background image

 3 

PERSOnAL PRECAUtIOnS

2. 

RISK OF EXPLOSIvE GASES. A 

SPARK nEAR tHE BAttERY MAY 

CAUSE A BAttERY EXPLOSIOn. 

tO REDUCE tHE RISK OF A 

SPARK nEAR tHE BAttERY:

Working in the vicinity of a lead-acid battery is dangerous. Batteries generate 

2.1 

explosive gases during normal battery operation. For this reason, it is of 

utmost importance that you follow the instructions each time you use the  

jump starter.
NEVER smoke or allow a spark or flame in the vicinity of a battery or engine.

2.2 

do not permit the internal battery of the jump starter to freeze. Never charge a 

2.3 

frozen battery. 
To prevent sparking, NEvER allow clips to touch together or contact the same 

2.4 

piece of metal.
When charging the internal battery of the jump starter, work in a well ventilated 

2.5 

area and do not restrict the ventilation in any way.
Be extra cautious to reduce the risk of dropping a metal tool onto a battery. It 

2.6 

might spark or short-circuit the battery or other electrical part that may cause 

an explosion.
Remove personal metal items such as rings, bracelets, necklaces and watches 

2.7 

when working with a lead-acid battery. A lead-acid battery can produce a short-

circuit current high enough to weld a ring or the like to metal, causing a  

severe burn.
Be sure the area around the battery is well ventilated while the jump starter is 

2.8 

being used.

RISK OF COntACt WItH BAttERY ACID. 

BAttERY ACID IS A HIGHLY CORROSIvE 

SULFURIC ACID.

Consider having someone close enough by to come to your aid when you work 

2.9 

near a lead-acid battery.
Have plenty of fresh water and soap nearby in case battery acid contacts your 

2.10 

skin, clothing or eyes.
Wear complete eye and body protection, including safety goggles and 

2.11 

protective clothing. Avoid touching your eyes while working near the battery.
If battery acid contacts your skin or clothing, immediately wash the area with 

2.12 

soap and water. If acid enters your eye, immediately flood the eye with cold 

running water for at least 10 minutes and get medical attention right away.
If battery acid is accidentally swallowed, drink milk, the whites of eggs or water. 

2.13 

dO NOT induce vomiting. Seek medical attention immediately.
Stay clear of fan blades, belts, pulleys and other parts that may cause injury.

2.14 

Clean the battery terminals before using the jump starter. during cleaning, 

2.15 

keep airborne corrosion from coming into contact with your eyes, nose and 

mouth. Use baking soda and water to neutralize the battery acid and help 

eliminate airborne corrosion. do not touch your eyes, nose or mouth.
determine the voltage of the battery by referring to the vehicle owner’s manual 

2.16 

and make sure that the output voltage of the jump starter is correct.
Make sure that the jump starter cable clips make tight connections.

2.17 

Содержание 28.71486

Страница 1: ...DC Power Source Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Read and follow all Safety Rules and Operating Instructions before Every Use of this Product Save these instructions...

Страница 2: ......

Страница 3: ...ENANCE INSTRUCTIONS 8 Moving and STORAGE INSTRUCTIONS 8 TROUBLESHOOTING 9 SPECIFICATIONS 9 REPLACEMENT PARTS accessories 9 DieHard ONE Year Full Warranty When operated and maintained according to all...

Страница 4: ...result in death or serious injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in death or serious injury to the operator or bystanders I...

Страница 5: ...18 gauge AWG or larger and is 50 feet long or less To reduce the risk of electric shock turn off and or unplug the jump starter 1 7 before attempting any maintenance or cleaning Simply turning off the...

Страница 6: ...l ventilated while the jump starter is 2 8 being used RISK OF CONTACT WITH BATTERY ACID BATTERY ACID IS A HIGHLY CORROSIVE SULFURIC ACID Consider having someone close enough by to come to your aid whe...

Страница 7: ...3 5 If the negative post is grounded to the chassis as in most vehicles see step 3 6 If the positive post is grounded to the chassis see step 3 7 For a negative grounded vehicle connect the POSITIVE...

Страница 8: ...rger Plug 5 12V Accessory Plug 6 1 2 3 4 6 5 Charging the internal battery of the Jump starter 7 Important charge immediately after purchase after each use and every 30 days to keep the jump starter I...

Страница 9: ...harging Using this method to charge the battery overrides the maintain mode and the battery can be overcharged Monitor the progress of the battery and when it reaches a full 100 charge disconnect the...

Страница 10: ...load occurs The DC power outlet is wired directly to the internal battery Extended operation of a 12V DC device may result in excessive battery drain Recharge immediately after unplugging the 12V DC d...

Страница 11: ...come in contact with each other To prevent accidental arcing always keep the clips on the storage holders when not using it to jump start a vehicle If the jump starter is moved around the shop or tran...

Страница 12: ...harge status by pressing the button on the front of the jump starter See LED Indicators section of this manual Disconnect the 12V device The internal breaker will automatically reset after a minute or...