the exchange of air in the environment even when the 

room is closed:

Max. allowed ambient 

temperature

R.H. Max allowed relative 

humidity

+25°C

60%

In case the ambient conditions are not included in 

the above mentioned ones, a lower performance 

must be expected.

The ambient where the equipment is installed has to be 

proper and in conformity with the hygienic and sanitary 

rules in force.

8. IDENTIFICATION – PLATE  DATA 

A serial plate is affixed behind the equipment, stating all 

its identification and characteristic data:

1) Manufacturer's name and address

2) Equipment name and description

3) Equipment code

4) Equipment serial number

5) Kind of refrigerant fluid

6) Mass of refrigerant gas with which the unit has been 

loaded (only for equipment with built-in motor)

7) Production year

8) Climatic class

9) Supply voltage and frequency

10) GWP

11) CO

2

13) Absorbed electrical power

14) Max. pressure inside the circuit

9. INSTALLATION

The equipment must be installed in a suitable, not windy 

place and on a level floor in order to prevent noise and 

vibrations during the working of the unit and also to avoid 
higher energy.

 

 

 

During the installation procedure, it is prohibited to:

- Tilt the cabinet, as the lubricating oil contained in 

the cabinet itself could enter the cold circuit and the 

latter could suffer irreparable damage.

- Correct possible imperfections of the floor level with 

pieces of wood, carton or similar, but use only the 

feet screwing or unscrewing them (without taking 

them off) until you reach a perfect levelling.

- Install the equipment near sources of heat such as 

radiators, direct or indirect sunlight or other equip-

ment which produce heat;

- Install the equipment in line with draughts coming 

from doors, windows, cooling fans or air-conditio-

ning systems.

- Close or obstruct the ventilation openings of the re-

frigerating unit, because this would stop the airflow 

which cools the refrigeration unit causing bad wor-

king.

10. ASSEMBLING

The equipment has to be completed according to the 

assembly instructions contained in the paper box coming 

along with the packaging. The appliance must be placed 

on the location and set by specialized personnel.

 
11. ELECTRICAL POWER/CONNECTION

The equipment has to be completed with the assem-

bling of the shelves and for some models also of the 

glasses that have to

C

2
3

5

6

13

9

8

10

11

14

7

4

1

Содержание ML10/B5-VV/R2

Страница 1: ...08 2021 Mod ML10 B5 VV R2 Production code PY104PSCND97H ...

Страница 2: ...Technical instructions SERVE OVER COUNTER ...

Страница 3: ...ter jets to allow children to use the equipment without adult supervision and make sure that they do not play with the equipment to start any cleaning or maintenance operation wi thout unplugging or disconnecting the equipment to cover the cabinet with clothes or other things du ring its working store combustible materials such as paper rags cloths chemicals etc on the surface under the unit the r...

Страница 4: ...ISO 23953 2006 and the refrigeration power has been calculated referring to the climatic class 3 The refrigerated unit maintains its performance characte ristics with an ambient temperature and relative humidity of no more than the ones indicated in the table ensuring maintenance personnel and generally to all the pe ople that for different reasons have to operate with the equipment It is forbidde...

Страница 5: ... of the unit and also to avoid higher energy During the installation procedure it is prohibited to Tilt the cabinet as the lubricating oil contained in the cabinet itself could enter the cold circuit and the latter could suffer irreparable damage Correct possible imperfections of the floor level with pieces of wood carton or similar but use only the feet screwing or unscrewing them without taking ...

Страница 6: ...nt cable The cable of the equipment should be checked re gularly If it should result that the cable is damaged or deteriorated disconnect the equipment and do not use it and let the cable be replaced with an ori ginal replacement part by an authorised technician Protect the cable in such a way as to prevent twi sting or interlacement with other cables trample on crushing stretching A wrong install...

Страница 7: ...g of the ice During this phase do not use any kind of sharp object to make the melting of the ice quicker because you could cause big damages to the equipment Once the ice is completely melted switch the equipment on through the ON OFF switch as indicated in paragraph 12 17 DEFROSTING The defrosting takes place automatically during the run ning of the unit The defrosting cycles are 6 a day and las...

Страница 8: ...nd or sharp tools which can damage the unit After every cleaning operation it is necessary to rinse with warm water and dry the unit with a soft and clean cloth Clean the condenser after having removed the cover grid with a dry paint brush do not use iron brushes or a vacuum cleaner removing all dust and possible deposits on the fins During the maintenance and cleaning pay attention not to bend or...

Страница 9: ...the laws of the country of installation WARNING DISPLAY COUNTERS FILLED WITH R290 REFRIGERANT The R290 refrigerant gas is compatible with the environ ment but highly flammable Pay the utmost attention du ring the transport installation and disposal of the counter to avoid damage to the pipes of the refrigerant circuit Keep the counter away from free flames or sources of ignition IN CASE OF DAMAGE ...

Отзывы: