Diamond ML10/B5-VV/R2 Скачать руководство пользователя страница 6

15

be assembled by qualified people after the equip-

ment has been positioned on its place. The assem-

bling instructions are contained in the envelope that 

is supplied inside the packing.

The equipment has to be positioned on its definitive 
place and levelled by qualified people.

The unit is equipped with the plug and electrical cable 

mod. Schuco. It can also be a British G Type.

The cable has to be connected at 3 mt. max. to a 0,03A 

differential fused isolator. NEVER CONNECT THE CABLE 

TO MAIN SUPPLY LINE DIRECTLY.

Verify that the power supply voltage is as indicated on the 

machine rate plate (fig. C).

Power supply
230 V

50 Hz single phase

220 V

60 Hz

110 V

60 Hz

To ensure correct operation, the maximum voltage varia-

tion must be b/- 6% of the nominal value.

We recommend to connect the unit to a dedicated circuit 

and not to use damaged sockets, extension sockets or 

multiple sockets.

In case of incompatibility between the socket and the plug 

of the refrigerated cabinet, the plug should be replaced 

with a suitable one by a qualified technician.

For units with electric sockets the maximum rating is 1000 

W.

During the electrical connection it is forbidden:

- To use adapter sockets or extension sockets.

- To connect other appliances to the same power 

socket.

- To pull the electrical cable or the unit to unplug the 

equipment from the socket (fig. A).

- To use extension sockets, worn down cables, cables 

with damaged or fissured insulation as they are very 

dangerous: they could cause sparks, electric shock 

and fire.

- It is absolutely prohibited to pass cables and con-

nect other sockets under the cabinet.

During the electrical connection verify:

- The power supply cable has to be laid in such a way 

as to prevent it from being damaged or becoming 

hazardous to people and things.

- In case the power supply cable is damaged, it 

should be replaced only by a qualified technician 

(electrician) with an equivalent cable.

- The cable of the equipment should be checked re-

gularly. If it should result that the cable is damaged 

or deteriorated, disconnect the equipment and do 

not use it and let the cable be replaced with an ori-

ginal replacement part by an authorised technician.

- Protect the cable in such a way as to prevent twi-

sting or interlacement with other cables, trample on, 

crushing, stretching.

A wrong installation could cause damages to peo-

ple, animals or things, for which the manufacturer 

cannot be deemed responsible.

12. FIRST CAREFUL CLEANING

DURING THE WHOLE CLEANING OPERATION USE 

WORKING GLOVES OF CLASS II TO PROTECT 

YOUR HANDS ALL THE TIME AND THE PERSONAL 

PROTECTIVE EQUIPMENT ACCORDING TO THE 

LAW OF YOUR COUNTRY.

Before switching on the unit, take away the protective film 

that covers some external and internal parts of the cabinet 

(for example display surface, shelves, front decoration 

panels, etc.). Clean the refrigerated cabinet thoroughly, 

both inside and outside, using warm water (max. 30°C) 

and a solution of bicarbonate of soda (1 tea spoon every 

2 liters) or white vinegar. Carefully dry the unit with a soft 

cloth.

During the cleaning operation it is forbidden:

- To use detergent products, metal pads or abrasive 

substances that could damage the aesthetic appe-

arance of the equipment.

- To use sharp objects (any damage resulting from 

the use of these objects will not be covered by war-

ranty).

- To spray water directly on the electric parts and 

to wet the electrical parts (fans, lighting, electrical 

cables, etc.).

- To wash the refrigerated cabinet with water jets.

Once the cleaning is finished, switch the unit on through 

the ON/OFF switch and wait until the cabinet reaches 

the proper temperature for the products that have to be 

displayed. It will take approx. 3 hours for the cabinet 

to reach the proper temperature. The products to be 

displayed will have to be already cold according to the 

cabinet temperature.

To switch off the display:

- Set the thermostat to 0.

- Switch off using the ON/OFF switch.

- Turn off the light using the ON/OFF switch.

- Unplug the power cord.

- Wait five minutes.

- Clean the display.

Содержание ML10/B5-VV/R2

Страница 1: ...08 2021 Mod ML10 B5 VV R2 Production code PY104PSCND97H ...

Страница 2: ...Technical instructions SERVE OVER COUNTER ...

Страница 3: ...ter jets to allow children to use the equipment without adult supervision and make sure that they do not play with the equipment to start any cleaning or maintenance operation wi thout unplugging or disconnecting the equipment to cover the cabinet with clothes or other things du ring its working store combustible materials such as paper rags cloths chemicals etc on the surface under the unit the r...

Страница 4: ...ISO 23953 2006 and the refrigeration power has been calculated referring to the climatic class 3 The refrigerated unit maintains its performance characte ristics with an ambient temperature and relative humidity of no more than the ones indicated in the table ensuring maintenance personnel and generally to all the pe ople that for different reasons have to operate with the equipment It is forbidde...

Страница 5: ... of the unit and also to avoid higher energy During the installation procedure it is prohibited to Tilt the cabinet as the lubricating oil contained in the cabinet itself could enter the cold circuit and the latter could suffer irreparable damage Correct possible imperfections of the floor level with pieces of wood carton or similar but use only the feet screwing or unscrewing them without taking ...

Страница 6: ...nt cable The cable of the equipment should be checked re gularly If it should result that the cable is damaged or deteriorated disconnect the equipment and do not use it and let the cable be replaced with an ori ginal replacement part by an authorised technician Protect the cable in such a way as to prevent twi sting or interlacement with other cables trample on crushing stretching A wrong install...

Страница 7: ...g of the ice During this phase do not use any kind of sharp object to make the melting of the ice quicker because you could cause big damages to the equipment Once the ice is completely melted switch the equipment on through the ON OFF switch as indicated in paragraph 12 17 DEFROSTING The defrosting takes place automatically during the run ning of the unit The defrosting cycles are 6 a day and las...

Страница 8: ...nd or sharp tools which can damage the unit After every cleaning operation it is necessary to rinse with warm water and dry the unit with a soft and clean cloth Clean the condenser after having removed the cover grid with a dry paint brush do not use iron brushes or a vacuum cleaner removing all dust and possible deposits on the fins During the maintenance and cleaning pay attention not to bend or...

Страница 9: ...the laws of the country of installation WARNING DISPLAY COUNTERS FILLED WITH R290 REFRIGERANT The R290 refrigerant gas is compatible with the environ ment but highly flammable Pay the utmost attention du ring the transport installation and disposal of the counter to avoid damage to the pipes of the refrigerant circuit Keep the counter away from free flames or sources of ignition IN CASE OF DAMAGE ...

Отзывы: