![Diamond MCV/12C Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/diamond/mcv-12c/mcv-12c_manual_2493315015.webp)
English
Automatic cream-whipper
16
Z15.027
V01
The cream is not suitable with the labyrinth. Call the Assistance Service.
Cause:
Preservation temperature is too high. Call Assistance Service to adjust it.
Cause:
The refrigerating plant is damaged. Call the Assistance Service.
Cream comes out liquid from the outlet nozzle.
Cause:The air-inlet valve is obstructed. Disassemble and clean it as described in Section 6.
No cream dispensing (possible development of foam in the container). The pump’s motor seems
to be working.
Cause: Development of butter on the labyrinth and/or in the cream dispenser. Disassemble and
wash them.
Cause:
Cream type is not suitable to the labyrinth (percentage of fats too high). Try diluting cream with milk or
water. In case of difficulty, call the Assistance Service.
Cause:
The intake tube is obstructed, disassemble and wash it.
Cause:
Air infiltrations in the cream’s pipe. Check that the parts are correctly assembled and the condition of
O-rings, in particular on the intake tube.
Cause:
The pressurisation electrovalve is stopped. Call the Assistance Service.
Cause:
Non-return valve is stopped. Disassemble it and clean it.
Cause:
The pump is damaged. Call the Assistance Service.
Tendency at squirting cream.
Cause:
Air-inlet valve is excessively opened. Reduce it by rotating it on a lower number.
Insufficient or lacking refrigeration.
Panels or ventilation loopholes are obstructed.
Cause:
Overheating due to lack of ventilation. Clean the loopholes, check the correct space around the ma-
chine for a normal ventilation and eventually wait 20 minutes.
Ventilation loopholes are free, space for air circulation around the machine is sufficient, and the free space in
front of the air condenser is correct (min. 20 cm).
Cause:
Refrigerating system had been subjected to repeated ignitions (REFRAIN FROM CARRYING OUT
THIS OPERATION!) and compressor thermic protection automatically switched compressor off. Turn
machine off by means of ON-OFF
Pushbutton, wait 5…10 minutes and turn on again.
Note:
Read Display and check that tub is correctly cooling down: do not only check the buzzing sound be-
cause this comes from FAN and not from compressor.