background image

The electric components of the machine could short circuit when in contact with water or in moist environments. 

In order to ensure the desiccation of the components, the machine should be wiped and kept in a dry environment 

after being used.

Ensure proper ventilation, especially in the area where the batteries are charged. The charger should be equipped 

with an earth lead connecting through the power supply of three cord wire. For the sake of avoiding electrical shock 

hazards, it is highly recommended that a leakage circuit-breaker be pre-installed.

Do not recharge the batteries unless the electric platform truck has been pulled out and the cell cover has been 

removed (with the exception of the maintenance free battery), since gas bubbles might appear during the process 

of recharging. Each time after recharging, remember to refit the cell cover to avoid the spilling of acid liquid.

Do not put any article on the batteries!

Do not put any article on the handlebar!

While cleaning the machine, do not run water into the air inlet of the lift pump!

Safe and economical operation of the machine is only possible if the machine operators are thoroughly familiar 

with the signs and contents on this Operator’s Manual. Failure to do so could be harmful.

This machine is inappropriate for cleaning rough floors and slopes; Operators cannot sit on the machine while 

operating it in these circumstances.

Be aware not to have your hands, legs, or loose clothing in contact with the rotating part of the machine.

Put warning signs on the surrounding area during operation to inform the operator and others that the floor could 

be wet with water or detergents.

Follow safety rules at all times during the process of transportation of this large machine. 

 

 

 

 

 

 

 

 

 

 

CAUTION

Avoid starting the machine or charger where combustible gas or liquid is available.

Avoid laying or placing the machine where combustible gas or liquid is available.

 

 

Содержание DP-SCRUB20

Страница 1: ...OWNER S MANUAL DP SCRUB20 AUTO SCRUBBER USER MAINTENANCE BOOK SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Страница 2: ...he risk of fire this machine is only appropriate for cleaning explosion proof commercial floorings Half installed or half fit machine might cause damage to the operator or others and might also cause casualty to the machine or parts of the machine Before fitting it in completely do not conduct any operation on the machine Before operation one should make sure all components of the machine are well...

Страница 3: ...void the spilling of acid liquid Do not put any article on the batteries Do not put any article on the handlebar While cleaning the machine do not run water into the air inlet of the lift pump Safe and economical operation of the machine is only possible if the machine operators are thoroughly familiar with the signs and contents on this Operator s Manual Failure to do so could be harmful This mac...

Страница 4: ...ng Handle of Squeegee 15 Water Suction Pipe 16 Water Drain Out Pipe 17 Water Valve 18 Metal Frame 19 Wheel 20 Brush 21 Clean Water Filtration 22 Water Level Indicator 23 Solution Tank 24 Dirty Water Tank 25 Dirty Water Tank Cover a Battery Indicator b Suction Motor Button c Brush Motor Button d Brush Install and Release Button e Rate Regulation slow Button f Rate Regulation fast Button g Rate Indi...

Страница 5: ...uid it is useful to wipe the machine with a wet cleaning cloth 9 Maintenance and amendment should be done by professional personnel FUNCTIONS AND NOTES Battery powered and equipped with an automatic walking device The DP SCRUB20 is a professional floor cleaning machine with following characteristics 1 Simple operation All actions including accelerating stopping or retreating can be conducted by op...

Страница 6: ...crew down fixed handle and connect the tube to the machine connection 6 Take out the brush disk or needle bed and then choose a proper brush disk or cleaning pad to prepare for installation in accordance with the floor condition 7 With the lock open the function test is carried on to observe whether the power display and function keys are normal Only after further tests show nothing wrong the next...

Страница 7: ...to the start switch and rotate it to 1 Seen in figure1 to check the battery capacity Op eration should never be carried out until the green light turns on seen in figure2 to indicate the full capacity of the battery 3 Fill the solution tank with clean water add detergent according to the floor status There are 2 ways for water filling see figure 3 Green light x4 Green light x3 Green light x2 Green...

Страница 8: ...n brush on only clean a floor with heavy dirt n both switches on dual cleaning 6 Use pressurized function when cleaning heavy dirt Lifting the handle gives the brush more pressure on the floor Regress to get back to normal See figure 6 7 Control the clean water flow rate by operating the water valve knob according to different floor situations This makes for high efficiency cleaning and no waste b...

Страница 9: ...ient with a suitable included angle see figure8 9 Regulating the pressure between the squeegee and the floor n screw the small casters up to keep them from touching the floor when the squeegee is working then adjust the included angle between the squee gee and floor to have the best working status for the squeegee the included angle is 90 between the rubber blade and floor n screwing the casters d...

Страница 10: ...r side is also worn out it has to be replaced by new rubber blade Note If the brush pad is in the process of being raised the brush motor should not be started up arbitrarily otherwise the brush disk will be removed automatically Figure 12 15 Daily upkeep when operation is finished n clean the machine surface with a wet and dry cloth and open the water tank cover to check and make sure there is no...

Страница 11: ... electrolyte 5 In low temperature when this machine enters the low temperature zone full discharging of the battery should be avoided The charging rate in low temperature will become slow 6 Discharge this machine uses a microcomputer to moni tor the discharging of the battery When the discharge is lower than the specified scale the red light may turn on to alarm the operator At that time the batte...

Страница 12: ...connection l Replace the switch No water came out when cleaning l The solution tank is empty l The hose is blocked l The water adjustment knob is closed l The valve is broken l Add water and detergent in solution tank l Clean the blockage l Turn the knob l Replace the valve The suction power is low when cleaning l Sealed circle and sealed strip are broken l There is debris or a broken area in the ...