Digi MIL-120A Скачать руководство пользователя страница 2

 

Install Guide

Model: MIL-120A

2

 

I n s t a l l a t i o n

 

Do the following to install the MIL-120A:

1. Attach a UTP cable from the network to the MIL-120A's RJ-45 port

2. Attach a T-type BNC connector from the network cabling to the BNC 

connector

3. Connect the power adapter's cord from the power source to the unit

 

Note:

 

Use shielded twisted pair (CAT 5) cabling for CISPR 22 B installation.

 

L i n k   Te s t

 

The MIL-120A provides a 

 

Link

 

 test function, which is a 10BASE-T standard. The 

MIL-120A ships with the 

 

Link

 

 function test “enabled”—only pin one jumpered 

with a jumper block. This allows the LEDs to illuminate when there are links.

 

D i s a bl i n g   L i n k

 

To disable the 

 

Link

 

 test:

1. Use a Phillips-head screwdriver to remove the four Phillips-type screws 

located on the sides of the unit

2. Remove the BNC nut and its washer

3. Slide the housing off, over the BNC connector

4. Locate the two-pin 

 

Link

 

 jumper (Figure 1)

5. Place the jumper block onto both pins

6. Reassemble the unit (reverse steps 1 through 3)

 

Note:

 

The MIL-120A operates in a “StarLAN-10” environment when 

 

Link

 

 is disabled. Only the 

 

Power

 

 and 

 

Link

 

 LEDs Illuminate.

 

Figure 1.Link and DIP Switch Locations

Link Test 
Enabled

1   2

DIP Switch

LINK

Содержание MIL-120A

Страница 1: ...g information Installation on page 2 Link Test on page 2 Disabling Link on page 2 Diagnostic LEDs on page 3 Configuration on page 3 RJ 45 Pinouts on page 3 Legal on page 4 12 20VAC Ethernet IEEE 802 3 FCC PART 15 CLASS A COMPLIANT THIN TWIST Model MIL 120A COAX to 10BaseT CONVERTER COL TP RCV TP LINK POWER COL CX RCV CX ...

Страница 2: ...he Link function test enabled only pin one jumpered with a jumper block This allows the LEDs to illuminate when there are links Disabling Link To disable the Link test 1 Use a Phillips head screwdriver to remove the four Phillips type screws located on the sides of the unit 2 Remove the BNC nut and its washer 3 Slide the housing off over the BNC connector 4 Locate the two pin Link jumper Figure 1 ...

Страница 3: ...lude If the MIL 120A is connected to the end of a multi node segment without a T connector and terminator enable the 50 ohm resistor by Placing switch 1 UP and Placing switch 2 DOWN If the MIL 120A is connected to a single node without a T type connector and terminator on a COAX cable of less than one meter s length Place both switches 1 and 2 in the DOWN position Note For this configuration you d...

Страница 4: ... serial number and rev Date of purchase Vendor or place of purchase Reach Digi Technical Support at 408 744 2751 Or E mail at sun tech dgii com Address 1299 Orleans Drive Sunnyvale CA 94089 Voice 408 744 2775 Fax 408 744 2793 E mail info dgii com Five Year Limited Warranty Digi International warrants to the original consumer or purchaser that each of its products and all components thereof will be...

Отзывы: