The inside of the cooler should be cleaned with great care.

 

3.1

REGULAR CHECKS 
To be carried out by the User 

- It is recommended that there are no heat sources near to the cooler. 
- The appliance should be well levelled to prevent excessive vibrations. 
- The door Joint is in good working conditions and closes hermetically with the body. 
- The electricity plug is correctly connected to the socket. 
- Check that the water collection tray is in good working conditions (only in some models). 
- Check that the drainage pipe in the chamber is not blocked. 
- Check that the condenser circuit is not blocked with dust. If dirty, call the Technical Service for cleaning.
- Check that the evaporator fan grilles are not blocked by bits of food. 

3.2

NON-USE FOR LONG PERIODS OF TIME 

 

- Disconnect the appliance with the ON / OFF button if it has this option. 
- Disconnect the connection cable. 
- Empty and clean inside. 
- Leave the door with an open gap for air circulation and to prevent mould from forming. 

3.3

GENERAL MACHINE CHECKS 

In the event of having to call for the technician, you can check the machine before ringing. In some cases the 
operating faults that can occur are caused by something simple that the users themselves can solve. 
The following are examples: 

a)  The Cooler does not work

y

 

Check that power reaches the Cooler, looking to see that the main switch is in the ON position 

b) 

 

Temperature too low

y

 

Check that there are no heat sources nearby. 

y

Check that the room temperature is not above +30 ºC, which is the machine’s maximum operating 

temperature. 

y

Check that the goods load is perfectly positioned and does not obstruct the outlets of the inner fan, 

and that the time it has been inside is sufficient to cool the products. 

y

Check that the condenser is clean: You must bear in mind that the cleaner the refrigerator is the 

greater the energy saving, particularly the condenser’s ribbing. The frequency of this cleaning will be 
determined by the characteristics of the premises. If it is dirty, call the technical support service to 
clean it.

y

Check that the doors close properly. 

 
c) 

 

In the event of strange or excessive noise 

y

 

Check the unit's levelling and that the doors close properly. 

y

Check that there are no objects touching any of the cooler's moving components. 

y

Check that the screws (at least the visible ones) are correctly tightened. 

3.4

SPECIAL MAINTENANCE 

(Authorised technical staff) 

y

Condenser cleaning: When cleaning, be careful not to bend the condenser aluminium ribs, as on the 

contrary the air will not come through and will not condense, causing serious damage to the 
appliance and its repair guarantee will be made void.

y

Check that the premise's temperature does not exceed that indicated for your Cooler. 

y

The guarantee will be made void if there is insufficient ventilation. 

y

Check that the doors close properly. 

y

Do not disassemble the mobile components guards without first having 

turned the appliance off

.

y

Use gloves before accessing the area of the condenser unit, given the existence of high temperatures 

of some components, with the resulting risk of burns. 

y

If the power cable is damaged, it should be replaced by authorised technical staff to prevent risks. 

y

It if is replaced, the earth pin must be positioned again.

 

y

If you need to change a cable, you must never use a smaller section. 

y

If it is necessary to disassemble the inner lid of the electrical installation, it is extremely important to 

leave it exactly as it was when reassembling it. 

Содержание 18G300500000

Страница 1: ...Mod GTP 3P Production code 18G300500000 06 2012 ...

Страница 2: ...INSTALLATION USAGE AND MAINTENANCE MANUAL ...

Страница 3: ...TORAGE CYCLE 23 2 9 SET TEMPERATURE HARD POSITIVE CHILLING AND STORAGE CYCLE 24 2 10 TEMPORARY SETTING OF OPERATIONAL SETPOINT DURING STORAGE 25 2 11 TO RE START USING THE SAME SETTINGS AS THE LAST CYCLE RUN 25 2 12 TEST TO CHECK CORRECT PIN PROBE INSERTION 26 2 13 OPERATIONAL STATES 26 2 14 DEFROSTING AND THE EVAPORATOR FAN 26 2 15 VIEWING THE STATUS OF THE COMPRESSOR AND THE EVAPORATOR FAN 26 2 ...

Страница 4: ...lunt object avoiding scratching the steel aluminium is recommended A LEG BODY B SCREW Clockwise to lower the unit Anticlockwise to raise the unit 1 1 CLEANING Before start up Clean the inside of the chamber and accessories with some water and neutral soap to remove the characteristic smell of a new machine When it is clean and dry insert the accessories in the right places according to preferences...

