background image

DS-425 Service Manual --- V1.04 

 
e.g.) With Header code and weight stability code 

Net weight =-1,2340 Tare weight = 0,450 and weight is stable 

Null 

CR 

CR 

4

0

0

0

CR

LF 

Note 1): The data format consists of (header code), minus/plus sign, numeric data and 

decimal point. If weight data is minus, -(2DH) is added after header data. If 

weight is positive data, 0(30H) is output. 

Note2): The data is aligned from right side. 

Note3): When weight is over the capacity, the following data is output: 

 

0OV00000CR4???????CRLF (With Header Code) 

Note4): By specification setting, the decimal point can be set to period (2EH) or comma 

(2CH). 

4.4. Communication Method 

Communication method can be set as Stream Output, Manual and Command. 

4.4.1. Stream Output (Continuously Output) 

Data will output to PC side continuously. Please also define the contents of data on 

SPEC 03 bit 0&1) is not effective. 

4.4.2. Manual Command 

Data will output when 

 key pressed, user may select to output data right away or 

hold the command until weight stable by specification setting. If weight is not stable 

within certain interval, Error message “ERR C” will appear on the display. 

 
 

 

 

 PC Side                                        DS-425 Side 

 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No 

X. Seconds 

Yes

Text 

No 

Weight 

Stable?

Manual Command 

 
 
 

Yes

 
 

Time Out 

 
 

04 RS-232C Protocol                                                                                               Page No. 17 

 

Содержание DS-425

Страница 1: ... 1998 2nd December 1998 3rd April 2001 4th January 2002 Shanghai Teraoka Electronic Co Ltd Technical Service Dept Ting Lin Industrial Development Zone Jin Shan District Shanghai P R China 201505 Tel 86 21 5723 4888 Fax 86 21 5723 9330 E mail steservice digi scale com ...

Страница 2: ...unt and A D Count Display 8 2 8 Specification List V1 04 8 2 9 System Display Information 10 3 Main Operation 3 1 System On 11 3 2 One Touch Tare 11 3 3 Digital Tare Operation 11 3 4 Gross Net Display Toggle 12 3 5 Weight Unit Conversion 12 3 6 Counting Operation 12 3 7 Set Point Setting 13 3 8 Set Point Alarm Function 14 4 RS 232C Protocol 4 1 Communication Specs 16 4 2 Communication Text Command...

Страница 3: ...DS 425 Service Manual 1 General Specification 1 1 Overall Dimension 1 2 Display Panel 01 General Specification Page No 1 ...

Страница 4: ...PCS Interface RS 232 OPTIONAL Load cell 300g K Type 600g 30Kg N Type Mechanical Detail Housing DS 425W DS 422 Keyboard Physical Dimension L 321 W 256 H 80 mm Platter Size 105mm x 160mm 300g 205mm x 250mm 600g Upwards 1 4 Operation Condition Power Source AC 220V 10 15 50HZ 60HZ Factory Set Temperature 0 C to 40 C Humidity 85 RH Microcomputer Atmal AT89C52 8bit Display Device Liquid Crystal Display ...

Страница 5: ...de Enter Used for storing the data Shift Used to change digital position INC 1 Used for increase data value when digit blinking 2 Switch the weight unit 1 6 2 Display a Layout b Indicators Indicator Function 0 Light when display is zero and stable NET Light when displays net weight Light when weight is stable U C Light when working in counting mode SAF Set point ALAME Mode is ON and during Fill Ap...

Страница 6: ...ight display Excute tare Tare 0 0000 kg B B Net display Load more weighing 1 0000 kg B B Remove all items 1 2220 kg B B B Minus tare weight Tare clear Tare 0 0000 kg B B Weighing mode Note This operation is based on No Auto TARE CLEAR SPEC10 BIT1 0 3 3 Digital Tare Operation Indication Flag B Bright S Sparkling 1 ZERO 2 NET 3 STD 4 U C 5 SAF 6 SAC 7 S1 8 S2 9 S3 10 S4 Indicator Operation Key Weigh...

