background image

OPTION 

GARAGE / SLIDING SECTION 

 

ON 

Garage (2 sec pressure in more after the L.S. closing) 

 

OFF 

Sliding 

OPTION 

AUTOMATIC CLOSING 

 

ON 

Inserted automatic closing 

 

OFF 

Not inserted automatic closing 

OPTION 

3  

RESIDENTIAL MODE / STEP BY STEP 

 

ON 

The automation always stops the operation to the limit switch: in 
the opening movement it does not accept pulses; in the closing move-
ment it causes the inversion of the direction. 

 

OFF 

For each pulse the automation stops. With the 

dip 2 ON 

during the 

closing movement a pulse causes the inversion of direction. 

OPTION 

INVERSION OF DIRECTION 

 

ON 

Inverts the direction of movement of the motor with its L.S. 

 

OFF 

Inverts the direction of movement of the motor with its L.S. 

OPTION 

SETUP OF THE SAFETY CONTACT IN OPENING 

 

ON  

Opening safety operation: the control panel stops the movement and 
inverts it for 2 sec 

 

OFF 

Opening safety operation: the control panel stops the movement

 

OPTION 

FLASHING LIGHT FUNCTION 

 

ON 

Intermittent light  

 

OFF 

Fixed light 

OPTION 

SLOWING 

 

ON 

Inserted slowing 

 

OFF 

Not inserted slowing 

OPTION 

ENCODER 

 

ON 

Active Encoder input 

 

OFF 

Not active Encoder input 

GENERAL 

The  panel  EKOS  M1  230  is  a  control  unit  for  sliding  door,  garage  door  and  road  barrier  systems  at  230Vac.  This  control  panel 
can manage motors with or without limit switch, with encoder and e limit switch. 

The peculiarity of the EKOS M1 230 is the 

regulation of separated pair, using the T1 and T2 trimmers (T1 regulates the pair during the opening time in normal speed 
and  T2  regulates  the  pair  in  the  slowing).

 Interacting on these control panels you can optimize the operation of the automatism 

within the parameters of the existing regulations. The self-learnig programming of the operating time and the transmitters simplifies the 
procedure of installation. 

In case of management by ENCODER (OPTION 8 ON) the security is guaranteed by mechanical photocells / bands and enco-
der system: in presence of obstacles the opening operation is inverted or blocked.  
With  the  not  active  ENCODER  (OPTION  8  OFF)

 you do not have the inversion of direction but only the control of the pair using 

the trimmer T1 and T2. 

 
TRANSMITTER PROGRAMMING 

The control panel can manage fixed and rolling code transmitters. The two systems can not be manged simultaneously; the 
first programmed transmitter encodes the radio software.

 

The EKOS M1 230 can manage 254 transmitters. 
 
Press the button 

P1

 

for 2 sec

, the

 

led L2 flashes, then press the button of the transmitter: the led L2 will flash twice to indicate that the 

transmitter has been stored. After 6 sec the control panel will automatically exit from the programming function.  

 
PEDESTRIAN PASSAGE PROGRAMMING (by transmitter)  

Press the button 

P1 for 2 sec, release it and press it again for 1 sec

, the led L2 starts to flash and for each pressure of the button of 

a transmitter there is a quick double flash of the led L2. After 6 sec the control panel will automatically exit from the programming fun-
ction. 

The operating time of the pedestrian passage is 8 sec. 

 

 
STORED CODES DELETING 

Press the button

 P1 for 6 sec: 

when you release it, there is a quick flash of the led L2; after 6 sec it will be off. 

 
OPENING TIME PROGRAMMING 

The programming starts when the automation system is closed: the first operation is the opening; if not, invert the direction 
of movement using the dip 4. 

 

 

PROGRAMMING WITHOUT SLOWING  (OPTION 7 OFF) 

 
Set the option 7 to OFF for the exclusion of the slowing. Follow the above-mentioned instructions (programming with slowing) without 
sending the second pulse for the elimination of the slowing in the opening operation and the fourth pulse for the elimination of the slo-
wing in the closing operation. Then the pulses transmitted for the start of the operations will stop to the limit switch. 

PROGRAMMING WITH SLOWING  (OPTION 7 ON) 

 
Pulse = 

Wired start or Channel 1 of the transmitter

 

To enter in programming mode, press the P2 button for 2 seconds; the LED 3 will flash, then: 
 

1. Give a 

first pulse

: the gate starts the opening operation. 

2. Give a 

second pulse 

where you want to start the slowing operation. 

3. The gate stops the operation to the limit switch. (If you use an automation without FC, give a pulse to stop the operation) 
4. 

After stopping the opening operation, it will start the PAUSE storage in sec.

 

5. After your desired time interval, give a 

third pulse

: the gate starts the closing operation. 

6. Give a 

fourth pulse 

where you want to start the slowing operation. 

7. The gate stops the operation to the limit switch. (If you use an automation without FC, give a pulse to stop the operation) 
8. When the led 3 is off you have finished the programming. 

ENCODER OPERATION 

 The encoder input is programmed using the 

OPTION 8

,  

CHANGE OF SENSITIVITY ACCORDING TO THE PAIR 

More pair   =   Less sensitivity 
Less pair   =   More sensitivity 

The parameters are regulated using the T1 and T2 TRIMMER.

 

OPTIONS SELECTION USING THE DIP-SWICHT 