Display Commands
9.2.3.3
9.2.3.3
Request Status
Command
00h, 20h
Response
04h, <Status byte 1>, <Status byte 2>, <Status byte 3>
Description:
This command returns its status to the display.
9.2.3.4
9.2.3.4
Reset
Command
00h, 40h
Response
none
Description:
This command causes a software reset of the device.
9.2.3.5
9.2.3.5
Read Display Identification
Command
21h, 00h
Response
<count>, <Status byte 1>, <Status byte 2>, <Status byte 3>, <Pn1> ; <Pn2> ; <Pn3> ;
<Pn4> ; <Pn5> ; <Pn6> ; <Pn7>
count
1-Byte value representing bytes count of the following data (w/o ‘count’ byte)
Pn1
Type of display
Pn2
Current code page
Pn3
Country code
Pn4
Number of lines
Pn5
Columns per line
Pn6
Code page loaded in space page
Pn7
Serialnumber
Pn1 to Pn7 are string encoded in the current encoding mode, either in ASCII, UTF-8 or UTF-16.
Description:
This command is used to get display identification from the device.