background image

Ver

tic

al blin

d with 22

0V m

ot

or

www.diaz.be

4

V.

 2

0-0

1

Optional 

Add/delete additional remote control/channel.

Favorite position     (only RTS).

Soft reset of the motor.

Restore factory default (avoid!!!).

1

2

3

4

3 x

3 x

SHORT OPEN/CLOSE 

MOVEMENT 

SHORT OPEN/CLOSE 

MOVEMENT

OK

2SEC

PROG. A

PROG. B

COUPLED

ADDITIONAL 

PROG. A

PROG. B

3 x

SHORT OPEN/CLOSE 

MOVEMENT

UNTIL

5 SEC

PUT BLIND IN 

DESIRED POSITION

OK

OK

ON

230V

OFF

230V

5SEC

5SEC

Warning! If you press ‘P1’ longer than 5 sec.  
the motor will go back to factory settings. 

This is irreversible and cannot be solved 

 

without a programm-unit.