3.1.3
Guidelines to Minimize Environmental Exposure
Use the following tips to minimize device exposure:
• Close (but do not lock) the upper chassis when using the operator's interface
to perform routine maintenance sessions.
• Minimize exposure time when the outside temperature is below +5° C (4°
F). A warm-up period can be avoided if required service can be performed
within the maximum allowable exposure times (refer to Table 3-1).
3.2
Switching the System to Maintenance Mode
The maintenance switch is used to switch the system between the default
operating mode and the maintenance mode (see Figure 2-18). Press the
maintenance switch to bring the system to the maintenance mode. Exit the
maintenance mode using the system software.
3.3
Accessing the Upper Chassis
3.3.1
Opening the Upper Chassis
Perform the following steps to open the fascia and access the upper chassis
modules:
1. Insert the key into the fascia access door key slot. See Figure 3-1
2. Turn the key clockwise.
3. Turn each fixed grip latch 90 degrees counterclockwise to open the fascia
access door. See Figure 3-1.
4. Insert the key into the fascia key slot. See Figure 3-1.
5. Turn the key clockwise to release the fascia latch.
6. Pull the fascia out into the service position.
7. Refer to your system control software documentation for information on
placing the system in the proper mode for maintenance.
8. Refer to the appropriate section to access the desired component.
9. Refer to the appropriate operating guide listed in Appendix A for
information on completing the maintenance procedures for your system
modules.