Diamond Shield Zapper IE Скачать руководство пользователя страница 15

 

 

Diamond Shield Professional  

Instruction Manual 

 

Page 15 

 

Main Menu 

A few seconds after switching on the device, the main menu will be 
displayed.  You  can  always  go  back  from  any  submenu  to  the  main 
menu by pressing (repeatedly) the EXIT button.  

The Main Menu shows the following items: 

 

Chip card:

 This entry is only shown if a chip card is inserted. 

It  allows  you  to  review  and  execute  the  content  of  the  chip 
card. 

 

Standard:

  Via  this  menu  you  can  use  the  preinstalled 

sequences and frequency programs. 

 

Settings:

 Via this menu point you conduct various settings. 

 

 

Important Definitions 

 

Frequency  Program:

  A  frequency  program  includes  all 

features  of  a  single  application,  such  as  the  frequency, 
intensity or duration. 

 

Sequence:

  A  sequence  is  a  serial  arrangement  of  several 

frequency programs. For example, there is a sequence  with 
the  name 

"Diamond  Shield"

,  including  the  frequency 

programs 

DS1, DS2

 ... up to 

26 DS

Содержание Zapper IE

Страница 1: ...Diamond Shield Professional Instruction Manual Page 1 Diamond Shield Zapper IE Instruction Manual Valid for version 2 0 ...

Страница 2: ...Diamond Shield Professional Instruction Manual Page 2 ...

Страница 3: ...enance 8 Feature Identification 9 Front Side 9 Connection Side 10 Back side 11 Bringing into service 12 Insert the battery 12 Connecting the cables 12 Operation 13 Menu Navigation 14 Main Menu 15 Standard menu 16 Display 17 Menu Settings 18 Working with the chip cards 19 Playing frequency programs from a chip card 19 Technical Data 20 Declaration of Conformity 21 For disposal 22 ...

Страница 4: ...Diamond Shield Professional Instruction Manual Page 4 ...

Страница 5: ...2 MHz Possibility of very small voltages 0 1 V to high voltages 16 V Impulse discharge Wobble functionality Modulation of the output frequencies Constant current control Operating frequencies from special chipcards optional accessories The operation can be done via a 9V battery or an appropriate rechargeable battery The device can be used to enhance the well being ...

Страница 6: ...Diamond Shield Professional Instruction Manual Page 6 ...

Страница 7: ...ays insert the grounding cable to the Diamond Shield and then connect it to the power outlet Never use this device to anyone who has a pacemaker Never use this device in the eye area Keep the Diamond Shield always clean and dry wiping it with a damp cloth is permitted Unpacking Before using this device please check of the completeness of the supplied accessories Connection cable for hand or bracel...

Страница 8: ...tect the Diamond Shield from direct sunlight The permissible operating temperature ranges from 15 C to 30 C During storage or transportation the ambient temperature can be between 20 C and 70 C If condensation has been formed during transportation or storage the device must acclimate for about 2 hours and dried by appropriate circulation Thereafter the operation of the device is permitted Nominal ...

Страница 9: ...ond Shield Professional Instruction Manual Page 9 Feature Identification Front Side 1 LED 2 LCD Display 3 Mute Switch 4 START button 5 On Off switch 6 EXIT button 7 OK button 8 Arrow keys 1 2 6 3 4 2 5 8 7 ...

Страница 10: ...Diamond Shield Professional Instruction Manual Page 10 Connection Side 1 Grounding connection 2 Chip card slot 3 Connection for hand or bracelet electrodes 1 2 3 ...

Страница 11: ...Diamond Shield Professional Instruction Manual Page 11 Back side 1 Battery compartment 1 ...

Страница 12: ...ectly according to its polarity If however the battery is inserted incorrectly the device will not be damaged by that We recommend using alkaline batteries or rechargeable batteries Connecting the cables 1 Connect the connection cable for the bracelet electrodes in the right socket above LED 2 Connect the bracelets 3 If you want to work with grounding Connect the grounding cable to the left socket...

Страница 13: ... minutes it will switch off automatically to save battery life Charge condition of the battery The state of charge of the battery is displayed on the LED If the device is switched on the LED flashes When the battery is full the flashing frequency is slow When the battery charge is low the flashing frequency is faster If the battery is empty a message appears and the device can no longer be used Ac...

Страница 14: ...ears when the current list has more entries than can be displayed The scroll bar then indicates where you are in the list If you have already selected the last item in the menu and then you press the down arrow key the first item in the menu will be selected If you press the up arrow key it will go back to the last entry This allows you to change quickly between the last and the first item in the ...

Страница 15: ... allows you to review and execute the content of the chip card Standard Via this menu you can use the preinstalled sequences and frequency programs Settings Via this menu point you conduct various settings Important Definitions Frequency Program A frequency program includes all features of a single application such as the frequency intensity or duration Sequence A sequence is a serial arrangement ...

Страница 16: ...ndividual programs of this sequence will be performed now The device first checks the electrical contact see Contact Control After that all the individual programs of the selected sequence are executed successively Contact Control Before a sequence or a single program will be executed the device checks whether the required electrical contact exists If the contact is not good enough the unit will b...

Страница 17: ...ct Control During the execution of frequencies Display In the headline the sequence name and the name of the current single frequency program are shown in turns Below the remaining execution time is displayed minutes seconds Below the intensity is displayed For frequency programs with current control the actual voltage is displayed on the left side On the right side the selected intensity is displ...

Страница 18: ...guage Select from English or German The input is done with the arrow keys left and right Contrast Adjusts the contrast of the LCD display The input is done with the arrow keys left and right Const amps enables or disables constant current control If you press the left and right arrow then the input is done If NO is selected the intensity of all the frequency programs including those that are store...

Страница 19: ...gardless of the type of chip card their sequences and frequency programs can be played as follows 1 Insert the chip card in the device 2 Press the POWER button 3 Select the menu item chip card from the main menu and press the OK button 4 A submenu will pop up displaying the sequence s of the chip card 5 If you want to play an entire sequence then select this sequence and then press the RUN button ...

Страница 20: ...puts Chip card slot Characteristic of the output signals Frequency range 0 5Hz 2MHz Waveforms square wave signal Minimum accuracy of the frequencies 100 ppm Output Voltage 0 1 16V measured from the 0V line Offset No offset positive offset positive offset 0 3V Modulation up to 254 times the output frequency 2 MHz must not be exceeded Wobble maximum up to twice the fundamental frequency Voltage cont...

Страница 21: ...gen with applicable regulations EMV Richtlinien EMC Directives 2004 108 EG Elektromagnetische Verträglichkeit Electromagnetic compatibility DIN EN 61326 1 VDE 0843 20 1 2006 10 Elektrische Mess Steuer Regel und Laborgeräte EMV Anforderungen Teil 1 Allgemeine Anforderungen IEC 61326 1 2005 Deutsche Fassung EN 61326 1 2006 DIN EN 61326 2 6 VDE 0843 20 2 6 2006 10 Elektrische Mess Steuer Regel und La...

Страница 22: ...iances or return it to the address below unfree postage will not be accepted Please also note that the disposal of batteries is prohibited on the normal household waste for environmental reasons You can return them free of charge to the public collection of communities or wherever batteries are sold You are welcome to return the batteries to the following address unfree postage will not be accepte...

Страница 23: ...ermaVit GmbH Co KG All rights reserved Any kind of reproduction only with approval of DermaVit GmbH Co KG DermaVit GmbH Co KG Unterer Anger 15 Rgb 80331 Munich Germany Tel 49 0 89 18 90 84 6 0 Fax 49 0 89 18 90 84 6 15 E Mail info derma vit com Web http www derma vit com ...

Страница 24: ...Diamond Shield Professional Instruction Manual Page 24 ...

Отзывы: