kHz
wave at 80%
Magnetic Immunity EN61000-4-8
1 A/m Not Applicable
Voltage Dips &
Interrupts
EN61000-4-11
>95%10ms, 30%@500ms
& >95%@5sec reduction
at rated voltage
European Contact
Digi International
Joseph-von-Fraunhofer Str. 23
44227 Dortmund, GERMANY
49-231-9747-0
UL/CSA Safety Information
This device complies with the requirements of following safety standards below:
UL 1950, 3rd edition
CSA No. 950
Quality Manager
Austin, Texas