OPTION
1
GARAGE / SLIDING SECTION
ON
Garage (2 sec pressure in more after the L.S. closing)
OFF
Sliding
OPTION
2
AUTOMATIC CLOSING
ON
Inserted automatic closing
OFF
Not inserted automatic closing
OPTION
3
RESIDENTIAL MODE / STEP BY STEP
ON
The automation always stops the operation to the limit switch: in
the opening movement it does not accept pulses; in the closing move-
ment it causes the inversion of the direction.
OFF
For each pulse the automation stops. With the
dip 2 ON
during the
closing movement a pulse causes the inversion of direction.
OPTION
4
INVERSION OF DIRECTION
ON
Inverts the direction of movement of the motor with its L.S.
OFF
Inverts the direction of movement of the motor with its L.S.
OPTION
5
SETUP OF THE SAFETY CONTACT IN OPENING
ON
Opening safety operation: the control panel stops the movement and
inverts it for 2 sec
OFF
Opening safety operation: the control panel stops the movement
OPTION
6
FLASHING LIGHT FUNCTION
ON
Intermittent light
OFF
Fixed light
OPTION
7
SLOWING
ON
Inserted slowing
OFF
Not inserted slowing
OPTION
8
ENCODER
ON
Active Encoder input
OFF
Not active Encoder input
GENERAL
The panel EKOS M1 230 is a control unit for sliding door, garage door and road barrier systems at 230Vac. This control panel
can manage motors with or without limit switch, with encoder and e limit switch.
The peculiarity of the EKOS M1 230 is the
regulation of separated pair, using the T1 and T2 trimmers (T1 regulates the pair during the opening time in normal speed
and T2 regulates the pair in the slowing).
Interacting on these control panels you can optimize the operation of the automatism
within the parameters of the existing regulations. The self-learnig programming of the operating time and the transmitters simplifies the
procedure of installation.
In case of management by ENCODER (OPTION 8 ON) the security is guaranteed by mechanical photocells / bands and enco-
der system: in presence of obstacles the opening operation is inverted or blocked.
With the not active ENCODER (OPTION 8 OFF)
you do not have the inversion of direction but only the control of the pair using
the trimmer T1 and T2.
TRANSMITTER PROGRAMMING
The control panel can manage fixed and rolling code transmitters. The two systems can not be manged simultaneously; the
first programmed transmitter encodes the radio software.
The EKOS M1 230 can manage 254 transmitters.
Press the button
P1
for 2 sec
, the
led L2 flashes, then press the button of the transmitter: the led L2 will flash twice to indicate that the
transmitter has been stored. After 6 sec the control panel will automatically exit from the programming function.
PEDESTRIAN PASSAGE PROGRAMMING (by transmitter)
Press the button
P1 for 2 sec, release it and press it again for 1 sec
, the led L2 starts to flash and for each pressure of the button of
a transmitter there is a quick double flash of the led L2. After 6 sec the control panel will automatically exit from the programming fun-
ction.
The operating time of the pedestrian passage is 8 sec.
STORED CODES DELETING
Press the button
P1 for 6 sec:
when you release it, there is a quick flash of the led L2; after 6 sec it will be off.
OPENING TIME PROGRAMMING
The programming starts when the automation system is closed: the first operation is the opening; if not, invert the direction
of movement using the dip 4.
PROGRAMMING WITHOUT SLOWING (OPTION 7 OFF)
Set the option 7 to OFF for the exclusion of the slowing. Follow the above-mentioned instructions (programming with slowing) without
sending the second pulse for the elimination of the slowing in the opening operation and the fourth pulse for the elimination of the slo-
wing in the closing operation. Then the pulses transmitted for the start of the operations will stop to the limit switch.
PROGRAMMING WITH SLOWING (OPTION 7 ON)
Pulse =
Wired start or Channel 1 of the transmitter
To enter in programming mode, press the P2 button for 2 seconds; the LED 3 will flash, then:
1. Give a
first pulse
: the gate starts the opening operation.
2. Give a
second pulse
where you want to start the slowing operation.
3. The gate stops the operation to the limit switch. (If you use an automation without FC, give a pulse to stop the operation)
4.
After stopping the opening operation, it will start the PAUSE storage in sec.
5. After your desired time interval, give a
third pulse
: the gate starts the closing operation.
6. Give a
fourth pulse
where you want to start the slowing operation.
7. The gate stops the operation to the limit switch. (If you use an automation without FC, give a pulse to stop the operation)
8. When the led 3 is off you have finished the programming.
ENCODER OPERATION
The encoder input is programmed using the
OPTION 8
,
CHANGE OF SENSITIVITY ACCORDING TO THE PAIR
More pair = Less sensitivity
Less pair = More sensitivity
The parameters are regulated using the T1 and T2 TRIMMER.
OPTIONS SELECTION USING THE DIP-SWICHT