The Plug-In Configuration Menu 1 1
P 1
RCL
1
2
3
4 .
2
SAVE
1
2
3
4
3
PROG
1
2
n
n
>P1: 9
MORE
Supplemental Instructions For GP700 Modular With Two-Position
Prism Switch Plug-In
This section describes the operating instructions and NEW command set required for
any GP700M Modular Mainframe containing the Two-Position (Prism) Switch Plug-Ins.
WARNING
Do not install the Two-Position Switch Plug-In into GP700 Mainframes without a
triangular "Prism R e a d y label on the rear or with firmware version lower then Vesion
2.12. The Two-Position Switch Plug-In is identified by a P/N starting with "PS-" which is
marked on the lower section of the connector faceplate. This device will NOT function
with any earlier version of the firmware. The firmware version is shown on the front
panel display upon power up. Contact DiCon if you wish to use this Plug-In in a GP700
Mainframe that does not fit this description.
FRONT PANEL OPERATION
a. A d d / D e l e t e
User can use the
PCFG
softkey to add/delete Pwo-Position PlugIns. The
procedure is identical to any other modular Plug In. It will display the current
module configuration when user adds in the module and allow the user to
accept it.
b. D i s p l a y and Moving Switches
The Two-Position Plug Ins are always displayed on the last page of the screen,
depending on if there are other types of Plug-Ins, the 'Next Page' button may
need to pressed several times to display the Two-Position Plug-Ins. The 'Next
Page' button is represented by two overlapping boxes located directly above
the PREV button.
The front panel will show a row four small boxes for each Plug In module. Each
small box stands for one switch, starting from 1 to 4. It will show "n" in the box
where there is no switch.
When the small box is
not
highlighted, the switch is in state 1, when the box
is
highlighted the switch is set to state 2. The figure below indicates that switch
number 4 in Plug-In number 1 is in State 2.
91507 Revision A3
M
a
r
c
h
11, 2005