background image

HR4420/i/p Installation Guide 

Status Indicators 

The status indicators operate as follows: 

ON 

Illuminates steady red when power is applied. 

LAN 0, 1, 2, 3 

Illuminate  steady  when  there  is  a  network  connection  to  the 
associated  LAN  port  and  flash  when  data  is  transmitted  or 
received. 

3G/GSM: 
NET, SIM, 
DAT 

These indicators operate as follows: 

NET

 

–  Illuminates  green  when  a  wireless  network  has  been 

detected. 

SIM

 

– Illuminates green when a valid SIM card is installed in the 

unit. 

DAT

 

– Flashes green when data is being transmitted or received. 

SIGNAL 

The  three  indicators  labelled  SIGNAL  illuminate  to  indicate  the 
wireless signal strength as follows: 

None illuminated 

< -113 dBm (effectively no signal) 

1 LED illuminated 

>= -112 dBm and <= -87dBm (weak) 

2 LED‟s illuminated 

>= -86dBm and <= -71dBm (medium) 

3 LED‟s illuminated 

>= -70dBm and <= -51dBm (strong) 

ISDN: 
D, B1, B2 

On the HR4420i, these indicators operate as follows: 

D

 

–  Illuminates  green  when  the  unit  is  connected  to  an  ISDN 

network and the D-channel signalling layer is active. 

B1

 

–  Illuminates  green  when  ISDN  B-channel  1  is  active  and 

flashes  when  data  is  being  transmitted/received  over  this 
channel. 

B2

 

–  Illuminates  green  when  ISDN  B-channel  2  is  active  and 

flashes  when  data  is  being  transmitted/received  over  this 
channel. 

PSTN: 
OH, CD, DAT 

On the HR4420p, these indicators operate as follows: 

OH

 

– Illuminates green when the modem has gone off-hook. 

CD

 

– Illuminates green when the unit has connected to a remote 

modem and asserted the Carrier Detect signal at the serial port. 

DAT

 

–  flashes  green  when  the  unit  has  connected  to  a  remote 

modem and data is being transferred. 

 

Содержание HR4420

Страница 1: ...H H R R 4 4 4 4 2 2 0 0 i i p p 4000 Series Routers Wireless GPRS EDGE UMTS HSDPA HSUPA router switch Installation Guide ...

Страница 2: ...E Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for d...

Страница 3: ...ference or create an electric shock hazard and will void your warranty 4 Do not attempt to repair the products they contain no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 The HR4420 HR4420i and HR4420p are designed for indoor use only and should be used in an environment that is suitable f...

Страница 4: ...tential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failure to obs...

Страница 5: ...nc serial ports 25 way D 2 x USB 2 0 host ports 2 x SIM card sockets Several combinations of wireless ISDN and PSTN connectivity are available depending on the model Note You will not be able to use the router for remote communication until you have subscribed to a suitable wireless network service Package Contents When you receive the router carefully unpack it and check the contents These should...

Страница 6: ...ike a modem or via the built in Web interface We recommend that you use the Web interface whenever possible In addition to many standard LAN and Internet protocols such as PPP HR series products provide a combination of powerful but easy to use configuration management and diagnostic tools This makes them simple and cost effective solutions for migrating existing terminal or telemetry equipment wh...

Страница 7: ...LED illuminated 112 dBm and 87dBm weak 2 LED s illuminated 86dBm and 71dBm medium 3 LED s illuminated 70dBm and 51dBm strong ISDN D B1 B2 On the HR4420i these indicators operate as follows D Illuminates green when the unit is connected to an ISDN network and the D channel signalling layer is active B1 Illuminates green when ISDN B channel 1 is active and flashes when data is being transmitted rece...

Страница 8: ...unit to 10 100 BaseT LANs using the 2 metre STP Shielded Twisted Pair cable supplied or a suitable alternative These ports are auto sensing for speed and wiring straight through or cross over To comply with EMC requirements they should not be used with non STP cable GSM 3G ANTENNA This SMA connector is used to fit the GSM 3G stub aerial supplied with the unit A range of alternative antennas are av...

Страница 9: ...ply a range of suitable aerials Important If you are going to be using the Sar OS Connection Wizard to configure the unit s Ethernet port and also connect it to your GSM 3G network skip this section and proceed to Configuration Step 1 Installing the SIM card s The router incorporates two separate SIM card holders so that if your application demands it you may install SIM cards for two different ne...

Страница 10: ...ith external antennas as the spacing between the two antennas is critical Step 3 Connecting the LAN cable Plug one end of one of the supplied 2 metre CAT5 cable into the RJ45 socket labelled LAN 0 Plug the other end into the LAN socket on your PC or notebook Step 4 Connecting the serial cable For connection to a serial terminal device connect the 25 way D plug on the serial cable provided to the S...

Страница 11: ...P address for the LAN 0 port is 192 168 0 99 with a Class C subnet 255 255 255 0 Setting your PC s IP address to one on the same subnet 192 168 0 will enable you to connect to the unit s Web interface You will then be able to configure the unit manually Step 1 Install the Connection Wizard Download the connection wizard from the Digi website and install the software on your PC Step 2 Run the Wizar...

Страница 12: ...50 900 1800 1900 MHz EDGE E GPRS multi slot class 10 max 236 8 kbps downlink mobile station class B modulation and coding scheme MCS1 9 HR4420i WAN interfaces As HR4420 plus Full duplex 2B D S T interface transceiver according to ITU T I 430 LAPB and LAPD support Non auto mode transparent mode extended transparent mode HR4420p WAN interface As HR4420 plus 14 4 kbps fax modem V 92 compliant backwar...

Страница 13: ...i HR4420p Part numbers 81 HR4420 SSEU 00 HR4420 81 HR4420 SSEU 01 HR4420i 81 HR4420 SSEU 02 HR4420p conform to the relevant harmonised standards EN60950 1 A11 2004 EN301489 07 v1 2 1 2002 08 EN55022 1998 EN55024 1998 A1 2001 EN301511 v9 0 2 following the provisions of Council Directive 1999 5 EC on radio equipment and telecommunications terminal equipment and the mutual recognition of their confor...

Отзывы: