SPEC 17: 

Print Human Readable number under bar-code (Tare Weight) 

 

  

Y: 

Allow 

N: 

Inhibit 

 

 

SPEC 18: 

Print bar-code of gross weight 

 

  

Y: 

Allow 

N: 

Inhibit 

 

 

SPEC 19: 

Print Human Readable number under bar-code (gross weight) 

 

  

Y: 

Allow 

N: 

Inhibit 

 

 

SPEC 20: 

Print bar-code of net weight 

 

  

Y: 

Allow 

N: 

Inhibit 

 

 

SPEC 21: 

Print Human Readable number under bar-code (net weight) 

 

  

Y: 

Allow 

N: 

Inhibit 

 

 

SPEC 22: 

Label Print  

 

  

ALL 

All operation 

OUT 

Shipping Operation 

IN 

Receiving Operation 

N/A 

Non-add Operation 

I&O 

Receiving and Shipping Operations 

NON 

No Printing 

 

 

SPEC 23: 

Print Title of task 

 

  

Y: 

Allow 

N: 

Inhibit 

All manuals and user guides at all-guides.com

Содержание DC-150

Страница 1: ...del DC 150 Edition Month Year 3rd August 1996 TERAOKA SEIKO CO LTD 13 12 Kugahara 5 chome Ohta ku Tokyo 146 Japan TEL 81 3 3752 2131 FAX 81 3 3752 2801 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...1 SET UP 1 All manuals and user guides at all guides com ...

Страница 3: ...arts 5 1 2b Display Keys 6 1 3 LABEL FORMAT AND LABEL SET UP 10 1 3a Specification of Labels and Receipt 10 1 3b Standard Print Formats 10 1 3c How to set paper 11 1 4 OPERATION FLOW CHART 12 2 All manuals and user guides at all guides com ...

Страница 4: ... 5kg 500g 5kg NO NO DC 152D 518KB 1kg 5kg 1kg 10kg DC 153DI DC 153DI 63KB 1lb 5lb 1lb 10lb X YES DC 153DI 518KB 2 5lb 10lb 2 5lb 25lb DC 152CFX DC 152CI 64KB no scale YES DC 152CI 518KB 2 SCALE SPECIFICATIONS WEIGHING DEVICE LOAD CELL DISPLAY DEVICE Fluorescent Display INTERNAL RESOLUTION 1 500 000 DISPLAY RESOLUTION 1 10 000 or 1 5 000 or 1 2 500 3 MEMORY SPECIFICATIONS 64kb STANDARD for 385 ITEM...

Страница 5: ...CALE 2 5 DISPLAY SPECIFICATION 20 DIGITS 5 X 7 DOTS Fluorescent Display WEIGHT 6 DIGITS UNIT WEIGHT 5 DIGITS QUANTITY 6 DIGITS 6 PRINTER THERMAL PRINT 0 135 mm x 0 135 mm Square Dot 448 Dots Line 7 ELECTRICAL REQUIREMENT OPERATION VOLTAGE 100 117 220 230 240 Vac OPERATING FREQUENCY 50 or 60Hz POWER CONSUMPTION 15Wz 8 ENVIRONMENT OPERATING TEMPERATURE 0 40C 4F 104F OPERATING HUMIDITY 15 TO 85 RH 9 ...

Страница 6: ... A MODEM FL 1 2 SCALE 1 B SET POINT OUTPUT 3 SCALE 2 C PEN REWAIND SCANNER 4 DISPLAY WINDOW D IBM KEY BOARD 5 OPERATION KEYS E FORCE BALANCE 6 PRINTER F EXTERNAL SCALE I F 1 G EXTERNAL SCALE I F 2 5 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 7: ...UFF Sample size is too small to calculate RECOMP Unit weight may be recalculated by pressing PIECES key MEMORY An accumulated total is in memory IN Quantities being added to inventory and movement data OUT Quantities being removed to inventory and movement data JOB NODULE 1 8 JOB instruction is in the process of Auto job operation 9 16 9 16 will flash on and off 6 All manuals and user guides at al...

Страница 8: ...E Toggle between modes Exit modes without saving data AUTO MANUAL AUTO MANUAL Toggle between Auto Job Operation and Manual Operation in Operation mode Back to the precious screen in programming data LOT NO LOT NUMBER Enter the key in data to LOT No in OPR mode RE ZERO RE ZERO Eliminate weight from the weight dispaly with no tare and causes it to show a true zero TARE TARE Enter a tare value into t...

Страница 9: ...e to accumulate UNIT WEIGHT CODE RETRY CODE Call ITEM data from memory file Reprint the same label without saving inventory total in OPR mode Print TEST LABEL TOTAL LABEL in programming FREE FORMAT ENTER ENTER Print total accumulation in OPR mode Enter set up choices and advantages to next choice Then at the end of choices store the data into memory files A Z ALPHABET PLUS PLUS MINUS SLASH Key alp...

Страница 10: ...tion is available in LB version Print TEST LABEL ITEM LABEL in programming FREE FORMAT SHIFT DOWN SHIFT DOWN Change the key functions to the lower line of Alphabet keys SHIFT UP SHIFT UP Change the key functions to the special charactors in the upper line of Alphabet keys 9 All manuals and user guides at all guides com ...

Страница 11: ...free label formats The format can be selected in PRINT SPEC in maintenance mode Also 3 types of labels can be printed by the following applications in operation mode ITEM LABEL Issued in single operation in OPERATION MODE TOTAL LABEL Issued in multiple operation in OPERATION MODE GROSS LABEL Issued in gross weight operation in OPERATION MODE NOTE Refer to APPENDIX Ι to see the sample of standard f...

Страница 12: ...eeln with the same direction as drawing until it stops 9 Set the label and receipt switch on the left side of label cassette LEFT label RIGHT receipt 10 Slide label cassette back into the main unit along with the metal shaft under the thermal head block 11 Close the thermal head by pushing the top of thermal head 12 Close the side panel and put the front panel of printer back 13 Depress FEED Key t...

Страница 13: ...at Copy Free Format Setting Max 2 Format Shelf Location Format Setting Shelf Location Limit Setting Address Setting CHECK MODE Memory Contents Check Inventory Data Check Shelf Location No Check MAINTENANCE MODE SPEC Setting Display Report Printing Outside Apparatus Others Deletion of programmed data Free format I D data Print Adjustment Auto job operation number setting Saving or loading data with...

Страница 14: ...13 2 PROGRAM MODE All manuals and user guides at all guides com ...

Страница 15: ... code and Item Data 28 2 3 DATE TIME SETTING 30 2 4 SET POINT OUTPUT SETTING 31 2 5 TITLE CONTENTS SETTING 33 2 5a Defult data list 33 2 5b Programming Title Contents 34 2 5c Delete Title Contents Data 35 2 6 PRE PRINT DATA SETTING 36 2 6a Programming Pre print Contents 37 2 6b Delete Pre Print Contents Data 38 2 6c Print Position Character Size of Pre Print Data 39 2 6d Programming Print Position...

Страница 16: ...r code 47 2 8g Programming Screen 48 2 8h Function Key 49 2 8i Programming Operation 50 2 8 j Programming Procedure 56 2 9 SHELF LOCATION LABEL SETTING 58 2 9a Label Size 58 2 9b Programmable Item Data for Shelf Location Label 58 2 9c Data Type 58 2 9d Printing Position 59 2 9e Label Angle And Bar Code Angle 59 2 9f Character Size and Magnifications 59 Height of Bar code 59 2 9g Programming Screen...

Страница 17: ...ELF LOCATION LIMIT SETTING 63 2 10a Genral Explanation for SHELF LOCATION No 63 2 10b Shelf Location Limit 64 2 10c Programming Operation 64 2 11 ADDRESS CONTENTS SETTING 65 2 11a Programming Operation 65 2 6b Delete Pre Print Contents Data 67 All manuals and user guides at all guides com ...

Страница 18: ... O 1 2 3 4 5 6 7 8 2 Enter PRG mode by depressing ENTER key PRG ID CODE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select each file in Programming Mode by depressing TARE or UNIT WEIGHT key PRG FREE FORMAT SET Refer to 2 1b Data files and Function List Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter the displayed mode by depressing ENTER key F F FREE FORMAT 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8...

Страница 19: ...lue 2 5 Title Contents File Programming text massage title on formats 2 6 Preprint data File Programming text and position of Pre print data 2 7 Copy Format Function Copying a standard format to Free format 2 8 Free Format File Programming Free format 2 9 Shelf Location Format File Programming Shelf Location Format 2 10 Shelf Location Limit File Setting Shelf Location Limit 2 11 Address Data File ...

Страница 20: ...ed data TARE and UNIT WEIGHT key To select the headings in loop routines To move the cursor to left right when there are purl cursors in a display PLUS and MINUS key To select the data when cursor of triangle indicator is blinking CURSORS The cursors appear when programming data The cursor shows not only the maximum number of digits but also the characteristic of the entering data 1 Light cursor T...

Страница 21: ... to 2 7 Setting Shelf Location Limit Inventory After you set up the initial quality of stock the data is renewed along with receiving or shipping value The accurate quantity of stock in your warehouse can be handled with this number Threshold Threshold is the ideal quantity of stock By comparing with the actual quantity of inventory lack or excess of stock can be checked Set Point Output Set Point...

Страница 22: ...Digits Numeric data Decimal Point Parts No 32 Digits Alpha Numeric Data Period Space Parts Name 32 Digits Alpha Numeric Data Period Space Shelf Location No 8 Digits Alpha Numeric Data Inventory 8 Digits Numeric data and Minus Threshold 8 Digits Numeric data Set Point 7 Digits Numeric Data and decimal Point Scale No 1 Digit 0 3 Auto Job No Shipping 1 Digit 1 5 Auto Job No Receiving 1 Digit 1 5 Auto...

Страница 23: ...ess SHIFT DOWN key then A PART NO key within 3 seconds 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 PART NAME ENTRY 6 Enter Parts Name Ex Capacitor 1211E1 16 C A P A C I T E R 1 2 1 1 E 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depress SHIFT DOWN key then B PART NAME key within 3 seconds 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 When entering a special character above alpha...

Страница 24: ... 7 8 11 Depress SHIFT DOWN key then D INVENT key within 3 seconds 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Threshold Entry 12 Enter Threshold data Ex 5100 Pcs 4 5100 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 13 Depress SHIFT DOWN key then E TH HOLD key within 3 seconds 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 you cannot assign the data to the location number the entered va...

Страница 25: ...3 4 5 6 7 8 17 Enter Set Point 2 and depress then F SETPOINT key S P 200 250 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 18 Press F SETPOINT key 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Scale No Entry 19 Enter Scale No Ex Scale 1 1 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 20 Depress SHIFT DOWN key then G SCALE key within 3 seconds 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 Th...

Страница 26: ... 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 DIGITAL TARE 23 Enter Tare Weight value by numeric keys Ex 0 0120kg 6 0 0120 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 24 Depress TARE key 2 0 0120 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 Auto Job no can be selected from 5 patterns which are programmed in Maintenance Mode Auto Job no for shipping and non add operation can be selected with the sam...

Страница 27: ...y Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 28 Add the required pieces more and press PIECES key again 0 0270 0 9970 27 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 The unit weight value should be Unit Weight 1 000 Note 2 If using a sample of 10 pcs press PIECES key without entering a number of sample Note 3 To have accurate unit weight calculation the sample weight must be more than the insuffici...

Страница 28: ...7 8 NOTE 1 When the unit weight is developed though sampling the accuracy can be improved by increasing the sample size using recomputing feature This function works only when the RECOMP sign lit After you set all the item data and ID code depress ENTER key to enter the data into MEMORY FILE The display is back to the initial screen of ID code entry All manuals and user guides at all guides com ...

Страница 29: ...ss Y key to delete the data 2 ID ENTER ID CODE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 If the entering ID code exists on ID memory file the deletion screen appears automatically Note 2 To escape from the deletion screen press N key The screen to set Item data will appear Delete Item data on ID code 1 Select ID code file in Program Mode and depress ENTER key ID ENTER ID CODE Z S N K 1 2 3 I ...

Страница 30: ...t the item data to delete Depress SHIFT DOWN then B key P N A C A P A C I T O R 1 2 1 1 E 1 Ex Parts Name Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Press CLEAR key to enter the deletion screen D E L C A P A C I T O R 1 2 1 1 E 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Press Y key to delete 0 0000 0 9917 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 All manuals and user guides at all guides com ...

Страница 31: ...ode PRG ID CODE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Select DATE TIME file with UNIT WEIGHT PRG DATE TIME Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press ENTER key D T 1 8 0 6 9 6 2 0 3 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter date and time Ex July 20 1996 PM 19 56 D T 2 0 0 7 9 6 2 1 5 6 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Depress ENTER key PRG DATE TIME Z S N K 1 2 3 I R M I ...

Страница 32: ...ation of Setpoint 1 and Setpoint 2 can be selected as following in Maintenance Mode COMBINATION SETPOINT 1 SET POINT 2 Q TY Q TY of SETPOINT 1 Q TY To Stop Buzzer Recomputing Process Is Required Q TY of SETPOINT 1 WEIGHT WEIGHT of SETPOINT 1 LOW WEIGHT HIGH WEIGHT LOW WEIGHT HIGH WEIGHT LOW Q TY HIGH Q TY LOW Q TY HIGH Q TY Example Combination is Quantity Percentage Setpoint 1 2 000 Pcs Setpoint 2...

Страница 33: ...I O 1 2 3 4 5 6 7 8 5 Move the cursor to Setpoint 2 by pressing Unit Weight key S P 2 0 0 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Enter Setpoint value 2 and depress F SETPOINT key S P 2 0 0 0 8 0 0 Setpoint 2 80 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depress ENTER key PRG SET POINT Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 All manuals and user guides at all guides com ...

Страница 34: ...ng position and character size of title contents can be programmed in Free Format File Ref to 2 8 Setting Free Format 16 kinds of title contents can be programmed The maximum digits for each contents are 16 digits 2 5a Defult data list CONTENTS NO DEFAULT DATA PRINT STATUS Item Label Total Label Gross Label T 1 GROSS X X T 2 NET X X T 3 TARE X X T 4 P NAME T 5 P NO T 6 ID CODE T 7 LOT NO T 8 QTY X...

Страница 35: ...I O 1 2 3 4 5 6 7 8 Blinking Cursor 4 Select Title Contents No with and key Ex Title Contents No 3 TITLE CONTENTS N O 3 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Depres ENTER key The defult data appears T3 TARE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Enter the data Ex Title 3 Unit Weight T3 UNIT WEIGHT Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depress ENTER key to store the data into memory TITL...

Страница 36: ... No to delete Ex Title Contents No 3 TITLE CONTENTS N O 3 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depres ENTER key The defult data appears T3 TARE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Enter the deletion screen by pressing CLEAR key DEL TARE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Depress Y to delete data 1 T16 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 To escape from the deletion scre...

Страница 37: ...he fixed pre printing data such as vendor name or company motto can be printed The contents and the print position of preprint data should be programmed for printing Up to 3 contents can be printed in this area One contents can be programmed 32 digits at maximum Back paper PREPRINTING AREA 10mm All manuals and user guides at all guides com ...

Страница 38: ... ENTER key to program the Pre print Contents CONTENTS N O 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 5 Select Contents No with and key Ex Contents No 2 CONTENTS N O 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Depres ENTER key C2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Enter the data Ex Contents Teraoka Seiko 13 T E R A O K A S E I K O Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 8 Depr...

Страница 39: ...N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 4 Select Contents No with and key Ex Contents No 2 CONTENTS N O 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Depres ENTER key C2 T E R A O K A S E I K O Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Depres CLEAR key to enter the deletion screen DEL T E R A O K A S E I K O Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depress Y to delete data 1 C2 Z S N K ...

Страница 40: ... 0 0 Label Printing Direction CHARACTER SIZE Please refer to size of character and the magnification on APPENDEX II to select Character Size DISPLAY OF PROGRAMMING SCREEN C1 X 0 Y 0 S 0 M 0 Printing position X value horizontal Numeric key entry Printing position Y value vertical Numeric key entry Character size Selection from S 0 S 5 with keys Magnification of character Size Selection from M 0 M 2...

Страница 41: ... Select Print Coordinate with Unit Weight key PRE P R I N T C O O R D I N A T E Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Depress ENTER key to program the print position character size of Pre print C O O R D I N A T E N O 1 Contents Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 6 Select Contents No with and key Ex Contents No 2 C O O R D I N A T E N O 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 ...

Страница 42: ...GHT key C2 X 2 Y 10 S 2 M 0 to move cursor to right Ex Character Size S2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 11 Select character size by depressing or key C2 X 2 Y 10 S 2 M 1 Ex Magnification M1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 12 Depress ENTER key to store data C O O R D I N A T E N O 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Example Contents 1 TERAOKA S...

Страница 43: ... 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Depress ENTER key CPY ST NO 1 FR NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Select a standard format to be copied from by pressing or key CPY ST NO 5 FR NO 1 Ex Format No 5 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Move cursor to right by pressing Unit Weight key CPY ST NO 5 FR NO 1 Ex Free Format No 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 6 S...

Страница 44: ... ITEM LABEL TOTAL LABEL and GROSS LABEL The data base of one label format has all 3 type of labels When you make a new label format the format data for Item Total and Gross labels are saved as one data base In Free Format Set Up 2 Free Format can be programmed One item label total label and gross label are avaialble to be set for each Free Format number Label size should be pre set in Maintenance ...

Страница 45: ...ANTITY UNIT symbol X TYPE 1 DATE TYPE 1 TIME TYPE 1 TASK CONTENTS X TYPE 1 SUM TOTALING X X TYPE 1 SUM COUNT X X TYPE 1 GROSS WEIGHT X X TYPE 1 GROSS UNIT g lb X X TYPE 1 NET WEIGHT X X TYPE 1 NET UNIT g lb X X TYPE 1 TARE WEIGHT X X TYPE 1 TARE UNIT g lb X X TYPE 1 SEQUENCE NO DATA X TYPE 1 BAR CODE ID TYPE 3 BAR CODE PART NO TYPE 3 BAR CODE LOT NO TYPE 3 BAR CODE QTY X TYPE 3 BAR CODE TARE X TYP...

Страница 46: ... 2 TASK CONTENTS is IN OUT NON ADD 2 8c Data Type Every filed can have different characteristics therefore data can vary from label format to label format Three types of data can vary into accordance with the programming parameters By the divided types the programming procedures are explained in 2 8 Programming Free Format TO SET FOR ITEM DATA TYPE 1 TYPE 2 TYPE 3 X position Y position Character s...

Страница 47: ...ta The both values are graduated by one dot unit one dot is 0 135mm x 0 135mm Y x ITEM DATA 0 0 y X PRE PRINTING AREA 10mm label printing direction NOTE 1 The item data can not be printed on the bottom 10mm of label NOTE 2 The printing position of item data which you need not to print is to be set at the start point where X 0 and Y 0 All manuals and user guides at all guides com ...

Страница 48: ...ase y y x ITEM DATA x 0 0 y 0 0 y TERAOKA SEIKO PRE PRINT TERAOKA SEIKO PRE PRINT 0 degree 90 degree y y x x y y 0 0 0 0 TERAOKA SEIKO PRE PRINT TERAOKA SEIKO PRE PRINT 180 degree 270 degree 0 0 2 8f Character Size and Magnifications Height of Bar code Refer to the list of character size in APPENDEX II to select the combination of character size and magnifications for preprinting data Height of ba...

Страница 49: ... print the data set the printing position with 0 vale for X and Y Programming screen for data type 2 L 4 D 08 X 467 M 0 Line Number Selection from L 1 L 4 with or key The number of digits in the line Numeric key entry 0 8 Horizontal Vertical Selection Selection with or key X or Y Printing position X value or Y value Numeric key entry Character size Magnification Selection Selection with keys S or ...

Страница 50: ... Selection of height of bar code H 0 10mm H 1 15mm H 2 20mm H 3 25mm H 4 30mm Note 2 Selection of printing angle of bar code A 0 0 degree A 1 90 degree A 2 180 degree A 3 270 degree 2 8h Function Key UNIT WEIGHT key and TARE key To select item data in loop routine To move the cursor in a display PLUS and MINUS key To select data when cursor of triangle indicator is blinking AUTO MANUAL key To move...

Страница 51: ... 3 I R M I O 1 2 3 4 5 6 7 8 4 Select FREE FORMAT by depressing UNIT WEIGHT or TARE key F F FREE FORMAT 2 Ex Format no 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Depres ENTER key FM2 PRINT ANGLE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Depress ENTER key FM2 ANGLE 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Select label angle by depressing or key FM2 ANGLE 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 ...

Страница 52: ...K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note While programming print data the programmed data may be printed in test label With uins this function you can check if the print position is proper and adjust the data accordingly In the selection screen for item data such as the screen in procedure 9 press the following keys for test printing SP kg lb key Test Printing of Item Label PEICES key Test Printing ...

Страница 53: ...cursor to right ID X 52 Y 15 S 0 M 0 Ex Y value 15 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 5 Select character size by depressing or key and depress U W key to move the ID X 52 Y 15 S 2 M 0 cursor to right Ex S 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 6 Select Magnification by depressing or key ID X 52 Y 15 S 2 M 0 Ex M 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 De...

Страница 54: ... I O 1 2 3 4 5 6 7 8 5 Enter X value and press TARE key to move the cursor to left P N O L 1 D 8 X 64 S 0 Ex X value 64 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Press or key for Y value entry and press U W key to move the cursor to P N O L 1 D 8 Y 123 S 0 left Ex Y value 123 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Enter Y value and press U W key twice to move the cursor to right P N O L 1 D 8 Y...

Страница 55: ...lue Ex M 2 P N O L 1 D 8 Y 123 M 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 If you need to set the data for line 2 4 press TARE key to move cursor to line no selection and set the data as the same program procedure 11 Depress ENTER key to enter the data into the memory file FM2 PART NAME Ready for setting the next item data Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 All manuals and user guides at all ...

Страница 56: ... A 0 Ex Y value 236 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 5 Select height of bar code by depressing or key and depress U W key to move ID X 85 Y 236 H 2 A 0 the cursor to right Ex Height 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 6 Select angle of barcode by depressing or key ID X 85 Y 236 H 2 A 0 Ex Angle of bar code 0 degree 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 ...

Страница 57: ... B Set up the label size in maintenance mode C Copy the standard format in copy of format in program mode D Change the format in Free Format Program in program mode A LABEL FORMAT Standard format 2 Free format 1 All manuals and user guides at all guides com ...

Страница 58: ...THE FORMAT Change the print data of label format data Refer to 2 8 FREE FORMAT SETING E 1 Select free format No 1 E 2 Set angle of label format 0 degree E 3 Change the print position for ID code at X 0 Y 0 to delete E 4 Change the print position for part no at X 0 Y 0 to delete E 5 Change the print position for lot no at X 0 Y 0 to delete E 6 Change the data for part name L1 D 16 X 0 Y 275 S1 M1 L...

Страница 59: ...from 11 size in Address 34 which is in common with label size of free format Ref to 2 8 a Label Size in Free Format Setting 2 9b Programmable Item Data for Shelf Location Label This chart shows the data type in setting each Item data PRINTING FACTORS DATA BASE ID CODE TYPE 1 PARTS NO TYPE 2 PARTS NAME TYPE 2 UNIT WEIGHT TYPE 1 LOCATION NO TYPE 1 THRESHOLD TYPE 1 DATE TYPE 1 TIME TYPE 1 BAR CODE ID...

Страница 60: ...ation label is the same as in free format Refer to 2 8f Character size and magnifications in Free Format Setting 2 9g Programming Screen The programming screens for item data are the same as free format Refer to 2 8g Programming screen in Free Format Program 2 9h Function Key The function keys in programming Shelf Location Label are the same as free format Refer to 2 8 Function Key in Free Format ...

Страница 61: ...ct item data by depressing UNIT WEIGHT or TARE key S L PART NAME Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Set Print Items in the procedure in 2 8I Item setting in Free Format Setting 8 Store the data by pressing ENTER key PRG S LOCATION LABEL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note While programming print data the programmed data may be printed in test label With uins this function you can che...

Страница 62: ...n Free Format Program in program mode A SAMPLE LABEL FORMAT B THE LIST OF LABEL FORMAT TO THE SAMPLE LABEL DATA Digits no X position Y position Ssiz e Msize ID CODE 200 545 S2 M2 P NO L1 32 50 650 S1 M1 P NAME L1 32 100 650 S1 M1 LOCATION NO 380 686 S1 M2 BARCODE ID 280 750 H0 A3 TEXT 4 100 750 S1 M2 TEXT 5 50 750 S1 M1 TEXT 6 200 50 S1 M2 Print angle 270 All manuals and user guides at all guides ...

Страница 63: ...4 Set the data for part name L1 D 32 X 100 Y 650 S1 M1 E 5 Set the data for location no X 380 Y 686 S1 M2 E 6 Set the data for barocode of ID code X 280 Y 750 H0 A3 E 7 Set the data for text 4 X 100 Y 750 S1 M2 E 8 Set the data for text 5 X 50 Y 750 S1 M1 E 9 Set the data for text 6 X 200 Y 50 S1 M1 NOTE After changing each print data we recommend you would check with the test print if the print p...

Страница 64: ...er to 2 2 ID code setting The location of parts can be discriminated by 8 digits The first 2 digits are to be fiexed for scale no The first 2 digits are printed on reports as scale no The remaining 6 digits identify the following 0 1 0 2 0 2 5 E SCALE ROW RACK SHELF BIN 1 2 3 4 A B C D E F Note 1 The same shelf location number cannot be assigned in any other part All manuals and user guides at all...

Страница 65: ...ble character and the available characters Programmable characters available characters for a set 0 0 1 0 1 9 0 1 2 3 4 5 6 7 8 9 A 0 1 2 3 4 5 6 7 8 9 A Z 0 1 2 3 4 5 6 7 8 9 A Z 2 10c Programming Operation 1 Enter Program Mode and select SHELF LOCATION LIMIT PRG S LOCATION LABEL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key LIMIT 00 00 00 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8...

Страница 66: ...de and select Address Contents PRG ADDRESS CONTENTS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key A C FILE NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 3 Select file no by pressing or key Ex File No 3 A C FILE NO 3 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 4 Press ENTER key F3 ADDRESS NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 5 Select ...

Страница 67: ...S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 10 Select address no by pressing or key Ex Address no 2 F3 ADDRESS NO 2 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor Program address data with the same procedure as above 11 Enter the data into memory file F3 ADDRESS NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 12 Press ENTER key A C FILE NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 ...

Страница 68: ...TER key F3 ADDRESS NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Blinking Cursor 5 Select address no by pressing or key Ex Address no 1 F3 ADDRESS NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Enter the data 23 T E R A O K A S E I K O C O Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depres CLEAR key to enter the deletion screen DEL T E R A O K A S E I K O C O Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 8...

Страница 69: ...68 3 MAINTENANCE MODE All manuals and user guides at all guides com ...

