E031002C 10/04/09
7
The packing material must not be spread on the environment, but must be collect in the appropriate
collecting place in compliance with the country rules in force.
Remove the transport clamps following with care the instruction inside the
machine side. Pallet and clamps must be stored in case the ironer should be moved in the
future. NOTE: The machine must not be left on the pallet.
Once the machine positioning is completed, the following parts must be mounted on the apposite supports:
Above collecting slide (all the machines)
-
Above collecting slide
-
Below collecting slide
5.
MACHINE IDENTIFICATION
The drying ironer is identified by a label with serial number, model, power and technical characteristics. In
order to order spare parts or request technical assistance the correct machine identification is necessary.
If this label has been modified, damaged or removed the machine cannot be correctly identified, so any
installation or maintenance operation is difficult and the warranty automatically expire.
6.
INSTALLATION PREMISES AND POSITIONING
Installation must be operate by qualified personnel. The machine must be positioned in a flat surface
horizontally and in a very steady way, using the adjustable feet on the ironer side base.
To check the correct position of the ironer using a 1 mt long water level.
For a correct use, working and maintenance, leave at least 500 mm free behind the machine.
For a correct operation of ordinary and extraordinary maintenance, leave on both the
machine side a space equal to the ironer length.
The surface where the machine is position must bear at least 500 kg/m
2
: the machine load can be
considered static. The machine must be positioned in a good aired room (as per the normative in force) and
the room temperature must be b10°C and +35°C. In the room must be granted an air recycle
proportional to the air used by the machine.
The ironer must be vented directly from outside in an environment free from pollution. The ventilation must
be guaranteed by permanent opening on the room walls, which are looking on outside. The net free total
section must comply with local rules on matter.