Menus and Calibration
D3714 Rev C
EZ3400 User’s Manual
35
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
DRIVE RATIO
(dratio)
422
0001.00
Enter the number of
input pulses that equal
1 mixer revolution.
GROSS SET
POINT
(SETPNT)
423
5000
Set a gross weight in
long form that will
ac12VDC Alarm
Output on Power cord.
GROSS SET
POINT CHNG
(SETCHG)
424
500
Set required weight
change to turn off
+12VDC Alarm Output.
GROSS SET
POINT DELAY
(SETDEL)
425
0
-10
Set the time delay that
must expire before the
+12VDC Alarm Output
can Turn On/Off.
GROSS SET PNT
OUTPUT
(SETOUT)
426
OVER/
UNDER
Select when the
+12VDC Alarm Output
becomes active.
SET POINT
COUNT
(SET CTR)
427
0
-9
Counts activation of
Code 423
ENTRY METHOD
(E MTHD)
441
1
,2,3
Select batch 1-
amount/animal
2-percent/load
3- amount/load
TOLERANCE
(toler)
442
OFF
,.5,1-5,7,10
Select tolerance weight
percentage to accept
ingredient.
INGR. ADVANCE
DELAY
(delay)
443
MANUAL
, 1-
3,5,7,10,20,30,60
Select seconds to delay
before advancing to
next ingredient.
INGREDIENT
NAMES
(INGRNM)
444
ON/
OFF
If ON displays
ingredient names while
batching
ACCUMULATION
(ACCUM)
445
ON/
OFF
If ON ingredient weights
are accumulated while
batching
INGREDIENT RE-
SIZING
(INGSIZ)
449
1-ING
/OFF
Selects automatic
ingredient re-size mode
PISPLAY SCOOP
%
(SCOOP%)
452
ON
/OFF
If ON displays scoop %
to load
Содержание EZ3400