Страница 70: ...EMORY DELETE 92 3 3a Deleting Memory File 93 3 4 PRINT ADJUSTMENT 94 3 4a Feed Value Program 94 3 4b Detection Level Programming 95 3 4c Print Contrast Program 96 3 5 AUTO JOB OPERATION PROGRAM 99 3 5a Programmable task 99 3 5b Default Setting 99 3 5c Programming Screen for Task Order 100 3 5d Programming Task Order 100 3 6 FL 1 COMMUNICATION 102 3 6a Data Back up 102 All manuals and user guides a...

Страница 71: ...COMMUNICATION 103 3 7a Data Transmission Procedure Access Side 103 3 7b Data Transmission Procedure Awaiting Side 106 3 8 SPEC LIST PRINTING 107 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 72: ...ODE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Maintenance mode by depressing ENTER key MEN METHOD PROGRAM Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select each file in Maintenance Mode by depressing TARE or UNIT WEIGHT key MEN MEMORY DELETE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter the displayed mode by depressing ENTER key DEL ALL MEMORY Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Ea...

Страница 73: ...RE and UNIT WEIGHT key Select the headings in loop routines Move the cursor to left right when there are purl cursors in a display PLUS and MINUS key To select the data when cursor of triangle indicator is blinking CURSORS The cursors appear when setting data The cursor shows not only the maximum number of digits but also the characteristic of the entering data 1 Light cursor The numeric data shou...

Страница 74: ... go forth Depress key to go back CLAUSE OF SPEC SELECTION ITEM Make selection with or keys Note TARE or UNITE WEIGHT keys work for moving cursor Note ENTER key works for entering the data into the memory 3 2b Programming SPECs 1 Enter Maintenance mode by depressing ENTER key MEN METHOD PROGRAM Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Method Program by depressing ENTER key MTP DISPLAY Z S N ...

Страница 75: ... 3 I R M I O 1 2 3 4 5 6 7 8 7 Change the SPEC by depressing key 06 ITM THRESHOLD N Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 8 Enter the data to Memory by pressing ENTER key 07 ITM OUT N Ready for entering the next address Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note After you change all the SPECs depress AUTO MANUAL key to escape the programming screen of SPECs Note OUTSIDE APPARATUS SPEC is divid...

Страница 76: ...EC 02 Print Parts Name on Item Report This SPEC actives only when SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 03 Print Unit Weight on Item Report This SPEC actives only when SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 04 Print Shelf Location no on Item Report This SPEC actives only when SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 05 Print In...

Страница 77: ...n SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 10 Print Set Point on Item Report This SPEC actives only when SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 11 Print Selected scale no on Item Report This SPEC actives only when SPEC 00 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 12 Print Auto Job No for shipping operation on Item Report This SPEC actives ...

Страница 78: ... 15 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 18 Print Unit Weight on Today s Movement Report This SPEC actives only when SPEC 15 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 19 Print Shelf Location no on Today s Movement Report This SPEC actives only when SPEC 15 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 20 Print Inventory on Today s Movement Report This SPEC a...

Страница 79: ... REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 26 Print Selected scale no on Today s Movement Report This SPEC actives only when SPEC 15 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 27 Print Auto Job No for shipping operation on Today s Movement Report This SPEC actives only when SPEC 15 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 28 Print Auto Job No for receiving opera...

Страница 80: ...PORT SPEC is set to SELECT Y Allow N Inhibit SPEC 34 Print Shelf Location no on Threshold Report This SPEC actives only when SPEC 30 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 35 Print Inventory on Threshold Report This SPEC actives only when SPEC 30 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 36 Print Threshold on Threshold Report This SPEC actives only when SPEC 30 of REPO...

Страница 81: ...n Threshold Report This SPEC actives only when SPEC 30 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 42 Print Auto Job No for shipping operation on Threshold Report This SPEC actives only when SPEC 30 of REPORT SPEC is set to SELECT Y Allow N Inhibit SPEC 43 Print Auto Job No for receiving operation on Threshold Report This SPEC actives only when SPEC 30 of REPORT SPEC is set to SELECT Y ...

Страница 82: ...an readable number under bar code ID code Y Allow N Inhibit SPEC 04 Print Bar code of Parts No Y Allow N Inhibit SPEC 05 The first digit of Parts No data on bar code 0L 16L 0L 16L SPEC 06 The last digit of Parts No data on bar code 0L 16L 0L 16L SPEC 07 Print Human readable number under bar code Parts No Y Allow N Inhibit SPEC 08 Print bar code of lot no Y Allow N Inhibit All manuals and user guid...

Страница 83: ... Allow N Inhibit SPEC 12 Print bar code of quantity Y Allow N Inhibit SPEC 13 Print Human Readable number under bar code Q ty Y Allow N Inhibit SPEC 14 Print bar code of unit weight Y Allow N Inhibit SPEC 15 Print Human Readable number under bar code Unit Weight ALL All Items SELECT Selected Items SPEC 16 Print bar code of tare Y Allow N Inhibit All manuals and user guides at all guides com ...

Страница 84: ... Y Allow N Inhibit SPEC 20 Print bar code of net weight Y Allow N Inhibit SPEC 21 Print Human Readable number under bar code net weight Y Allow N Inhibit SPEC 22 Label Print ALL All operation OUT Shipping Operation IN Receiving Operation N A Non add Operation I O Receiving and Shipping Operations NON No Printing SPEC 23 Print Title of task Y Allow N Inhibit All manuals and user guides at all guide...

Страница 85: ...Allow N Inhibit SPEC 27 Width of receipt paper 66MM 66mm 40MM 40mm SPEC 28 Type of sum total receipt issued in multiple transaction LONG Long SHORT Short SPEC 29 Print the current time Y Allow N Inhibit SPEC 30 Print the current date Y Allow N Inhibit SPEC 31 Free Format Y Allow N Inhibit SPEC 32 Free Format No All manuals and user guides at all guides com ...

Страница 86: ...SPEC 35 Type of bar code CODE39 Code 39 UPC A UPC A SPEC 36 Type of UPC bar code 13 13 Digits 8 8 Digits SPEC 37 Number system character NS of UPC bar code 0 9 0 9 SPEC 38 Print header code on bar code Code 39 only Y Allow N Inhibit SPEC 39 Feed label after printing the last label in continuous printing Y Allow N Inhibit All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 87: ...r scanner connection TTL TTL Serial 232C RS 232C SPEC 03 Bit Length Scanner 7 7 bit 8 8 bit SPEC 04 Parity bit Scanner NONE None ODD Odd EVEN Even SPEC 05 Bit Length Scanner 1200 2400 4800 9600 19200 SPEC 06 Stop Bit Scanner 1 1 bit 2 2 bit SPEC 07 Refer to scanning data as ID code Y Allow N Inhibit SPEC 08 Ignore spaces in bar code SPACE DATA All manuals and user guides at all guides com ...

Страница 88: ... COUNT Internal Count WEIGHT Weight data SPEC 01 Bit Length F B 7 7 bit 8 8 bit SPEC 02 Parity bit F B NONE None ODD Odd NONE None SPEC 03 Communication Speed F B 2400 2400 BPS 4800 4800 BPS 9600 SPEC 04 STOP BIT F B 1 1 2 2 All manuals and user guides at all guides com ...

Страница 89: ... BPS 2400 2400 BPS 4800 4800 BPS 9600 9600 BPS 19200 19200 BPS SPEC 03 STOP BIT RS 232 1 1 2 2 SPEC 04 Timing of RS 232C Output NOT No Output CA by calculation by ENTER key C by calculation and ENTER key SPEC 05 RS 232C INPUT Y Allow N Inhibit SPEC 06 RS 232C input field delimiter CR Carriage Feed LF Line Feed All manuals and user guides at all guides com ...

Страница 90: ...ONNECT Connected SPEC 01 Dial type of telephone PULSE Pulse dial TONE Tone dial OTHER SPEC SPEC 00 Read Header data on bar code Y Allow N Inhibit SPEC 01 Connection of IBM Keyboard NOT Not connected CONNECT Connected All manuals and user guides at all guides com ...

Страница 91: ...uting Unit Weight SPEC 02 Keep Lot No Y Allow N Inhibit SPEC 03 Renew the inventory data when counting item in Non add Operation Y Allow N Inhibit SPEC 04 Auto Job No for a whole Items shipping PAT1 5 Pattern 1 Pattern 5 SPEC 05 Auto Job No for a whole Items receiving PAT1 5 Pattern 1 Pattern 5 SPEC 06 Auto Job No for a whole Items Non add PAT1 5 Pattern 1 Pattern 5 SPEC 07 Prohibit to use Power S...

Страница 92: ... 11 Warn when operation will result in an inventory less than threshold level Y Allow N Inhibit SPEC 12 Date Format D M Y DD MM YY M D Y MM DD YY Y M D YY MM DD SPEC 13 Calling ID code in Auto Job Operation Y Allow N Inhibit SPEC 14 Prohibit to count Non ID code Item Y Allow N Inhibit SPEC 15 Memory Size 385 385 Items 3080 3 080 Items All manuals and user guides at all guides com ...

Страница 93: ... Threshold data of all items DAILY OUT COUNT Today s shipping record of all items DAILY IN COUNT Today s receiving record of all items TARE VALUE Tare values of all items SET POINT VALUE Set point values of all items SELECTED SCALE NO Selected scale no of all items AUTO JOB NO FOR SHIPPING OPERATION Auto job no for shipping operation of all items AUTO JOB NO FOR RECEIVING OPERATION Auto job no for...

Страница 94: ...W keys DEL ITEM MEMORY Ex ITEM MEMORY FILE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key ITM PART NO Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Select Item Data to delete by depressing TARE or U W keys ITM INVENTORY Ex INVENTORY Data Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Press ENTER key INVENTRY DEL Y N Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Depress Y key to delete the data N k...

Страница 95: ...he label present to the proper value for printing F E E D V A L U E 0 Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Key Functions key is used for the increment of the feed value Max 127 key is used for the decrement of the feed value Max 127 feed key is used for feeding label to check the proper feed value Programming Feed Value 1 Select Print Adjustment Mode in Maintenance Mode by depressing TARE MEN P...

Страница 96: ...tically on feeding label out If the sensor cannot detect the gap between labels use this option to adjust the label present to the proper value for printing LEVEL 2 8 0 Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Detection level Key Functions key is used for the increment of detection level Max 127 key is used for the decrement of detection level Max 127 feed key is used for feeding label to check the...

Страница 97: ...ustment setting Mode by pressing AUTO MANUAL key ADJ FEED VALUE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 4c Print Contrast Program This option is to control the heart of the thermal head when printing The higher the number the hotter the head and the darker the print will be This is set to 0 at factory default Since the thermal head may be damaged when setting higher value we recommend to set the...

Страница 98: ...FEED VALUE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select PRINT CONTRAST Setting Mode by pressing TARE or U W keys ADJ PRINT CONTRAST Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key CONTRAST 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Adjust the print contrast with and key Ex 1 CONTRAST 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Exit the Print Adjustment setting Mode by pressing AUT...

Страница 99: ...98 All manuals and user guides at all guides com ...

Страница 100: ...g receiving non add operations of each ID code 3 5a Programmable task Ref Tasks A Lot No Entry by pressing Numeric keys or scanning B Parts No Entry by pressing Alpha numeric keys or scanning C Tare Entry by pressing Numeric keys scanning or one touch tare D Unit Weight Entry by sampling E Unit Weight Entry by Pressing Numeric keys F Counting task G Quantity Entry by pressing Numeric keys H Label ...

Страница 101: ...or moving cursor 3 5d Programming Task Order 1 Select Auto Job Setting Mode in Maintenance Mode by depressing TARE MEN AUTO JOB SET or U W keys Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key AUTO JOB SET NO 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select Pattern No by pressing or keys AUTO JOB SET NO 3 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key 3 OV CEFHJ Z S N K 1...

Страница 102: ...hange Task order by depressing D key Ex Pattern 3 CDFHJ 3 OV CDFHJ Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Store the data by pressing ENTER key AUTO JOB SET NO 3 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 All manuals and user guides at all guides com ...

Страница 103: ... Maintenance Mode by depressing TARE MEN FL 1 MEMORY or U W keys Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key FL1 METHOD PROGRAM Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select Data File to back up by pressing TARE or U W keys FL1 PRINT FORMAT Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key PRINT FORMAT READ Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Select Load Save Ver...

Страница 104: ...JOB OPERATION PRINT FORMAT FILE All ITEM DATA 3 7a Data Transmission Procedure Access Side 1 Select Data Transmission Mode in Maintenance Mode by depressing TARE MEN MODEM COMM or U W keys Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key MDM MODEM MANUAL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Depress ENTER key MAN ENTER TELEPHONE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter teleph...

Страница 105: ...with Y yes or N No key RCV PRINT FORMAT Y N Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 9 Select if transmitting Print Format data with Y yes or N No key RCV AUTO JOB Y N Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 10 Select if transmitting Auto Job Data with Y yes or N No key RCV ALL ITEM Y N Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 11 Select if transmitting Item Data with Y yes or N No key RCV START Y N ...

Страница 106: ...105 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 NOTE The data on addressee side is to be overwritten on the existing data All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 107: ...keys Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Depress ENTER key MDM MODEM MANUAL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select awaiting AUTO side by pressing TARE or U W keys MDM MODEM AUTO Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key WAITE Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 All manuals and user guides at all guides com ...

Страница 108: ... 2 Enter Maintenance mode by depressing ENTER key MEN METHOD PROGRAM Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select SPEC List Print Mode by depressing TARE or U W keys MEN SPEC LIST Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Depress ENTER key to print SPEC LIST PRINTING Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Set the receipt in the label cassette All manuals and user guides at all guides com...

Страница 109: ...4 CHECK MODE 106 All manuals and user guides at all guides com ...

Страница 110: ...tion In Check Mode 109 4 2 MEMORY CONTENTS 110 4 2a All Item Report 110 4 2b One Item Report 111 4 2c Group Report 112 4 3 INVENTORY REPORT 113 4 3a In Out Reprt 113 4 3b Threshold Reprt 114 4 4 SHELF LOCATION LABEL PRINT 115 107 All manuals and user guides at all guides com ...

Страница 111: ...key ITM 180 REST 205 The number of ID code exsiting and remaining are displayed Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Dpress ENTER key CHK MEMORY CONTENTS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Select each file in Check Mode by depressing TARE or UNIT WEIGHT key CHK INVENTRY Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Enter the displayed mode by depressing ENTER key INV IN OUT Z S N K 1 2 3 I...

Страница 112: ...g programmed data AUTO MANUAL key To return to the previous screen in programming ENTER key To enter the next screen in each file To print report or label CLEAR key To clear mis set data TARE and UNIT WEIGHT key To select the headings in loop routines 109 All manuals and user guides at all guides com ...

Страница 113: ...em 4 2a All Item Report 1 Select item Report Mode in Check Mode by depressing TARE or U W key CHK MEMORY CONTENTS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Report Mode MEM ALL ITEMS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Print All Item Report by depressing ENTER key ITEM PRINTING XXX Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Set Receipt roll when printing item report Note Press FEED ke...

Страница 114: ...1 2 3 4 5 6 7 8 3 Select one item report by depressing TARE or U W key MEM 1 ITEM ENTER ID Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter ID code Ex ABC100 1IT ABC100 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Print 1 Item Report by depressing ENTER key MEM 1 ITEM ENTER ID Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Set Receipt roll when printing item report 111 All manuals and user guides at all...

Страница 115: ...TS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Report Mode MEM ALL ITEMS Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Select Group item report by depressing TARE or U W key MEM ACCORDING GROUP Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter Group code Ex ABC GRP ABC Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Print Group Item Report by depressing ENTER key MEM ACCORDING GROUP Z S N K 1 2 3 I R M I ...

Страница 116: ...ss stock against threshold can be entered and all items over below the item are printed By checking stock level operator can prevemt item from being over stock or less stock 4 3a In Out Reprt 1 Select Inventory Report in Check Mode by depressing TARE or U W key CHK INVENTORY Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Invenotry Report Mode INV IN OUT Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 P...

Страница 117: ...ld Report by depressing TARE or U W key INV THRESHOLD Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Enter the percentage of excess or lack range by pressing numeric key THRESHOLD 30 Ex 30 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Select excess or lack range of stock by pressing excess or lack keys INV THRESHOLD Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 NOTE key is used to stop printing the report 114 Al...

Страница 118: ... 1 2 3 4 5 6 7 8 2 Enter Shelf Location Label Print Mode by pressing ENTER key S L LABEL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Enter ID code to print LAB ABC 100 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Press ENTER key twice ID ABC 100 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Escape by press AUTO MANUAL key S L LABEL Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 115 All manuals and user guides at ...

Страница 119: ...5 OPERATION MODE 116 All manuals and user guides at all guides com ...

Страница 120: ...try 121 4 3 b Tare Entry by Numeric keys 121 4 4 Part No Entry 122 4 5 Lot No Entry 122 4 6 Sequence No Entry 123 4 7 ID code Entry 123 4 8 Parts Counting Operation 124 4 8a Single Transaction 124 4 8b Maltipule Transaction 125 4 9 Continuous Label Print 126 4 10 Adress Data Entry 127 4 11 Gross Weight Display 127 4 12 Auto Job Operation Mode 128 117 All manuals and user guides at all guides com ...

Страница 121: ...Shift up for symbol characters entry z CODE Key Recall Item Code z A to Z Keys Enter Alphabetical data z ENTER Key Print single or total accumulation z CLEAR Key Clear keyed in data z DECIMAL Key Enter the decimal point DC 150 Indicator Lamps n ZERO Lamp Zero point is set t MEMORY Lamp An accumulated total is in memory o STABLE Lamp Weight is stable u IN Lamp Quantities being added to inventory p ...

Страница 122: ...9970 84 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Press PIECES key 0 0835 0 9917 84 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 If using a sample of 10 pcs press PIECES key without entering a number of sample Note 2 To have accurate unit weight calculation the sample weight must be more than the insufficient range of the scale Insufficient range 0 0 0 7 of scale capacity If sample weight is les...

Страница 123: ...lue with numeric keys Ex 3 756kg 1000pcs 5 3 756 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press UNIT WEIGHT key 1 0 0000 3 7560 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 The unit weight value should be Unit Weight 1 000 Note 2 To clear unit weight press 0 and UNIT WEIGHT key 120 All manuals and user guides at all guides com ...

Страница 124: ... 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note To clear tare weight enter 0 and TARE key 4 3 b Tare Entry by Numeric keys 1 Stand by Status 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Tare Weight Value with numeric keys Ex 0 0275 6 0 0275 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press TARE key 0 0275 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note To clear tare weight enter 0 and TARE key ...

Страница 125: ...6 7 8 Note The parts no may be cleared automaticaly by entering antother item data 4 5 Lot No Entry 1 Stand by Status 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter Lot No Ex CWNICO124 13 C W N I C 0 1 2 4 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press LOT NO key 0 0000 0 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Lot no may be cleared automaticaly by entering another Item Code ...

Страница 126: ... 0 0000 0 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note Sequence no increses automaticaly by issuing a label Note When seuqence no is set to 0 it is not printed and incresed 4 7 ID code Entry 1 Stand by Status 0 0000 0 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter ID code Ex ABC 100 125 11 ABC 100 125 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press CODE key 0 0000 0 1230 0 Z S N K 1 2 3 I R...

Страница 127: ...5 0 1233 2590 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Print labels by pressing ENTER key 0 3195 0 1233 2590 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 Quantities received IN or shipped OUT of inventory are receoored for each ID code So when counting item in ID code file change the task on procerure 2 Note 2 When both of IN and OUT lamps are off the quantities do not reflect Inventory Note 3 ...

Страница 128: ...O 1 2 3 4 5 6 7 8 6 Delete the quantity in Memory by pressing key 2 0 0240 0 1233 194 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 7 Print total accumulation label and clear memory 3 0 0240 0 1233 194 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 Quantities received IN or shipped OUT of inventory are receoored for each ID code So when counting item in ID code file change the task on procerure 2 Note 2...

Страница 129: ... N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Press CLEAR key to escape 0 0000 0 1233 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Place parts on platter 0 3195 0 1233 2590 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Print labels by pressing ENTER key 1 0 3195 0 1233 2590 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 Note 1 The number of labels entered in procedure 2 are printed The quantities are receoored for e...

Страница 130: ...splay 1 After entering unit weight and tare weight by any method 0 0000 0 1233 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Place parts on platter Ex 0 3195kg 0 3315 0 1233 2690 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Press SHIFT DOWN then M NET GROSS key within 3 seconds to enter Gross Weight 3 650 Mode 1 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Print labels by pressing ENTER key 2 3 650 Z S N ...

Страница 131: ...2 3 I R M I O 1 2 3 4 5 6 7 8 2 Enter ID code Ex ABC 100 125 ABC 100 125 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 3 Press CODE key 0 0000 0 1230 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 4 Change task IN OUT NON ADD by pressing SHIFT DOWN then DECIMAL 0 0000 0 1230 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 5 Press AUTO Manual key 1 0 0000 0 1230 0 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 6 Enter Lot...

Страница 132: ...Press ENTER key 0 0240 0 1230 193 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 10 Press ENTER key to print 0 0240 0 1230 193 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 11 Press ENTER key 0 0240 0 1230 193 Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8 129 All manuals and user guides at all guides com ...

Страница 133: ...Appendix I All manuals and user guides at all guides com ...

Страница 134: ... 8 QUANTITY 230 8 S5 M1 9 QTY UNIT 424 8 S1 M0 10 DATE 0 8 S1 M1 11 TIME 120 8 S1 M1 12 TASK CONTENTS 0 70 D2 M1 13 SUM TOTAL 146 40 S2 M1 14 SUM COUNT 90 40 S2 M1 15 TITLE 1 227 8 S2 M1 15 TITLE 2 0 76 S2 M1 16 TITLE 3 242 76 S2 M1 17 GROSS WT G 316 8 S2 M1 18 UNIT W T G 424 8 S1 M0 19 NET W T G 54 76 S2 M1 20 NET UNIT G 178 76 S1 M0 21 TARE W T G 316 76 S2 M1 22 TARE UNIT G 424 76 S1 M0 II All m...

Страница 135: ...9 MARK 200 8 S5 M1 10 QUANTITY 230 8 S5 M1 11 QTY UNIT 424 8 S1 M0 12 DATE 0 8 S1 M1 13 TIME 120 8 S1 M1 14 TASK CONTENTS 0 70 D2 M1 15 SUM TOTAL 146 40 S0 M1 16 SUM COUNT 90 40 S2 M1 17 TITLE 1 227 8 S2 M1 18 TITLE 2 0 76 S2 M1 19 TITLE 3 242 76 S2 M1 20 GROSS WT G 316 8 S2 M1 21 UNIT W T G 424 8 S1 M0 22 NET W T G 54 76 S2 M1 23 NET UNIT G 178 76 S1 M0 24 TARE W T G 316 76 S2 M1 25 TARE UNIT G 4...

Страница 136: ...8 S5 M1 11 QUANTITY 230 8 S5 M1 12 QTY UNIT 424 8 S1 M0 13 DATE 0 8 S1 M1 14 TIME 120 8 S1 M1 15 TASK CONTENTS 0 70 S2 M1 16 SUM TOTAL 146 40 S0 M1 17 SUM COUNT 90 40 S2 M1 18 BARCODE ID 12 354 H0 A0 19 TITLE 1 227 8 S2 M1 20 TITLE 2 0 76 S2 M1 21 TITLE 3 242 76 S2 M1 22 GROSS WT G 316 8 S2 M1 23 UNIT W T G 424 8 S1 M0 24 NET W T G 54 76 S2 M1 25 NET UNIT G 178 76 S1 M0 26 TARE W T G 316 76 S2 M1 ...

Страница 137: ...8 S5 M1 10 QUANTITY 8 246 S5 M1 11 QTY UNIT 8 44 S1 M0 12 DATE 8 514 S1 M1 13 TIME 8 372 S1 M1 14 TASK CONTENTS 70 514 S2 M1 15 SUM TOTAL 40 334 S0 M1 16 SUM COUNT 40 390 S2 M1 17 BARCODE ID 370 680 H0 A3 18 TITLE 1 8 263 S2 M1 19 TITLE 2 76 514 S2 M1 20 TITLE 3 76 263 S2 M1 21 GROSS WT G 8 174 S2 M1 22 UNIT W T G 8 23 S1 M0 23 NET W T G 76 474 S3 M1 24 NET UNIT G 76 300 S1 M0 25 TARE W T G 76 174...

Страница 138: ...11 QUANTITY 230 8 S5 M1 12 QTY UNIT 424 8 S1 M0 13 DATE 0 8 S1 M1 14 TIME 120 8 S1 M1 15 TASK CONTENTS 0 70 S2 M1 16 SUM TOTAL 146 40 S0 M1 17 SUM COUNT 90 40 S2 M1 18 BARCODE ID 14 448 H0 A0 19 TITLE 1 222 8 S2 M1 20 TITLE 2 0 76 S2 M1 21 TITLE 3 222 76 S2 M1 22 TITLE 4 20 374 S2 M1 23 TITLE 5 20 294 S2 M1 24 TITLE 6 20 214 S2 M1 25 TITLE 7 20 170 S2 M1 26 GROSS WT G 316 8 S2 M1 27 UNIT W T G 424...

Страница 139: ... BARCODE ID 370 680 H0 A3 25 BARCODE QTY 227 278 H0 A3 26 BARCODE TARE 25 278 H0 A3 27 BARCODE UNIT 125 278 H0 A3 28 TITLE 1 187 680 S2 M1 29 TITLE 2 152 680 S2 M1 30 TITLE 3 117 680 S2 M1 31 TITLE 5 30 680 S0 M1 32 TITLE 6 323 680 S3 M1 33 TITLE 7 3 680 S0 M1 34 TITLE 8 256 680 S3 M1 35 TITLE 9 220 680 S2 M1 36 TITLE 10 85 680 S0 M1 37 TITLE 11 150 370 S2 M1 38 TITLE 12 252 370 S2 M1 39 TITLE 13 ...

Страница 140: ...LE 2 261 433 S2 M1 10 TITLE 3 261 220 S2 M1 11 TITLE 6 323 680 S3 M1 12 TITLE 8 256 680 S3 M1 13 TITLE 12 252 370 S2 M1 22 GROSS WT G 261 584 S3 M1 23 UNIT W T G 261 470 S1 M0 33 NET W T G 261 383 S3 M1 34 NET UNIT G 261 250 S1 M0 35 TARE W T G 261 141 S3 M1 36 TARE UNIT G 261 29 S1 M0 37 ADDRESS 1 180 610 S3 M1 38 ADDRESS 2 140 610 S3 M1 39 ADDRESS 3 100 610 S3 M1 40 ADDRESS 4 60 610 S3 M1 41 ADD...

Страница 141: ...RD 2 x 4 x S 1 6 x 10 dots STANDARD 2 x 4 x S 2 7 x 12 dots STANDARD 2 x 4 x S 3 7 x 16 dots STANDARD 2 x 4 x S 4 9 x 22 dots STANDARD 2 x 4 x S 5 14 x 22 dots STANDARD 2 x 4 x IX All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 142: ...APPENDIX III REPORT SAMPLE ALL ITEM ONE ITEM GROUP ITEM X All manuals and user guides at all guides com ...

Страница 143: ...APPENDIX IV INVENTORY REPORTS TODAY S MOVEMENT REPORT THRESHOLD REPORT XI All manuals and user guides at all guides com ...

Отзывы: