background image

_ Electric Cookers _ rev. 1 _____________________________ CV5P – CV5P5 – CV5E-90 A – CM5E-90 A – 

CV2R _ 

________________________________________________________________________________________ 

page 7 _ 

Type of power cable

 

H07RN-F 

 

 

Safety device

 - The appliance is supplied with a manually resetting thermal breaker to 

protect against excessive, dangerous temperatures which could be accidentally generated 
inside the oven. If tripped, the device cuts out electrical power to the appliance. To access 
this device, remove the panel at the rear of the appliance. 

 
 

6. Adapting cook-top to different types of gas 

 

Mod. CV5P – CV5P5

 

To adapt the hob to a type of gas that differs 

from the one tested in the factory (see data 
plate or supplementary plate), replace the 
nozzles of the five burners Remove the pan 
carrier grilles from the hob and withdraw the 
movable parts of the burners from their seats: 

Remove the pot support grids from the 
cook-top and remove the mobile parts of 
the burners from their position. 

Unscrew the jets (Fig. 2) using the 7 mm. 
Key and replace them with the new ones 
(see table 1). Check the exact 
correspondence of the diameter indicated 
on the table with that printed on the jets. 

After having replaced the jets, set up all the 
parts again and stick the new data on the 
technical data plate. 

 

Fig. 2 

N.B. The burners don’t need any air regulation. 

Minimum level adjustment

 - Burner minimum levels are preset for methane gas (G20) 

operation. If operating on liquid gas (G30/G31) proceed as follows: ignite the burner at 
minimum position, and, using a screwdriver, fully tighten the by-pass adjustment screw at the 
side of the shank of the relevant tap. Check if the flame remains stable and uniform – to help 
you check, rapidly turn the tap knob from maximum to minimum position. When you have 
finished adjusting the by-pass valve, seal it with red paint. Make sure you fit a plate with the 
new installation data. After having set the by-pass screw, seal it with red varnish. 

 
 

 

 

 

 

 

Gas pressure (mbar)

 

 

 

 

 

Type of gas 

Normal 

Max. 

Min. 

Table 1

 

 

 

 

 

G30 

30 35 20 

 

 

 

 

 

G31 

37 45 25 

 

 

 

 

 

G20 

20 25 17 

 

 

Main nozzles diameter 

(1/100 mm)

 

By-pass screw nozzles 

diameter 

(1/100 mm)

 

Consumption calculated with 

gross heat values

 

 

Nominal 

thermal 

capacit

y (kW)

 

Reduce

thermal 

capacit

(kW)

 

G30/G31 

30/37mbar 

G20 

20mbar 

G30/G31 

30/37mbar 

G20 

20mbar 

G30 

30mbar 

(g/h) 

G31 

37mbar 

(g/h) 

G20 

20mbar 

(l/h) 

Содержание C5FV6

Страница 1: ...The catering program Production code CV5P 001 0673 INOX GRIGLIA1 1 Mod C5FV6 01 2005 ...

Страница 2: ...ings 2 Flush fitting in unit furniture 3 Instructions for installer 4 Gas connection 5 Electrical connection 6 Adapting cook top to different types of gas 7 Instructions for use 8 Cleaning and maintenance 9 Wiring layout 10 Technical assistance ...

Страница 3: ...s To ensure the appliance operates correctly the kitchen in which the appliance is installed must be well ventilated in this connection the installer must observe the current national installation norms and subsequent amendments so that an appropriate quantity of air is supplied for the gas combustion setting and for ventilating the room The appliance must discharge the products of combustion into...

Страница 4: ...Appliance category for United Kingdom II2H3 Gas connection Installation class Class 2 subclass 1 Class 1 Factory adjustment Natural gas G20 20 mbar Supply nominal pressure values Liquid gas G30 G31 30 37 mbar Natural gas G20 20 mbar The technical data page is located on the rear panel of the appliance 2 Flush fitting in unit furniture The appliance can be installed as follows Fig 1 Stand alone awa...

Страница 5: ...bsequent amendments The air circulating into the room must arrive directly from openings made in the external walls Fig a Such openings must have a clear 100 cm2 cross section area for the air flow and a 100 cm2 one to discharge combusted gas Should other gas operating appliances be installed such openings must be appropriately enlarged These openings must be located in such a way as not to be obs...

Страница 6: ...gas pipe according to the prescriptions of standards as per current national installation norms and subsequent amendments To connect gas use an approved rigid metal pipe in copper or stainless steel the current national installation norms and subsequent amendments The appliance is equipped with threaded GJ pipes for gas inflow Check if the appliance is designed to operate on the same type of gas a...

Страница 7: ...different appliances by using the appropriate terminal marked with the symbol The equipotential conductor must have a minimum diameter of 10 mm2 The equipotential terminal is at the rear of the appliance When the appliance is operating the supplied voltage must not deviate from the nominal voltage value of 10 Mod CV5P5 CV5E 90 A CM5E 90 A For access to the terminal board remove the rear panel of t...

Страница 8: ...ones see table 1 Check the exact correspondence of the diameter indicated on the table with that printed on the jets After having replaced the jets set up all the parts again and stick the new data on the technical data plate Fig 2 N B The burners don t need any air regulation Minimum level adjustment Burner minimum levels are preset for methane gas G20 operation If operating on liquid gas G30 G31...

Страница 9: ...burners from their position By means of the tool provided unscrew the threaded ferrules A Fig 3 securing the burners to the cook top Remove the chromium plated rings B ensuring not to damage the cables connected to the ignition plugs Remove the elastic rings C securing the thermocouples to the cook top Unscrew the 3 screws securing the central burner triple crown to the cook top Unscrew the 4 scre...

Страница 10: ...lows ignite the burner at minimum position and using a screwdriver fully tighten the by pass adjustment screw at the side of the shank of the relevant tap Check if the flame remains stable and uniform to help you check rapidly turn the tap knob from maximum to minimum position When you have finished adjusting the by pass valve seal it with red paint Make sure you fit a plate with the new installat...

Страница 11: ...ed for about 6 8 sec so as to let the safety thermocouple B heat up Release the knob and turn it to the position desired Fig 7 Should the flame die out the safety thermocouple B will intervene automatically and close the gas cock thus blocking the gas flow to the respective burner To re ignite the burner turn the knob to the off position and repeat the ignition operations after having waited for a...

Страница 12: ...est grill by damaging the protecting enamal in irreparable way OVEN Oven control panel and use Key to symbols Manual operation PROGRAMMING KNOB Fig 9 It functions as interrupter and allows the functioning of the appliance Fig 9 Key to symbols Inside oven light Defreezing FUNCTIONS SELECTOR THERMOSTAT KNOB Fig 10 Selects the type of heating most suitable for different cooking requirements and sets ...

Страница 13: ...20 Turn the programmer knob to the cooking time you require as from now the program is in operation When cooking time has elapsed the appliance is switched off automatically Manual operation You can also use the appliance without selecting cooking time Just turn the programmer knob to the manual position Oven thermostat indicator light This light goes off whenever the oven reaches the selected tem...

Страница 14: ...ghnuts Strudel 1st stage Strudel 2nd stage 160 200 170 180 190 200 100 200 220 200 200 180 200 180 180 200 200 180 20 25 50 45 22 90 220 110 180 100 20 60 40 55 50 20 20 45 How to use the grill The door must stay closed while the grill is being used Put a little oil on the meat or fish to be cooked and always place them on the grill put the grill in the guides nearest or furthest from the grill he...

Страница 15: ... the appliance Turn the selector knob to symbol and the thermostat knob in line with off 8 Cleaning and maintenance ATTENTION Before any operation disconnect the electric supply very that the gas tap is closed and eventually that the appliance has cool down COOK TOP Wash grilles with water and liquid detergents Wash the flame traps and flame trap caps frequently with water and liquid detergents ta...

Страница 16: ...pliance IMPORTANT At least once a year arrange for a qualified technician to inspect the appliances with special reference to gas and electrical connections The manufacturer declines any liability for direct or indirect damage caused by incorrect use poor installation maintenance or anything else specified in our sales conditions 9 Wiring layout WIRING LAYOUT MOD CV5P CV2R Key M Power terminal boa...

Страница 17: ...inal board T1 Safety thermostat T2 Control thermostat A A T ignition device IA Switch A T ignition device MI Door microswitch P End of cooking programmer C Selector for multifunction L1 L2 Oven lamps S Thermostat indicator light B1 Contactor coil B B2 Relay coil B3 Relay coil V1 V2 Radial motoventilators R1 R2Circular heating elements 2500W R3 Grill heating element 2500W R4 Lower heating element 2...

Страница 18: ...____ CV5P CV5P5 CV5E 90 A CM5E 90 A CV2R _ ________________________________________________________________________________________ page 17 _ parts for different gas type adaptation are available along with the appliance at the moment of sale or delivery ...