background image

06 Extended Functions Menu

 

 

 

 

 

The Extended Functions Menu has another sub-menu showing several statistical values. 

There are two types of value-counters, either re-settable to zero or not.

 

The statistic counters are saved whenever the mod is automatically or manually 

switched off. In contrast, if the battery is removed from the mod before switching off, 

the changes of the counters since the device was most recently turned on.

 

 

 

 

 

The following statistical values are stored:

 

-

 

Cycles 

Number of puffs. The counter can be reset to 0.

 

-

 

Time 

The timespan during which power was applied to the coil, i.e. vaping time.

 

The counter can be reset to 0.

 

-

 

Energy  This is the energy consumption during vape in Joules=Watt-Seconds. This 

value is the true integrated vape power over time. It is the power integral, 

because during temperature controlled vaping (and also in bypass mode) 

the power is not constant, but varies a lot over time.  The counter can be 

reset to 0.

 

-

 

BatCap   If this counter is checked before a new battery is installed and is reset 

immediately after the insertion of a new battery the display will show the 

battery’s capacity.  This function allows the user to check whether a battery 

has the capacity declared by the manufacturer or  i f   a  battery is worn-out. 

This counter can be reset to 0. With stacked  batteries, the value shows the 

average capacity of the two.

 

-

 

TotCycl  “Total Cycles” is the number of puffs throughout the entire mod’s life.

 

It cannot be reset.

 

-

 

TotTime   “Total Time” is the total time of vaping (not stand by) in a format HHHH:MM 

that is 4 digits for hours and 2 for minutes. It cannot be reset.

 

The menu item 

Reset Ctr

, i.e. the resetting of the counters, is intentionally positioned 

between resettable counters and those which cannot be reset—making it easy to 

remember  which are resettable.

 

 

 

 

Remark about stacking: The efficiency of the system—battery and mod—is higher when using two batteries 

instead of one. In other words, the total vape time of a stacked-batteries mod is somewhat longer than two 

times the vape time of a single-battery mod. This is because the current at the same power output is half

 

for two batteries compared to one. Example: The current drained from a battery (with an inner resistance of 

70mOhms) at 10A generates a power loss of 7W during vape. A current of 5A drawn from two batteries (both 

with inner resistances of 70mOhm) generates a power loss of just 3.5W distributed to two batteries! 

Moreover, the voltage drop is half as much.

 

 

 

 

We recommend the following batteries for the dicodes 2380 and 2380T:

 

 

Samsung INR18650 25R 

LG ICR18650 Hd2

 

Sony Konion US18650UTC4

 

Содержание 2380

Страница 1: ...2380 2380T manual ...

Страница 2: ...ns a with different length tube pieces to have one 18350 or 18500 or 18650 battery or two stacked batteries of 2x 18350 or 2x 18500 2x 18650 is possible by using an optional extension tube b as a telescope version dicodes 2380T with additional tube pieces 5 to 40W with one Li Ion battery 5 to 80W with two Li Ion batteries Adjustable battery discharge level 2 5 3V and 6 2 6 8V Up to 12V output volt...

Страница 3: ...not displayed in Bypass Mode 2 with low no current Ub0 and high current load UbL Power Up Power Down 1 1 Heater Menu Temp Coefficient Down Power Limit Heater Protection Setting Power Boost Setting Mod Menu Display Luminosity Switch Off Time Power On Clicks Menu On Clicks Click Speed Half Wattage Temperature Unit C F Value Menu Vaping Time Energy Joule Wes Battery Capacitance Reset Counters Total L...

Страница 4: ... Re set to Defaults ...

Страница 5: ...rform a Manual Coil Temperature Calibration TempCal Init see next item Manual Coil Temperature Calibration This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below The Temperature calibration measures the coil resistance at room temperature 20 C as the reference for temperature controlled vaping The calibration must be confirmed by pressing t...

Страница 6: ...ce of 4 Ohms and a power setting of 40W the required voltage at the coil would be 12 7V but given the 12V limit he maximum wattage is 36W 12V 4R 36W Or if the coil resistance is 0 1 Ohm the maximum power is 22 5W because 15A 0 1 Ohm 22 5W With high coil resistance the power is limited by the maximum voltage 12V and with low resistances the power is limited by the maximum current 15A These limits a...

Страница 7: ...ost because the average power is increased by the boosts and the temperature cycles through significantly higher ranges Wert Power Boost Boostzeit ms Zeit auf Nennleistung ms Effektive Leistung bei 5W Nennleistung 1 2 3 4 5 6 7 8 9 10 300 450 600 50 80 120 160 200 250 300 500 600 700 800 900 1000 1000 Start Boost Start Boost Start Boost 6 18 6 53 6 9 7 17 7 36 7 6 8 0 Note If the power setting equ...

Страница 8: ...f one battery is selected in the Extended Functions Stack Mode menu Value 1 and the input voltage exceeds 4 5V OvrVolt will be displayed With two batteries selected value 2 the error occurs for an input voltage 8 6V Reduce the input voltage to the specified range With stack mode set to 0 automatic detection the error is displayed for voltages 8 6V 1 ChkAtom No atomizer detected or open coil 2 Temp...

Страница 9: ...attery quality Reset the counters above Total lifetime puffs of mod Not resettable Total lifetime vaping time of mod in HHHH MM Not resettable Enablesautomatic temperature calibration when set to 1 3 Select number of batteries 0 automatic 1 single 2 dual battery Select display orientationbetween Left and Right handed Select Expert mode to enable power boost heater protection and bypass mode Switch...

Страница 10: ...pecify a minimum discharge level of 2 5V to 2 7V Since the voltage of a fully charged battery can quickly drop to 3 7V the protect your device the minimum power level allowed with two batteries installed is 6 2V If the user is unsure of the minimum discharge level of their battery the level should be set to 2 7V when using one battery or 6 4V when using two batteries The selected voltage is the vo...

Страница 11: ...one or two batteries In Stack Control Stack Ctrl the user can select automatic detection 0 of the numbers of batteries or manually select one or two batteries The number of batteries inserted is determined through a measurement of total voltage Manually setting 1 or 2 adds a safety margin for the system since it s a user might insert two discharged batteries both at 2 2V so the total voltage is 4 ...

Страница 12: ...declared by the manufacturer or if a battery is worn out This counter can be reset to 0 With stacked batteries the value shows the average capacity of the two TotCycl Total Cycles is the number of puffs throughout the entire mod s life It cannot be reset TotTime Total Time is the total time of vaping not stand by in a format HHHH MM that is 4 digits for hours and 2 for minutes It cannot be reset T...

Страница 13: ...en persons allergic to nicotine or propylene glycol or persons with cardiovascular disease Selling electronic cigarettes to persons under 18 years of age is prohibited Battery Disposal Li Ion batteries may not be disposed in household waste Customers are required by law to dispose of worn out batteries at appropriate collection sites Mod Disposal The symbol below indicates that this device should ...

Отзывы: