5. FUNCTIONING / MANIPULATION 

 

a) Installation / assembly

 

- Unpack carefully the appliance from its packaging 
- Place the equipment on a stable surface. 
-  Install  the  machine  in  a  clean,  ventilated  place,  far  away  from  heating  sources  (radiators,  sun 
lights…) 
- Never place the device near a wall or near a partition makes of combustible materials even if it is 
very well isolated. 
- A distance of 10 cm from the partition or the wall is considered enough. 
- Remove the protective film from the appliance. 

 

b) First starting: 

 

First cleaning 
 

Clean the machine before its first use (see 6. Cleaning) 
 

Connection to the main water supply 
 

- Connect the drinking fountain on a stop valve with a male thread 15/21.  
Minimal pressure: 0.6 bar. Maximal pressure: 6 bars 
- The water evacuation circuit must be conceived to avoid any return of liquid waste.  

 

Starting 

 

 

- Open  the stop  valve  and  purge the drinking fountain by  pressing on the control lever  of the filler 
glass. Adjust the flow thanks to the visible adjusting screw on the back part of the fountain.  
- Adjust the flow of the water jet tap to have a suitable trajectory.  
- Switch on when there is no more air in the circuit. 

 

 
Connection of the device 

 

- Check that the tension and the frequency of the electricity network suit to the values indicated on 
the descriptive plate. 
- Check that neither the cord nor the plug are damaged 
- Make sure that every control knob is positioned on 0. 
- Unwind completely the electric power cable and connect it in a normalised plug with the earth. 
- The device is connected. 

 
NB:  in  case  of  connection  of  the  device  in  a  plug  without  earth  protection  or  directly  on  the  electricity 
network, confide its connection to a qualified person

 

 
c) Breakdown / repair: 

 
In case of breakdown  or of damaged part, please call  your  after-sales service and confide any technical 
operation to qualified person. 
 
When you contact the after-sales service of your distributor or your store, give him the complete reference 
of  your  device  (commercial  name,  type  and  serial  number).  This  information  appears  on  the  visible 
descriptive plate behind the device. 

Содержание AQUA 35

Страница 1: ...Mod CR 18S 35 Production code AQUA 35 12 2018 ...

Страница 2: ...1 SG03371 INSTRUCTIONS FOR USE AND INSTALLATION DRINKING FOUNTAIN AQUA 35 Made in France ...

Страница 3: ... without surveillance Never move the appliance when it is working Check that the appliance is definitely off before connecting it up or disconnecting it Do not use the appliance for other functions than determined use Do not leave the electrical cord in contact of hot surfaces The appliance should not be used close to combustible materials To avoid any electric shock never plunge the cord or plug ...

Страница 4: ...ntilated condenser evaporator regulated through a thermostat Hydraulics a water jet tap equipped with an integrated regulator a filler glass a flow limiter Directly connected to the main water supply this drinking fountain provide a constant supply of chilled water 8 to 10 C Glass filler Water jet tap 1 2 1 2 ...

Страница 5: ...ss Adjust the flow thanks to the visible adjusting screw on the back part of the fountain Adjust the flow of the water jet tap to have a suitable trajectory Switch on when there is no more air in the circuit Connection of the device Check that the tension and the frequency of the electricity network suit to the values indicated on the descriptive plate Check that neither the cord nor the plug are ...

Страница 6: ... plug in the water or quite other liquid to avoid any electric shock Never use abrasive product to clean the stainless steel basin Proceed to a regular maintenance of the machine see 11 Maintenance recommendations 7 TECHNICAL SPECIFICATIONS Model AQUA 35 Outside dimensions 400 x 385 x 1245 mm Weight 32 Kg Compressor 0 28 kW Gas R 134 A Water temperature 8 à 10 C Current 2 5 A Voltage 220 240 V Wir...

Страница 7: ... conditions The guarantee grants no right for damages The dispositions which follow are not exclusive of the profit of the legal guarantee planned by articles 1641 and following ones of the Civil code relative to the defects and the latent defects Exclusion clauses of the guarantee Bad installation and bad maintenance in particular if they do not respect current regulations or instructions appeari...

Страница 8: ... Install opaque pipes and the shortest possible Cleaning and disinfection of the new parts see below Cleaning descaling and disinfection of the parts of the drinking fountain At least once a year and in case of abnormal results when control Disassemble the drinking fountain Descaling Make the descaling product circulate inside the evaporator Take off the parts that can be dismantled and immerse th...

Страница 9: ... After not using more than 24 hours The duration of the purge depends on the length of the pipe in which the water stagnates during the night In practice the purge is performed when the water is at the temperature of use Surfaces extérieures grills et cuvette Cleaning Everyday Outdoor surfaces Cleaning with a detergent Rinse Avoid the use of abrasive products Grid and bowl Cleaning with a detergen...

Страница 10: ...ler and basin Cleaning and disinfection Cleaning and disinfection 2 methods can be used 1st method Cleaning with a detergent Rinse Disinfection with chlorinated water at 6 chl time of contact 15 min Rinse 2nd method Cleaning and disinfection with a detergent and dissection solution time of contact according the recommendations of the product manufacturer Rinse Pipes and siphon Cleaning and disinfe...

Страница 11: ...B10013 SH03011_1200 75057 SA03046 SA06043 SB10008 SH03018_1500 SB04066 SA13009 x4 G08102 SH03017 SB04070 SB10019 SB10021 SB10021 SB10030 SA03073 SF01057 SA03012 SA03090 75076 75058EV SB04064 SE02119 SB04065 Date 24 10 2018 Indice A Dessiné par R L Approuvé par AQUA 35 DT196 Date 24 10 2018 ...

Страница 12: ...ERMOSTAT FONTAINE THERMOSTAT FOUNTAIN SA13009 4 VERIN HEXAGONE M8X20 VH 1000 HEXAGON JACK M8X20 SB04064 1 REGULATEUR DE DEBIT FONTAINE FLOW REGULATION SB04065 1 VIS DE REGLAGE DU REGULATEUR REGULATOR ADJUSTMENT SCREW SB04066 1 DESHYDRATEUR DEHYDRATOR SB04070 1 VALVE DE CHARGE 888 1 4 CHARGING VALVE 888 1 4 SB10006 1 ROBINET COL DE CYGNE FONTAINE WATER FILTER TAP DRINKING FOUNTAIN SB10008 1 ROBINET...

Страница 13: ...20 SG03371 Schéma électrique Date 24 10 2018 Indice A Dessiné par R L Approuvé par AQUA 35 DT196 Date 24 10 2018 ...

Отзывы: