Step 1:
Make sure the LEIT-2ET controller is out in bright light to harness
light energy used to power the controller. It will take approximately thirty (30)
minutes, or less, in direct sunlight. Do not connect sensor wires at this time.
Wait until controller is charged and ready to be assigned an ID.
Step 2:
Splice the two (2) yellow or yellow and black sensor wires together
using waterproof connectors. This splice will distinguish that the controller is
ready to communicate with a LEIT RC2ET handset.
Step 3:
Connect via RADIO UPLINK screen:
a. On the LEIT RC2ET handset’s MAIN MENU, press and highlight RADIO
UPLINK icon. Press again, CONTROL ID: 00 DEFAULT SETUP with
the first Ø blinking appears. Press again to connect. ARE YOU SURE?
screen appears with RADIO UPLINK icon selected. Press again to
connect, CONNECTED appears momentarily, then, CONTROL ID: 00, NO
DESCRIPTION screen appears. Press again and CONTROL ID: 01, NO
DESCRIPTION appears with Ø blinking. At this point the user can assign a
new Controller ID.
b. To assign a Controller ID, press or and enter a number (1-9) for
the first digit. Press and repeat the steps with the second digit
(we
recommend changing the ID number to a number higher than 01)
.
Next, assign description, name or address (recommended). The default
is NO DESCRIPTION. Press and the first letter of NO DESCRIPTION is
blinking. Press or and enter a letter for the first digit. Press and
repeat the steps for each letter. After completion press to download
the new information with the new ID number and address. Use the new ID
number to connect to this controller and use the address or name to help
identify the controller location.
NOTE:
Setting a new CLIENT ID (A-Z): The default ID is AAA (this is a security feature). If the
controller CLIENT ID is changed from AAA to other letters, the user must update the handset
to the same CLIENT ID after exiting the controller program.
16