background image

 

9

 

7. 

Connect the charger to an electrical 

outlet.

8. 

Select the battery type and charge rate.

9. 

When charging is complete, 

disconnect the charger from the AC 

power, remove the clamps from the 

vehicle’s chassis, and then remove 

the clamp from the battery terminal.

CHARGING A BATTERY OUTSIDE  

OF THE VEHICLE

1. 

Place battery in a well-ventilated area.

2. 

Clean the battery terminals.

3. 

Connect the battery, following the 

precautions listed in sections 6 and 7.

4. 

Connect the charger to the electrical 

outlet.

5. 

Select the battery type and charge rate.

6. 

When charging is complete, 

disconnect the charger from the AC 

power, disconnect the negative clamp, 

and finally the positive clamp.

7. 

A marine (boat) battery must be 

removed and charged on shore.

AUTOMATIC CHARGING MODE

When an Automatic Charge is performed, 

the charger switches to the maintain mode 

automatically after the battery is charged. 

ABORTED CHARGE

If charging cannot be completed normally, 

charging will abort. When charging aborts, 

the charger’s output is shut off and the 

CHARGING (yellow/orange) LED will 

flash. The digital display will show an error 

code (see the Troubleshooting section 

for a description of the error codes). To 

reset after an aborted charge, unplug the 

charger from the AC outlet, wait a few 

moments and then plug it back in.

DESULFATION MODE

Desulfation could take 8 to 10 hours. If 

desulfation fails, charging will abort and the 

CHARGING (yellow/orange) LED will flash.

COMPLETION OF CHARGE

Charge completion is indicated by the 

CHARGED/MAINTAINING (green) LED. 

When lit, the charger has switched to the 

maintain mode of operation. 

MAINTAIN MODE  

(FLOAT-MODE MONITORING)

When the CHARGED/MAINTAINING 

(green) LED is lit, the charger has 

started maintain mode. In this mode, the 

charger keeps the battery fully charged 

by delivering a small current when 

necessary. If the charger has to provide 

its maximum maintain current for a 

continuous 12 hour period, it will go into 

abort mode (see Aborted Charge section). 

This is usually caused by a drain on the 

battery or the battery could be bad. Make 

sure there are no loads on the battery. If 

there are, remove them. If there are none, 

have the battery checked or replaced. 

MAINTAINING A BATTERY

The 28.71325 charges and maintains  

6 and 12 volt batteries, keeping them at 

full charge.

NOTE:

 The maintain mode technology 

allows you to safely charge and maintain 

a healthy battery for extended periods 

of time. However, problems with the 

battery, electrical problems in the 

vehicle, improper connections or other 

unanticipated conditions could cause 

excessive current draws. As such, 

occasionally monitoring your battery and 

the charging process is required.

USING THE ENGINE START SETTING

Your battery charger can be used to jump 

start your car if the battery is low. Follow 

all safety instructions and precautions for 

charging your battery. Wear complete eye 

protection and clothing protection. 

WARNING:

 Using the ENGINE START 

setting WITHOUT a battery installed in 

the vehicle could cause damage to the 

vehicle’s electrical system. 

NOTE:

 If you have charged the battery 

and it still will not start your car, do not 

use the Engine Start setting, or it could 

damage the vehicle’s electrical system. 

Have the battery checked.

1. 

With the charger unplugged from the 

AC outlet, connect the charger to the 

battery, following the instructions given 

in the CHARGING A BATTERY IN 

THE VEHICLE section.

2. 

With the charger plugged in and 

connected to the battery and chassis, 

press the RATE SELECTION button 

until the ENGINE START LED is lit. 

3. 

Crank the engine until it starts or 3 

seconds pass. If the engine does not 

start, wait 3 minutes before cranking 

again. This allows the charger and 

battery to cool down.

NOTE: 

During extremely cold weather,  

or if the battery is under 2 volts, charge 

the battery for 5 minutes before cranking 

the engine.

4. 

If the engine fails to start, charge the 

battery for 5 more minutes before 

attempting to crank the engine again.

5. 

After the engine starts, unplug the AC 

power cord before disconnecting the 

battery clamps from the vehicle.

Содержание 28.71325

Страница 1: ...er Cargador de baterías 6V 12V y arrancador OPERATOR S MANUAL MANUAL DEL USUARIO CAUTION Read and follow all safety rules and operating instructions before every use of this product SAVE THESE INSTRUCTIONS ATENCIÓN Lea y siga todas las reglas de seguridad e instrucciones de uso antes de cada uso de este producto GUARDE ESTAS INSTRUCCIONES ...

Страница 2: ...ates IL 60179 PARA ASISTENCIA AL CLIENTE O REPUESTOS LLAME GRATIS AL 7 AM 5 PM CT LUNES A VIERNES 1 800 SEARS 64 1 800 732 7764 DIEHARD THREE YEAR FULL WARRANTY When operated and maintained according to all supplied instructions if this DieHard product fails due to a defect in material or workmanship within 3 years from the date of purchase return it to any DieHard outlet in the United States for ...

Страница 3: ...TION PRECAUTIONS 6 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE 6 FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE 7 GROUNDING AND AC POWER CORD CONNECTIONS 7 ASSEMBLY INSTRUCTIONS 7 CONTROL PANEL 7 OPERATING INSTRUCTIONS 8 MAINTENANCE AND CARE 11 TROUBLESHOOTING ERROR CODES 11 BEFORE RETURNING FOR REPAIRS 13 ...

Страница 4: ...STRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary marking on these products and on engine 1 11 Pursuant to California Proposition 65 this product contains chemicals known to the State of California to cause c...

Страница 5: ...off position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in the sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY 6 1 Position AC and DC cords to reduce risk of damage by hood door or ...

Страница 6: ...Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United States is not recommended and should not be used USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of extension cord must be the same number size and shape as those of plug on charger Ensure that the e...

Страница 7: ...caps and are often marked low maintenance or maintenance free This type of battery is designed to deliver quick bursts of energy such as starting engines and has a greater plate count The plates are thinner and have somewhat different material composition Standard batteries should not be used for deep cycle applications AGM The Absorbed Glass Mat construction allows the electrolyte to be suspended...

Страница 8: ...go into abort mode see Aborted Charge section This is usually caused by a drain on the battery or the battery could be bad Make sure there are no loads on the battery If there are remove them If there are none have the battery checked or replaced MAINTAINING A BATTERY The 28 71325 charges and maintains 6 and 12 volt batteries keeping them at full charge NOTE The maintain mode technology allows you...

Страница 9: ...attery voltage reading a false surface charge may mislead you Compare the reading to the following chart 6 V Battery Voltage Reading 12 V Battery Voltage Reading Battery Condition 6 4 or more 12 8 or more Charged 6 1 to 6 3 12 2 to 12 7 Needs charging Less than 6 1 Less than 12 2 Discharged TESTER AND CHARGER When first turned on the unit operates only as a tester not as a charger Selecting a char...

Страница 10: ...ng to charge a large battery or bank of batteries on too low of a current setting Try again with a higher current setting or have the battery checked or replaced F05 The charger was unable to keep the battery fully charged in maintain mode The battery won t hold a charge May be caused by a drain on the battery or the battery could be bad Make sure there are no loads on the battery If there are rem...

Страница 11: ...ng The charger is in abort mode See Aborted Charge in the OPERATING INSTRUCTIONS Section Short or no start cycle when cranking engine Drawing more than the engine start rate Failure to wait 3 minutes between cranks Clamps are not making a good connection AC cord and or extension cord is loose No power at receptacle The charger may be overheated Battery may be severely discharged Crank time varies ...

Страница 12: ... the cables to the clamps and from the clamps to the battery system The clamps must be clean When an UNKNOWN OPERATING PROBLEM arises please read the complete manual and call the customer service number for information This will usually eliminate the need for return If the above solutions do not eliminate the problem or for information about troubleshooting or replacement parts call toll free from...

Отзывы: