22
7.4. Internal Count And A/D Count Display :
If the SPEC 25, bit 2 is set, then the
[SPAN]
Switch must be "ON" to enter this mode.
1
Enter
[0] [0] [9]
while depressing the
[REZERO]
Key.
Unit Weight Window
will display
the Internal Count and the
Quantity Window
will display the A/D Count.
2
Press
[MODE]
Key to exit from Program Mode to Weighing Mode.
3
Depressing the
[SPAN]
Switch returns scale to the Weighing Mode.
7.2. Spec 141 Setting
Spec 141 Setting:
Spec 141(Customer Specifications) can be accessed from the weighing mode.
1.
Enter
[1][4][1]
while depressing the
[REZERO]
key.
2.
[
+
+
+
+
]
key increases to the next SPEC number and also stores temporarily the SPEC data in the RAM location.
3.
Enter 1011 as the new value for SPEC01 using the
[Numeric]
keypad
4.
[C]
key
clears the
[Numeric]
entry.
5.
[
+
+
+
+
]
key increases to the next SPEC number.
6.
[
−
−
−
−
]
key decreases to the previous SPEC number.
7.
[
−
−
−
−
]
key decreases from SPEC 01 to SPEC 00.
8.
[
−
−
−
−
]
key decreases the SPEC number from SPEC00 to SPEC18
9.
[
❋
]
stores the new SPEC values to the NOV-RAM and exits from the SPEC setting mode.
10.
Press
[MODE]
key to escape from maintenance mode to weighing mode.
7.3. Spec 142 Setting
Spec 142 Setting:
To access the Spec 142 (W & M Spec) mode the
[SPAN]
Switch must be "ON".
The rest of the procedure is the same as Spec 141 setting.
See page 10 for location of the span switch
1
Depress the [
SPAN]
Switch. The S-On message comes on.
2
Enter
[1][4][2]
while depressing the
[REZERO]
key.
3
[
+
+
+
+
]
key increases to the next SPEC number and also stores temporarily the SPEC data in the RAM location.
4
Enter, (example, 1011) as the new value for SPEC21 using the
[Numeric]
keypad
5
[C]
key
clears the
[Numeric]
entry.
6
[
+
+
+
+
]
key increases to the next SPEC number.
7
[
−
−
−
−
]
key decreases to the previous SPEC number.
8
[
−
−
−
−
]
key decreases from SPEC 21 to SPEC 20.
9
[
−
−
−
−
]
key decreases the SPEC number from SPEC20 to SPEC36
10
[
❋
PROG]
key
stores the new SPEC values to the NOV-RAM and exits from the SPEC setting mode.
11
Press
[MODE]
Key to exit from Spec Setting mode. The display shows S-On indicating that the
[SPAN]
Switch is ON.
12
Depressing the
[SPAN]
Switch returns scale to the Weighing Mode.