Page 9 of 11
3. Remove the insulating cover by unscrewing the four screws.
4. Replace the thermometer positioning the sensor in the same position and close it all back up.
7.2.5 Replacing the neon
To replace the neon inside the cabinet it is necessary to carry out the following operations:
1. After making sure you have disconnected the electrical power supply, empty the display
cabinet, removing any trays and shelves as well.
2. Remove the upper cover by unscrewing the two fixing screws.
3. Replace the neon by unscrewing it from the bottom and reconnecting the cables in the same
way.
4. Reposition the covering.
7.2.6 Replacing the power supply cable
To replace the power supply cable it is necessary to carry out the following operations:
1. Make sure you have disconnected the electrical power supply.
2. Remove the upper cover by drawing it upwards and paying attention to the electric cables.
3. Disconnect the two power cables from the switch and the earth lead (yellow-green) from the
equipotential screw, loosen the external nut and remove the power cable. In its place insert the
new one, making it pass through the hole on the instrument panel and connecting it like the one
just removed.
4.
Put the upper cover back into its original position.
FIGURES
MATERIAL
H (mm)
A (mm)
B (mm)
F 100 T
Steel
695
410
806
F 120 T
Steel
945
410
806
F 200 T
Steel
945
410
1006
F 100 T/L
Wood
695
460
818
F 120 T/L
Wood
945
460
818
F 200 T/L
Wood
945
460
1018
Figure 1 - Overall dimensions