Страница 5: ...stall the Cooler outdoors All coolers should be installed by professional technicians with knowledge on electrical and refrigeration installations If you want to install them in a fixed and definitive place a general drain should be connected to a water fitting in the premises making a drain tap with this drain to prevent cold losses This operation should be carried out by qualified staff The appl...

Страница 6: ... without sound absorbent treatments 2 1 CONSTRUCTION DATA Chamber inside in stainless steel Outer machine panels in stainless steel Coolant R 404 A CFC free Door with automatic closing device model that enables making cooling cycles up to the preservation temperature 2 ºC Two cooling cycles can be made in soft refrigeration and hard refrigeration It has an electronic timer and chamber temperature ...

Страница 7: ...d food from 70 ºC to 3 ºC in 90 minutes During the cooling cycle Do not open the door unit it has ended Do not wrap the product or close the trays Using trays with a height of over 40 mm is not recommended The thickness of the product on the tray is compact from 2 to 2 5 cm Using stainless steel or aluminium containers is recommended During the preserving cycle The product should come in vacuum co...

Страница 8: ...on will be ongoing IF FLASHING and the LED is on then the test to verify correct pin probe insertion will have had a negative outcome param rc and rd and the cycle will have been started in timed mode IF FLASHING and the LED is on the chilling stage will have had a negative outcome and so this will continue IF FLASHING and the LEDs and are on the chilling stage will have had a negative outcome the...

Страница 9: ...assigned by parameter r1 is restored Press within 15 s the cycle will be activated During chilling The display shows the residual chilling time remaining The LED is on the Parameter r1 sets the chilling time duration Parameter r7 sets the operational set point Press several times to Display the message PoS Display the cabinet temperature Exit the procedure or leave for 15 s Once the chilling perio...

Страница 10: ... message End During storage The displays shows the cabinet temperature the LEDs and are on the parameter rA sets the operational set point Press several times to Display the message nEg Exit the procedure or leave for 15 s To interrupt the cycle Press for 2 s 2 8 SET TEMPERATURE SOFT POSITIVE BLAST CHILLING AND STORAGE CYCLE To start the cycle Ensure the device is in stand by mode and no procedure...

Страница 11: ...ll sound for the period of time set by parameter AA press any key to mute the buzzer press once more to cancel the message End During storage The display shows the cabinet temperature If chilling had a positive outcome the LEDs and and will be on If chilling had a negative outcome the LEDs and will be on and the LED will flash the parameter r9 sets the operational set point Press several times to ...

Страница 12: ...he period of time set by parameter AA press any key to mute the buzzer press once more to cancel the message End During storage The display shows the cabinet temperature If chilling had a positive outcome the LEDs and will be on If chilling had a negative outcome the LEDs will be on and the LED will flash the parameter rA sets the operational set point Press several times to Display the message nE...

Страница 13: ...ginning During a storage operation when power is restored the storage operation will be reset State STAND BY The device is switched on but no operating cycle is running If power is interrupted while in stand by mode when power is restored the device will be in the same state 2 14 DEFROSTING AND THE EVAPORATOR FAN The service controlled by relay K2 depends on parameter u0 If u0 0 the service contro...

Страница 14: ...ter C11 is set to 1 the pin probe will function as the cabinet probe and the chilling operation will continue If the error occurs during a set temperature chilling operation If parameter C11 is set to 0 the cycle will be interrupted if parameter C11 is set to 1 the pin probe will function as the cabinet probe and the chilling operation will continue Pr1 Cabinet probe error See PO parameter Check p...

Страница 15: ...handing the control and surroundings of electrical parts or components is not recommended 3 MAINTENANCE With these guidelines we would like to offer both you and the technical assistance service help so that the cooler always works perfectly throughout its useful life We will deal with the cleaning you can carry out as well as a quick machine check before contacting the technical support service W...

Страница 16: ...ner fan and that the time it has been inside is sufficient to cool the products y Check that the condenser is clean You must bear in mind that the cleaner the refrigerator is the greater the energy saving particularly the condenser s ribbing The frequency of this cleaning will be determined by the characteristics of the premises If it is dirty call the technical support service to clean it y Check...

Страница 17: ...aults as long as the machine has been used according to the manual s indications IN THE EVENT OF PART REPAIR OR REPLACEMENT ALWAYS SEND THE APPLIANCE S CODE AND REGISTRATION NUMBER WHICH ARE ON THE NAME PLATE The instructions manual should be read at length as there are some safety guidelines that should be born in mind The company accepts no responsibility if the machine has been handled in any w...

Отзывы: