background image

Transport WR Series Installation Guide 

13 

 

Select  the  proper  carrier  and  start  the  provisioning  script.  Manual  provisioning  can  be 
selected  if  you  have  been  provided  with  the  proper  parameter  from  your  carrier  (MSN< 
MSID, SPC, etc.). 

 

Follow prompts to save the configuration to flash memory. 

 

Step 3 

– Verify Cellular Connection 

Verify the mobile connection is established and view the mobile IP address by going to: 

Diagnostics -> Status

 -> 

PPP

 -> 

PPP 0-4

 -> 

PPP 1

 -> View 

 

Viewing the Event Log can also be used to view the connection status. 

Diagnostics -> Event Log 

 

Step 4 

– Test Mobile Connection 

 

Depending on the wireless plan being used, you should be able to perform a test to a 
remote host or browse the Internet. By default, the Digi Transport should have issued your 
workstation an IP address of 192.168.1.100 via DHCP.  DHCP will pass the proper default 
gateway and DNS server information. Verify this on the workstation by using the “ipconfig” 
command. If the workstation does not obtain an IP address of 192.168.1.100 enter 
“ipconfig /renew” in your workstation‟s command window. 
 
A simple test for most Internet connected plans is to open a browser and connect to a web 
site. For non-Internet connected plans consult your IT administrator and/or wireless carrier 

Содержание Digi TransPort WR

Страница 1: ...T T r r a a n n s s p p o o r r t t W W R R Cellular Routers Wireless WAN router switch Installation Guide ...

Страница 2: ... disposal instructions The WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed wit...

Страница 3: ...he unit contains no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 Products in the Transport WR family are designed for indoor use only and should be used in an environment that is suitable for computers and other electronic equipment 6 Ports that are capable of connecting to other apparatus ...

Страница 4: ...doubt about potential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems ...

Страница 5: ...J45 connector 1 x USB 2 0 host port 2 x SIM sockets GSM models 1 x Wireless WAN interface varies with model All models may also be purchased with one of a number of hardware options which are listed in the section entitled Optional Features below Package Contents When you receive the router carefully unpack it and check the contents These should include Item System Unit 5V DC 3A power supply Insta...

Страница 6: ...ating existing terminal or telemetry equipment which use wired networks PSTN ISDN etc to wireless operation 1 1 Front Panel Features The front panel of the unit incorporates the USB host connector 10 LED indicators and the two SIM card holders as shown in the following illustration USB Host Connector The USB host connector may be used to connect compatible USB 2 0 client devices such as memory sti...

Страница 7: ...ength as follows None illuminated 113 dBm effectively no signal 1 LED illuminated 112 dBm and 87 dBm weak 2 LED s illuminated 86 dBm and 71 dBm medium 3 LED s illuminated 70 dBm and 51 dBm strong DTE Illuminates steady if a terminal is connected to the ASY0 serial port and the DTR signal is on Flashes when data is transmitted or received SIM Sockets On the Transport WR41 E H and U the two sockets ...

Страница 8: ...ceiver supports diversity antenna capability to improve performance and are there supplied with two stub antennas One of these should be fitted to this connector and the other to the ANT AUX connector Note Stub antennas are provided as standard but a range of suitable alternative for use in different applications may be purchased separately W WAN ANT AUX This SMA connector is used on the Transport...

Страница 9: ...eatures Routers are available with a variety of hardware options including 1 x ASY Provides an additional asynchronous serial port using a 25 way D connector 3 x ASY Provides three additional asynchronous serial ports using RJ45 connectors 1 x SYN Provides an X 21 RS422 RS232 synchronous serial port using a 25 way D connector 1 x GPS Provides GPS geo location capability 1 x ISDN BRI Provides an IS...

Страница 10: ...ut in some circumstances it may be necessary to use a window mounted or magnetically mounted antenna with an extended cable to allow the antenna itself to be positioned to provide the best possible signal reception Digi International can supply a range of suitable antennas Step 1 Installing the SIM card GSM models only The router incorporates two separate SIM card holders so that if your applicati...

Страница 11: ...ntennas supplied as standard e g two wall mount antennas the separation between the two should be no less than the separation between the two associated connectors on the rear panel of the unit Step 3 Connecting the LAN cable Plug one end of one of the supplied Ethernet cable into the RJ45 socket labelled LAN 0 Plug the other end into the LAN socket on your PC or notebook Step 4 Connecting the ser...

Страница 12: ...s to one on the same subnet 192 168 1 will enable you to connect to the unit s Web interface Step 1 Connect to the Web Interface Open a browser and connect to the Web interface by connecting to http 192 168 1 1 It is recommended to change the default username and password on the device Default Username username Default Password password This setting can be changed by going to Configuration Securit...

Страница 13: ...PPP username and password they you can skip this next step Configuration Interfaces PPP PPP 0 4 PPP 1 Standard Enter the PPP username password and confirm password Click OK Follow prompts to save the configuration to flash memory Transport WR41 C CDMA Devices Start the CDMA Provisioning by going to Configuration Interfaces Mobile W WAN Module CDMA Provisioning ...

Страница 14: ...s Diagnostics Event Log Step 4 Test Mobile Connection Depending on the wireless plan being used you should be able to perform a test to a remote host or browse the Internet By default the Digi Transport should have issued your workstation an IP address of 192 168 1 100 via DHCP DHCP will pass the proper default gateway and DNS server information Verify this on the workstation by using the ipconfig...

Страница 15: ...r greater description on all the features and settings available on the device there is a comprehensive Reference Guide available on the Digi Support website www digi com Advanced Configuration VPN Configuration VPN Routing Configuration Routing Firewall Configuration Security Firewall Users Configuration Security Users Alarms Configuration Alarms VRRP Configuration Interfaces Eth x Configure Seri...

Страница 16: ...link MO 0201 850 1900 2100 Rx diversity MHz Quad band GSM 850 900 1800 1900 MHz EDGE E GPRS multi slot class 12 max 236 8 kbps downlink mobile station class B modulation and coding scheme MCS1 9 GPRS multi slot class 12 mobile station class B PBCCH support coding schemes CS 1 4 WR41 U GSM GPRS EDGE UMTS HSDPA HSUPA modem HSUPA mode 2 Mbps Category 5 HSDPA 1 8 Categories 1 4 11 and 12 HSDPA 3 6 Cat...

Страница 17: ... IS 856 A Forward link up to 31 Mbps Reverse link 1 8 Mbps 1 x EV DO Revision O IS 85L Forward link up to 2 4 Mbps Reverse link 153 6 Kbps 1 x RTT IS 2000 Forward and reverse link speeds up to 153 6 Kbps USB ports One USB 2 0 Full speed Host 12 Mbits second maximum throughput Ethernet interface 10 100Base T auto sensing auto MDI MDX RJ45 Serial interface Asynchronous RS232 compatible RJ45 ...

Отзывы: