CHAP 4 - DESCRIPTION OF THE MACHINE 

 

 4.1

 

Technical features 

 

TECHNICAL DATA 

U.M.

F100 T

F100 T/L

F120 T

F120 T/L

 

F200 T

 

F200 T/L

Width                            

mm

806 

818 

806 

818 

1006 

1018 

Length                           

mm

410 

460 

410 

460 

410 

460 

Height                                

mm

695 

695 

945 

945 

945 

945 

Internal width                 

mm

770 

770 

970 

Internal length                 

mm

340 

340 

340 

Internal height                      

mm

370 

620 

620 

Total capacity 

m

3

 0.1 

0.16 

0.20 

Weight 

Kg 

70 85 95 

Maximum power draw  

282 

Power supply voltage     

230 single-phase 

Maximum current draw   

1.5 

Frequency Hz 

50 

 

Power cable cross-section 

mm

2

1.5  

Refrigerating fluid 

 

R134 a 

Refrigerating mass 

Kg 

0.200 

Tab. 4.1 Main technical particulars of the refrigerated display cabinet 

 

4.2

 

Description of the main elements 

 
The refrigerated display cabinet is used to conserve foodstuffs and beverages at a sufficiently low 

temperature. All the components of the display cabinet are shown  in Fig. 2. It is formed by a 
stainless steel framework the windows and the refrigerator unit are fixed in. 

 

Steel framework 

This is the frame of the display cabinet and is formed by: 

Bottom shelf, 

used as base and shelf 

Top, 

used as base for the motor unit, supported by four 

Columns 

Sliding doors. 
Track. 

 

Refrigerator unit 

 

It has a steel or a wooden 

Covering, 

where the controls are and it is formed by: 

Electric compressor, Condenser, Axial fan, Condensate collection basin 
Evaporator and Centrifuge fan, Defrosting timer (Fig. 5), Thermometer, Thermostat and 
Switch 

 

Wiring diagram (see Fig. 4) 

The wiring diagram (Fig. 4) of the various components has been made in accordance with the 

current regulations in the electrical field. 

 

 

4.3 Description of accessories and safety devices 
 

The intermediate 

shelves 

are used as additional surfaces for support. 

 
If you leave accidentally open the doors, the 

automatic closing system 

with sliding doors 

prevents the eventual temperature rising inside the cabinet. 

Содержание F100

Страница 1: ...Mod ORIZ 3G Production code F2000001 F200 02 2015 ...

Страница 2: ...Page 1 of 12 INSTALLATION OPERATION AND SERVICE MANUAL STAINLESS STEEL OR WOODEN REFRIGERATED FOOD DISPLAY CASE mod F100 F120 F200 ...

Страница 3: ...ion of the main elements 5 4 3 Description of accessories and safety devices 5 4 3 1 Regulating thermostat 6 5 PUTTING INTO OPERATION 5 1 Description of operations 6 5 2 Periodical defrosting 6 5 3 Directions to prevent accidents 6 6 MALFUNCTIONING 6 1 Trouble during operation 7 7 CLEANING AND MAINTENANCE 7 1 Directions for cleaning 8 7 2 Special maintenance 8 7 2 1 Replacing the refrigerating uni...

Страница 4: ... for the compressor must not be obstructed CHAP 2 FITTING 2 1 Handling and Unpacking After unpacking check the integrity of the various elements before going ahead with installation in the event of damage or defective components address to professionally qualified personnel 2 2 Connection to the electric network Before carrying out the electrical connection make sure that the specifications of the...

Страница 5: ...x 210 630191 1 450 x 400 x 210 Compressor 630192 1 630192 1 630192 1 Fan 630194 1 630194 1 630194 1 CHAP 3 USER INSTRUCTIONS 3 1 Directions This manual is an integral part of the product It is recommended to read all the information and instructions contained in this manual carefully before starting to use the display cabinet since it contains essential information about the safe use and service o...

Страница 6: ...ponents of the display cabinet are shown in Fig 2 It is formed by a stainless steel framework the windows and the refrigerator unit are fixed in Steel framework This is the frame of the display cabinet and is formed by Bottom shelf used as base and shelf Top used as base for the motor unit supported by four Columns Sliding doors Track Refrigerator unit It has a steel or a wooden Covering where the...

Страница 7: ... minutes four times a day thereby defrosting approximately every six hours of operation This setting can be modified by qualified and authorized personnel possibly by means of the technical service 1 Make sure you have disconnected the electrical power supply 2 Remove the upper cover by unscrewing the two fixing screws 3 Set the defrosting time by moving the indicator A on the wished value of the ...

Страница 8: ... unit Faulty switch thermostat or compressor Refrigerating fluid leakage Too high dissipation Make sure there is power in the electric network Check the correct connection of the power supply cable 7 2 6 Check the different connections and various electrical components and replace them if necessary 7 2 1 and 7 2 3 Check the refrigerating gas circuit The display cabinet is positioned in a too hot p...

Страница 9: ...ION in any case before starting the electrical power supply must be disconnected by deactivating the automatic switch located up line from the appliance 7 2 1 Replacing the refrigerating unit To access the refrigerating unit it is necessary to carry out the following operations 1 Make sure you have disconnected the electrical power supply 2 Remove the top covering by extracting it upwards and taki...

Страница 10: ...ower supply cable To replace the power supply cable it is necessary to carry out the following operations 1 Make sure you have disconnected the electrical power supply 2 Remove the upper cover by drawing it upwards and paying attention to the electric cables 3 Disconnect the two power cables from the switch and the earth lead yellow green from the equipotential screw loosen the external nut and re...

Страница 11: ...3 Structure 14 Defrosting timer 15 Refrigerating unit 16 Neon light 17 Power supply cable 18 Fan 19 Unit switch 20 Neon switch 21 Thermometer 22 Thermostat 23 Upper housing 24 Rear housing 25 Right housing 26 Left housing 27 Front housing 28 Box cover 29 Box with fan and compressor Figur 2 Display cabinet components 1 regulating thermostat 2 thermometer 3 refrigerator unit switch 4 lighting switch...

Страница 12: ... TR regulator thermostat N1 internal lighting lamp GR refrigerating unit Figure 4 Electrical circuit A Indicator defrosting duration B Defrosting duration C Indicator fan delay time D Fan delay time E Defrosting insert F Dial G Knob H Actuator starting operation ...