06 Extended Functions Menu
The Extended Functions Menu has another sub-menu showing several statistical values.
There are two types of value-counters, either re-settable to zero or not.
The statistic counters are saved whenever the mod is automatically or manually
switched off. In contrast, if the battery is removed from the mod before switching off,
the changes of the counters since the device was most recently turned on.
The following statistical values are stored:
-
Cycles
Number of puffs. The counter can be reset to 0.
-
Time
The timespan during which power was applied to the coil, i.e. vaping time.
The counter can be reset to 0.
-
Energy This is the energy consumption during vape in Joules=Watt-Seconds. This
value is the true integrated vape power over time. It is the power integral,
because during temperature controlled vaping (and also in bypass mode)
the power is not constant, but varies a lot over time. The counter can be
reset to 0.
-
BatCap If this counter is checked before a new battery is installed and is reset
immediately after the insertion of a new battery the display will show the
battery’s capacity. This function allows the user to check whether a battery
has the capacity declared by the manufacturer or i f a battery is worn-out.
This counter can be reset to 0. With stacked batteries, the value shows the
average capacity of the two.
-
TotCycl “Total Cycles” is the number of puffs throughout the entire mod’s life.
It cannot be reset.
-
TotTime “Total Time” is the total time of vaping (not stand by) in a format HHHH:MM
that is 4 digits for hours and 2 for minutes. It cannot be reset.
The menu item
Reset Ctr
, i.e. the resetting of the counters, is intentionally positioned
between resettable counters and those which cannot be reset—making it easy to
remember which are resettable.
Remark about stacking: The efficiency of the system—battery and mod—is higher when using two batteries
instead of one. In other words, the total vape time of a stacked-batteries mod is somewhat longer than two
times the vape time of a single-battery mod. This is because the current at the same power output is half
for two batteries compared to one. Example: The current drained from a battery (with an inner resistance of
70mOhms) at 10A generates a power loss of 7W during vape. A current of 5A drawn from two batteries (both
with inner resistances of 70mOhm) generates a power loss of just 3.5W distributed to two batteries!
Moreover, the voltage drop is half as much.
We recommend the following batteries for the dicodes 2380 and 2380T:
Samsung INR18650 25R
LG ICR18650 Hd2
Sony Konion US18650UTC4