Preparatory measures
Close the ball valve.
Unscrew the plug screw from the ball valve.
Installation (see fig. II)
1.
Place the O-ring from the attached coupling set (type A or B) on the
mounting pin.
2.
Insert the O-ring with the mounting pin into the sensor hole of the ball
valve (turn the mounting pin).
3.
Position the O-ring in its final position using the other end of the
mounting pin.
4.
Fastening screws
Type A (plastic) - put the fastening screw onto the temperature sen-
sor.
Type B (brass) - slide the fastening screw onto the temperature sen-
sor and attach the fastening screw with the dowel pin. Press in the
dowel pin completely and remove the mounting pin from the temper-
ature sensor.
5.
Insert the temperature sensor with adapter fitting into the ball valve
and tighten fastening screw by hand (2-3 Nm).
4.2 Installation in a pocket
In case of new installations, temperature sensors for nominal sizes DN25
or smaller should only be installed immersed.
This ensures higher measuring accuracy.
5.
Power supply
5.1 Battery
A 3.6 VDC lithium battery is fitted in the standard version.
The battery must not be recharged or short-circuited.
Ambient temperatures below 35 °C have a positive effect on battery
lifetime.
Used batteries must be disposed of at suitable waste collection
points! Caution: Risk of explosion if battery is replaced by an
incorrect type.
Содержание Sharky 775
Страница 67: ...67 12 1 DMDE CE 101 5 Deutsch English Fran ais Espa ol...
Страница 68: ...68 Deutsch English Fran ais Espa ol...
Страница 69: ...69 12 2 DMDE CE 144 7 Deutsch English Fran ais Espa ol...
Страница 70: ...70 Deutsch English Fran ais Espa ol...
Страница 71: ...71 12 3 DMDE NEV 418 Deutsch English Fran ais Espa ol...