INSTRUCTIONS:
EKOS M1 230
TECHNICAL SPECIFICATIONS
Voltage
Power
Accessory power output
Automatic closing time
Operating time
Slowing time
Courtesy light time
Number of codes
Transmitters
Frequency
Operating temperature
Sensibility
Homologation
220 VAC +/- 10%
550 W
24 VAC 250mA
5 to 120 sec
3 to 120 sec
2 to 120 sec
2 to 180 sec
254 codes
Fix\Rolling code
433.92 / 868 Mhz
0 to 70°C
–100dBm
Conf ETS 300-220/ETS 300
-683
Terminals Type
Description
1 - 2com
NO
START contact (Alternate Pulse OPEN/STOP/CLOSE/STOP)
3 - 2com
NO
PEDESTRIAN contact
4 - 6com
NC
BAND/PHOTOCELL OPENING contact (If you do not use it, please close the contact)
5 - 6com
NC
PHOTOCELL CLOSING contact (If you do not use it, please close the contact)
7 - 6com
NC
STOP contact (If you do not use it, please close the contact)
9 - 8com
NC
LIMIT SWITCH OPENING contact
10 - 8com
NC
LIMIT SWITCH CLOSING contact
11 - 12
24V ~
Phot accessories 24VAC 250mA power
13-14-15
220V ~ MOTOR input (
13-14
electrical phases with a capacitor in parallel) (
15
neutral/common)
16 - 18
220V ~ FLASHING LIGHT input
17 - 18
220V ~ COURTESY LIGHT input
19 - 20
220V ~ LINE input 220VAC
21 - 22
ANTENNA input (21 joiner / 22 signal)
L1
STATUS Led
On when the control panel is powered
L2
RADIO Led
On when you log in the radio memory
L3
PROGRAMMING TIME
Led
The led flashes during the programming
L4
START Led
On when you give a pulse
L5
PEDESTRIAN Led
On when you give a pedestrian pulse
L6
PHOTOCELL Led
On when the potocells are aligned
L7
L. S. OPENING Led
On when the limit switch is in N.C.
L8
L. S. CLOSING Led
On when the limit switch is in N.C.
L7+L8 STOP Led
Both on when the stop is in N.C.
LED READING
JUMPER J1
Radio memory opening by transmitter.
(Possibility of storing from the ou-
tside the transmitters without operating on the control panel).
Insert jumper:
ON
OFF
TRIMMER T1
The
Power
Trimmer regulates the pair and the sensitivity in normal operation.
TRIMMER T2
The
Power Slow
Trimmer regulates the pair and the sensitivity in slowing.
-
+
The pair increases turning the trimmer in clockwise.
BUTTON P1
RADIO PROG
button for the storage of the transmitters
BUTTON P2
TIME PROG
button for the storage of the operating time
P1
P2
J1
T1
T2
L4 L5 L6 L7 L8
L2
L3
COM
N.C.
N.C
.
N.C.
N.O.
N.O.
1234
5678
L1
N.C.
COM
N.C.
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20
COM
21
2
2
SELECTION
OPTIONS 1-8
P2
v M 01022012