background image

                       

 

List with direct access numbers

 

D3936-GB Rev C                                                     EZ3400VL User' s manual                                                                     

24

COMMONLY USED DIRECT ACCESS NUMBERS 

 

 

Ingredient Name Table 

The Ingredient Name Table contains 99 entries made up of ingredients and pens that are used 
when programming a recipe. 
 

Number Of Ingredients 

Defines how many ingredients are in the Ingredient Name Table.  The default is 30 ingredients and 
69 pens. 
 

 

1.  Enter 

473

 press          . 

2.  Enter the number of ingredients 

3.  Press           to save. 

 

 
 

Pre-alarm 

 

 

[

P-ALM

Select weight or percentage method. Enter value to activate early warning sign when indicator 
reaching preset value. 
 

 

 

1.  Enter 

401

 press          . 

2.  Press           to select 

WEIGHT

 or 

PERCNT

3.  Press           to save. 

4.  Enter the pre-alarm value in weight or 

percent. 

5.  Press           to save. 

 

 
 

Auto Advance 

When the auto advance feature is activated the indicator automatically advances to the next 
ingredient once the tolerance and delay time requirements are met. 
 

Tolerance 

[

TOLER

]  

Tolerance is a specific percentage or weight of the desired amount. When reaching the desired 
amount minus the “

Tolerance”

, the weighing indicator will accept the loaded amount and 

automatically advance to the next ingredient, depending on the set delay time. 
 

401

473

1/2 

2/4 

3/5 

Содержание EZ3400VL

Страница 1: ...EZ3400VL User s manual Ft Atkinson Wisconsin USA Panningen the Netherlands www digi star com D3936 GB REV C June 24 2013 HELLO...

Страница 2: ......

Страница 3: ...ng ingredient names 15 Running a recipe according to amount per animal 16 ADVANCED FUNCTIONS 18 Holding the displayed amount 18 Backlight intensity 18 Preset presetting 18 Display in gross weighing mo...

Страница 4: ...his manual in any form whatsoever without Digi Star s express written permission is forbidden The contents of this manual are subject to change without notice All efforts have been made to assure the...

Страница 5: ...TS 10 5 to 16 0 V D C 160 mA nominal with four 350 L C SET UP AND CALIBRATION Via front panel GROSS RANGE 999 999 max display LOW BATTERY WARNING Enabled at 10 5V nominal POUND KILOGRAM Selectable DIS...

Страница 6: ...Digi Star cannot be held responsible for deviations and problems arising from technical problems to the system Cleaning Do not use running water high pressure cleaners hoses to clean the indicator Ch...

Страница 7: ...ill run self test 6 turns indicator off 7 Display Window Displays current actions 8 temporary zero Net mode 9 records to memory or prints displayed weight 10 toggles between Net and Gross weights 11 s...

Страница 8: ...dd space in command 20 Serial port printer port communication with inputs and outputs of the computer and other digital devices optional 21 Port for remote display to connect the remote display option...

Страница 9: ...ser s manual 9 OPERATION Switching on the weighing indicator 1 Press Switching off the weighing indicator 2 Press Zero balancing the weighing indicator 1 Press and hold for 3 seconds to zero balance t...

Страница 10: ...xample with a total weight of 1000Kg this will be 550 kg silage and 450 kg corn Attention the total must be 100 3 Amount per ingredient Enter the required total amount per ingredient For example 2500...

Страница 11: ...pe 1 Press and hold for 3 seconds 2 PRoGRm will briefly display followed by a The first programmed recipe or b rec __ This indicates that the memory is empty 3 Enter a new recipe number 4 Press to sto...

Страница 12: ...or pen name by pressing the key See page 10 changing ingredient or pen name steps 5 through 8 for the procedure Please note that this will also affect other recipes where this ingredient pen is used...

Страница 13: ...ready repeatedly press until you see done 7 Press one more time to store the changes and leave the recipe Insert ingredient or pen in a recipe 1 Enter the recipe programming mode See Enter programming...

Страница 14: ...ress one more time to store the changes and leave the recipe Note If you want to insert an ingredient or pen at the end of the recipe go through the recipe until you see done and then press 1 Enter th...

Страница 15: ...s to display first recipe Repeatedly press or to go to the recipe you want to print 2 Press to print this recipe 3 Press twice to print all the recipes saved in the memory 4 Press to return to normal...

Страница 16: ...ingredient the total amount TOTamt will be displayed 6 After RESIZING all pens the indicator displays the first ingredient and amount to load While loading the ingredient the weight on the indicator c...

Страница 17: ...Operation D3936 GB Rev C EZ3400VL User s manual 17 11 After the last pen has been fed the indicator displays done TOTAL comple...

Страница 18: ...educe the backlight intensity by 60 Press again to return to the full intensity Preset presetting If you want to manually load or unload a specific amount you can enter a preset weight in the weighing...

Страница 19: ...e gross weight While loading or unloading a preset amount the weighing indicator starts counting down The word PRESET and the required amount will be displayed alternately until 5 of the required amou...

Страница 20: ...tare weight This function is used to trace the net content of for example a container that has already been filled If you know the empty weight of the container this tare weight can be entered in the...

Страница 21: ...cal dots which briefly light up every second After the mixing clock has started the time on the display will count down to 00 00 00 1 Press 2 Enter the mixing time HH MM SS 3 Press to confirm the ente...

Страница 22: ...on of select key PRGREC PRGREC PRGREC PRGREC Create or edit recipes 2 When the required option is displayed press to activate this option Calling up accumulative ingredient amounts Display the total a...

Страница 23: ...ACCUM displayed 2 Press Press to display pens Press to display ingredients 3 Use or to go to the required ingredient pen 4 Press to print accumulation value for the ingredient pen 5 Press to exit Pri...

Страница 24: ...ethod Enter value to activate early warning sign when indicator reaching preset value 1 Enter 401 press 2 Press to select WEIGHT or PERCNT 3 Press to save 4 Enter the pre alarm value in weight or perc...

Страница 25: ...ght Delay time DELAY Enter the time that the weighing indicator should wait before advancing to the next ingredient 1 Enter 443 press 2 Enter delay time in seconds 3 Press to save NOTE Set to 0 preven...

Страница 26: ...0VL User s manual 26 Drive ratio DRATIO Drive ratio is the number of revolutions of the power take off of the feed mixer divided by the number of revolutions of the mixer auger 1 Enter 422 and press t...

Страница 27: ...ss to enter the selected menu 5 Press to scroll through the options 6 Press to change the options 7 Press to save the changes Changing setup and calibration numbers SETUP CAL 1 Enter 871 2 Press 3 Wei...

Страница 28: ...lines or reservoirs Check all J Box and load cell cables for loose contacts cuts or pinched flat spots NO YES Are all values positive negative values indicate that the load cell concerned is mounted...

Страница 29: ...ad cell connected Zero balance the weighing indicator and stand or hang with your weight over the connected load cell Note the weight increase A weighing indicator with only one connected load cell wi...

Страница 30: ...ZP C 840459 SUPPORT HAT BRACKET D 405069 U BOLT 1 4 20 X 3 25 ZP E 405084 NUT 1 4 20 TOP LOCKING FLANGE F 403770 BRACKET WING MOUNT G 405124 PACK WEDGE MOUNT BRACKET WITH U BOLTS FLANGE NUTS H 405244...

Страница 31: ...ections Power supply cable See figure 1 Weighing indicator Digital input output connection optional Remote display connection optional Power supply cable connection J Box connection Pin to 12Vdc power...

Страница 32: ...load cell wires to terminals Tighten nuts Load cell cable J Box cable Wire colours Pin Colour Description 1 Red Power supply 2 Green Signal 3 White Signal 4 Black Power supply 5 Transparent Shield J...

Страница 33: ...D RD2400V CAB CONTROL 2400 2400V 3400 3400V 3600 3600V Conformance to EN 61326 electrical equipment for measurement control and laboratory use see Report Number 307245 EN 55011 for Class B ISM equipme...

Отзывы: