![Diamond AQUA 35 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/diamond/aqua-35/aqua-35_instructions-for-use-and-installation_2493495010.webp)
17
SG03371
Preventive cleaning (Machine on)
Method
Frequency
Observations
Descaling
Trimestral
~ Use a descaling agent
~ For the little scaly zones, apply the product with a moistened and
soaked soft clothe.
~ For the very scaly surfaces, apply directly the product to walls to be
treated.
~ Let act the product according to the recommendations of the
manufacturer.
~ Rinse to eliminate any trace of product
Stainless steel surfaces, glass filler and basin
Cleaning and
disinfection
Cleaning and
disinfection
2 methods can be used
* 1st method:
~ Cleaning with a detergent
~ Rinse
~ Disinfection with chlorinated water at 6° chl, time of contact 15 min
~ Rinse
* 2nd method:
~ Cleaning and disinfection with a “detergent and dissection” solution;
time of contact according the recommendations of the product
manufacturer.
~ Rinse
Pipes and siphon
Cleaning and
disinfection without
disassembling
Cleaning and
disinfection
~ Pour chlorinated water at 12° chl. Inside the siphon
~ Contact 15 min
~ Rinse by opening the tap
~ Never mix chlorinated water with a descaling agent (risk of chlorine
gas emanation).