E031002C 10/04/09
10
1500
Code
Gas kind
Pressure at noozle
Noozle
Air intake position
O
G20
2E e 2H
7,5
440
pos. C: 20 mm
P
G20
2E+
18,8
350
pos. C: 20 mm
Q
G25
2L e 2LL
11
440
pos. D: 15 mm
R
G30 e GPL
3+ e 3B/P
27,7
235
pos. B: 25 mm
1800
Code
Gas kind
Pressure at noozle
Noozle
Air intake position
O
G20
2E e 2H
8,5
440
pos. A: 30 mm
P
G20
2E+
18,9
365
pos. B: 25 mm
Q
G25
2L e 2LL
12,6
440
pos. B: 25 mm
R
G30 e GPL
3+ e 3B/P
28,1
245
no
2100
Code
Gas kind
Pressure at noozle
Noozle
Air intake position
O
G20
2E e 2H
7,5
480
pos. B: 25 mm
P
G20
2E+
18,6
380
pos. B: 25 mm
Q
G25
2L e 2LL
11
480
pos. C: 20 mm
R
G30 e GPL
3+ e 3B/P
27,9
255
pos. B: 25 mm
For the supply system, please use an approved pipe: in case of a rigid pipe, it must be equipped with an
expansion ring
For the gas supplying pipe dimensions, please refer to the attached technical data sheet: the external pipe
system must be adequate to the used kind of gas and in compliance with the rules of the country where the
ironer is going to be installed. Install a pressure reducer correctly dimensioned on the gas supply system and
equipped the line with a valve with manual closure system.
ATTENTION! Gas valve are dimensioned for a pressure up to 55mbar. If the pressure
is above this value, the valve membranes could be broken. For this reason a careful control
of the pressure on the system before the machine installation is compulsory.
11.
PROOF (only for gas heated ironer)
All system and equipment connection must be proofed. We suggest you to use an adequate spay identifying
leaks; otherwise you can spread some foamy not corroding substances. In any case no bubbles must form.
In case there are some leaks, please repair them.
DANGEROUS! Do not use free flames to proof gas leaks!
12.
THE DRYING IRONER
The drying ironer is caracterized by some elements, which must be know from the beginning.