Страница 7: ... 6 SAC 7 S1 8 S2 9 S3 10 S4 Indicator Operation Key Weight 1 2 3 4 5 6 7 8 9 10 Remarks Weight Stable 0 0000 k g B B Weighing mode Load weight eg 0 6000kg 0 6000 k g B Convert INC 1 3225 lb B Pound display Convert INC 21 165 o z B Ounce display Convert INC 0 6000 k g B Basic unit display Remove items 0 0000 k g B B Weighing Mode Note This operation is available when SPEC15 0100 or 1100 only 3 6 Co...

Страница 8: ... as point 1 setting 2 Confirm Enter SET 3 kg Point 2 saved 3 Confirm Enter 0 0000 kg B Set value 3 Value Change Shift INC 0 0100 kg B Same procedure as point 1 2 setting 3 Confirm Enter SET 4 kg Point 3 saved 4 Confirm Enter 0 0000 kg B Set value 4 Value change Shift INC 0 0100 kg B Same method as above 4 Confirm Enter 0 0000 kg B B Point 4 saved and back to weighing mode 4 Note 1 The indicators S...

Страница 9: ... Target Zero Set point 1 Set point 2 Set point 3 Set point 4 Full Span Note continuous slow alarm continuous fast alarm 3 8 2 Weight Check Method Operator places item on the platter and check confirm whether the weight of the item is within allowable error range Basically the allowable error range can be defined via the setting of 2 set points For example set point 2 and set point 3 And also you c...

Страница 10: ...0150 kg B B B Fast alarm start Load 0 0150kg 0 0300 kg B B B B Slow alarm start Load 0 0150kg 0 0450 kg B B B B B Fast alarm start Load 0 0150kg 0 0600 kg B B B B B B Alarm off Remove all item 0 0000 kg B B B Press Enter Enter 0 0000 kg B B B Weight check method Load 0 0150kg 0 0150 kg B B B Fast alarm start Load 0 0150kg 0 0300 kg B B B B B Slow alarm start Load 0 0150kg 0 0450 kg B B B B B B Fas...

Страница 11: ...ion setting Header Code Selection SPEC02 Bit 0 Weight Stability Selection SPEC02 Bit 1 4 3 1 Without header code and weight stable code Total 17 Bytes Net Weight CR Tare Weight CR LF 7 Byte 1byte 7 Byte 1 Byte 1 Byte 4 3 2 Without header code and with weight stable code Total 19 Bytes Stable status CR Net Weight CR Tare Weight CR LF 1 Byte 1 Byte 7 Byte 1byte 7 Byte 1 Byte 1 Byte 4 3 3 With header...

Страница 12: ... Note4 By specification setting the decimal point can be set to period 2EH or comma 2CH 4 4 Communication Method Communication method can be set as Stream Output Manual and Command 4 4 1 Stream Output Continuously Output Data will output to PC side continuously Please also define the contents of data on SPEC 03 bit 0 1 is not effective 4 4 2 Manual Command Data will output when key pressed user ma...

Страница 13: ...uest signal the weight data will be transferred immediately or hold the command till weight stable If weight cannot be stable within the certain interval set by specification DS 425 will transmit NAK 15H to PC Note If ACK signal is sent to DS 425 during digital tare or re zero operation NAK signal will be sent to PC PC Side DS 425 ACK No Weighing Mode Yes Yes NAK Yes X Seconds Stable NAK Data No N...

Страница 14: ...New A D Cover 5 2 Block Diagram A D BLOCK STB 0054 3 LOADCELL BLOCK INTERNAL MAIN BOARD BLOCK STB 0052 4 WITH OPERATE DISPLAY POWER BLK AX 5 3 Electronic Connection Diagram RS 232 Interface Operator Display Display Driver Keyboard Main CPU AT89C52 MCS51 A D Block STB 0052 3 Scale Internal Block Interface Driver Power Block AC Input 05 Hardware Specification Page No 19 ...

Страница 15: ...DS 425 Service Manual V1 04 5 4 Circuitry Diagram Please See Attached Pages for DS 425 Circuitry Diagram Technical Service Dept Shanghai Teraoka Electronic Co Ltd 05 Hardware Specification Page No 20 ...

Отзывы: