Display Commands
9.2.4
9.2.4
Status Bytes Definitions
Status
Byte
Bit
Error Message
1
0
Flash download in progress
1 … 3
Error status
000 – No error
001 – Device received unexpected command
010 – File ist not valid
011 – Device is unable to read from memory
100 – Device is unable to read from memory
101 - Programm memory failed verification
110 – Vendor-specific error
111 – Unknown error
4
Reserved (must be zero)
5
Hardware error
6
Command not executed
7
Device not ready to receive command
2
0
Command complete
1
Flash download is in progress
2 … 4
Firmware upgrading status
5
Next segment pending (1.)
6
Operation Error
7
Undefined command
3
0 … 7
Reserverd (all zero)
Notes:
1.
Bit 5 of Status Byte 2 when set indicates that there is another
Segment
following this. A zero for this
bit means that there is no subsequent segment. As the byte-count is a byte value, when the amount
of data exceeds the 255 (0xFF) it has to be broken up into two or more
Segments
. A
Segment
is a
block of data that starts with the byte-count and the 3 status bytes followed by the data. The Host
software will have to combine the data from each segment to form a complete data transfer.
Copyright © 2022, Diebold Nixdorf
01750364416 B
9-18
Содержание D1064
Страница 59: ...Technical Data D1064 Stand Dimensions TD 01596 33 Copyright 2022 Diebold Nixdorf 01750364416 B 10 3...
Страница 60: ...Technical Data Pole Adapter Dimensions TD 01596 36 Copyright 2022 Diebold Nixdorf 01750364416 B 10 4...
Страница 61: ...Technical Data D1064 A Series AIO Adapter TD 01596 34 Copyright 2022 Diebold Nixdorf 01750364416 B 10 5...