background image

16

This screen provides information on the next irrigation
schedule.

Press 

to repeat. Press 

or 

to move to the next feature.

SETTING THE CONTROLLER SYSTEM

This Uplink System menu allows you to set the current controller date and time, activate or de-
activate programs, activate or deactivate budgeting, enter or change master valve or pump settings
and activate monthly irrigation suspension. In this menu you may also set or change controller radio
on/off times, assign an address or description to the controller, activate a sensor, assign a sensor to
one, all valves or a MV/P and change the passwords. After any changes to the system have been
made, a confirmation will appear on the display.

To enter Uplink Setup System press 

.

To enter Uplink System press 

to skip Uplink System and move to the next feature,

press or and 

continue.

If the password appears with the default (AAA), press

to continue. If the password has been changed on

the controller, enter the new controller password to
continue. To enter the password press 

or 

and

underscore the digit to be changed then press 

or

to select the appropriate letter. Repeat the steps for each letter. When finished, press 

or

to underscore OK. Press 

to continue.

Next, the handset will try to establish a link with a LEIT
controller. While the word Connect is blinking, wait for a
conformation. If communication is established, the
Password screen appears. If communication is not
established the No Response-Try Again screen will appear
with Yes highlighted as the default. Press 

again to re-initiate communication with a LEIT

controller that has the same ID.

SETTING THE TIME

In this screen the time is displayed. You may review or
change any of the information if the time displayed is
incorrect. Press 

to continue. To set the time,

underscore the hour digits using 

or 

and press 

or 

to change the setting. Repeat the steps for

changing the minute digit and AM/PM and when finished press 

or 

again to underscore OK.

Press to 

continue.

Password:   AAA

OK

Time:  01:37 PM

OK

Prog1 Strt2 next
Sched 12:50pm

OK

UPLINK

SETUP SYSTEM?

Connect ID:  09
Controller:

OK

15

To remove the letter G from a valve in the group: In the Valve Runtime screen press the 

or 

to

underscore the letter G icon located to left of the hour position. Press

and the letter G will

disappear. Repeat with the other valves as needed. To exit press 

or 

to underscore OK.

Press to 

continue.

The following examples are of groups  (G or 0 can be set for intermediate valves in a group)

Valve #1 set for 0:20 minutes
Valve #2 set for G0:00 or 0:00
Valve #3 set for G0:00 or 0:00
Valve #4 set for G0:00 
Valves #1-4 grouped with runtime of 20 minutes 
Valve #5 set for 0:10 minutes 
Valve #5 with runtime of 10 minutes
Valve #6 set for 0:15 minutes 
Valve #6 with runtime of 15 minutes
Valve #7 set for 0:25 minutes 
Valve #8 set for G0:00 or 0:00
Valve #9 set for G0:00 or 0:00
Valve #10 set for G0:00
Valves #7-10 grouped with runtime of 25 minutes 

It is possible to set more than one group.

NOTE

: When selecting or changing a grouped program, cycle through all the valves on the

program to save the changes before you exit.  

If a program is uploaded or changed and an error was
made, you will see the errors in one or more of these 3
screens. If no errors were made, none of these 3 screens
will appear.

If any changes have been made, the handset will establish
a link with a LEIT controller, which has the same Controller
ID number. While the word Connect is blinking, wait for a
confirmation. After communication is established, the new
settings (if revised) are uploaded. The following screens
will confirm the changes on the controller. If communication is not established the No Response-
Try Again screen will appear with Yes highlighted as the default. Press 

again to re-initiate

communication with a LEIT controller that has the same ID.

Program Number #1 is the default program. This screen
confirms that controller ID #09 has selected an additional
program.

This screen confirms that controller ID #09 has accepted a
schedule, run time or duration changes in the program.

Prog1 Time More
than 24 Hours

OK

Prog1  Start2
Before Start1

OK

Prog1 Overlaps
Start 2

OK

Connect ID: 12
Controller:

OK

Changed Ctrl:09
Active Progs.

OK

Changed Ctrl:09
Prog.1 Schedule OK

Содержание LEIT Link

Страница 1: ...I N S T R U C T I O N M A N U A L Website E http www digcorp com e mail dig digcorp com 041906 DIG CORP 26 401 Printed in the USA 1210 Activity Drive Vista CA 92081 USA Controller Group ID ID Locatio...

Страница 2: ...tered trademarks LEIT XRC LEIT Link Master and LEIT Link Multi Pro are each trademarks of DIG Corporation FCC compliance Important Note To comply with FCC RF exposure compliance requirements the anten...

Страница 3: ...rates 99 controllers in one group The LEIT Link Remote Control Handset is a 2 way radio communication device that operates in the ISM band 902 928 MHz 868 869 Europe The LEIT Link is a practical solut...

Страница 4: ...INK HANDSET AND LEIT XRC CONTROLLER IMPORTANT In order to establish 2 way communication between the LEIT Link handset and the LEIT XRC controllers a simple set up process using Radio Setup in both uni...

Страница 5: ...n entered into the controller The handset can be used to modify this description which is described later in detail in the Uplink System section Press to continue 5 To set the time for the handset und...

Страница 6: ...ed with the LEIT key and if any other handsets are active Press to review each screen and to exit If the LEIT XRC controller has no activity the first screen on the right indicates that the controller...

Страница 7: ...to the next feature SETTING UP A MONTHLY BUDGET FOR ALL PROGRAMS Instead of changing the duration for each program you can use the Uplink Monthly Budget feature to increase or decrease the amount of...

Страница 8: ...K Valve01 Use This YR 06 1682 34 OK YR 05 TOT Valve 0Yes 0No OK Valve01 Use last YR 05 1040 66 OK Total Use Last YR 05 3010 86 OK NOV05 Tot Valve 0Yes 0No OK DEC05 Tot Valve 0Yes 0No OK Connect ID 12...

Страница 9: ...he watering time for this group leader will be applied to all consecutive valves that show the letter G in the Valve Runtime screen Valve 01 0 02 Start OK Valve 2 G0 00 Runtime OK Valve 1 0 12 Runtime...

Страница 10: ...t2 next Sched 12 50pm OK UPLINK SETUP SYSTEM Connect ID 09 Controller OK 15 To remove the letter G from a valve in the group In the Valve Runtime screen press the or to underscore the letter G icon lo...

Страница 11: ...cation in which the sensor is connected via the SKIT 8821 4 adapter Active CCT Test 0Short 0Open OK Valve01 Options 0MV P Budget OK Sensor Location 0 MV P 0Other OK Sensor In Use 0 Yes 0 No OK Active...

Страница 12: ...is blinking wait for a confirmation If communication is established the following screens will confirm the changes If communication is not established the No Response Try Again screen will appear with...

Страница 13: ...ranty your product might be eligible for 21 SERVICE CALL INSTALLATION TROUBLESHOOTING CHECK THE LEIT CONTROLLER AND HANDSET 1 The LEIT XRC controller functions exactly the same as the LEIT X and LEIT...

Отзывы: