Installing the TX 4000 board 

 

TX 4000 PCI SS7 Network Interface Board Installation Manual 

The following illustration shows the H.100 termination DIP switch: 

 

S2

OFF

ON

1

2

34

56

7

8

 

Configuring SS7 Monitor mode 

DIP switch S3 controls the SS7 Monitor mode. The DIP switch is located on the front 
of the board, to the right of the T1/E1 trunk connectors. By default, all S3 switches 

are set to the ON position. This setting disables SS7 Monitor mode. When SS7 
Monitor mode is disabled, the TX board is an active participant in the network. 
To enable SS7 Monitor mode, set the S3 switches to the OFF position. In this mode, 

the board becomes a passive listening device that monitors network traffic. For 
information on connecting the monitoring server (with an installed TX board) to the 
network and installing the SS7 Monitor software, refer to the 

Dialogic® 

NaturalAccess™ SS7 Monitor Developer's Reference Manual 

and to the

 Installing 

Dialogic® NaturalAccess™ SS7 Monitor Software 

instructions

.

 

Note: 

The switches in DIP switch S3 must be set to either all ON or all OFF. 

The following illustration shows the Monitor mode DIP switch: 

 

S3

OFF

ON

12

3

4

 

18 

 

 

 

 

 

 

 

 

Dialogic Corporation 

Содержание TX 4000

Страница 1: ...Dialogic TX 4000 PCI SS7 Network Interface Board Installation Manual July 2009 64 0429 01 www dialogic com...

Страница 2: ...ith intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic More detailed information about such intellectual...

Страница 3: ...04 SRR SS7 4 0 62334 12 August 2004 SRR SS7 4 1 62334 13 April 2005 LBG SS7 4 2 62334 14 July 2008 LBG SS7 5 0 64 0429 01 July 2009 LBG SS7 5 1 Last modified July 7 2009 Refer to www dialogic com for...

Страница 4: ......

Страница 5: ...X 4000 board 21 Using the configuration utility 21 Assigning a CP number 22 Adding a board 23 Changing a CP number 24 Moving a board 25 Removing a board 26 Saving configuration changes 27 Chapter 6 Es...

Страница 6: ...rdware specifications 43 General hardware specifications 43 Physical 43 Host interface 43 H 100 compliant interface 44 Environment 44 Software environment 44 Power requirements 44 Connectivity 44 CEPT...

Страница 7: ...tching and the C programming language Note The product s to which this document pertains is are among those sold by NMS Communications Corporation NMS to Dialogic Corporation Dialogic in December 2008...

Страница 8: ......

Страница 9: ...lligent communication processor CP that plugs into a single PCI bus slot The CP operates with the PCI bus host processor to form a distributed communications application platform The CP features one h...

Страница 10: ...or 3 3 V signaling PCI bus interface that is compliant with the PCI Local Bus Specification Revision 2 2 The PCI interface is a 33 66 MHz 32 bit master target device H 100 bus connectivity The TX 4000...

Страница 11: ...1 RJ 45 interfaces Dialogic NaturalAccess Signaling Software enables you to configure the board as either a T1 or an E1 board Refer to www dialogic com declarations for a list of countries where Dialo...

Страница 12: ...ted by NaturalAccess Signaling Software tasks running on all TX boards If you want to bypass the NaturalAccess layer use the txalarm_ utility to display and optionally log alarm messages txccode Displ...

Страница 13: ...o the Dialogic TX Series SS7 Boards TDM for SS7 Developer s Reference Manual Program Demonstrates how to t1demo Test the T1 E1 and H 100 library functions with TX boards in a system t1stat Receive uns...

Страница 14: ......

Страница 15: ...cable if you are connecting two TX 4000 boards for redundancy support Straight through Ethernet cables if you are connecting to an Ethernet hub or switch in a SIGTRAN network Warning Important safety...

Страница 16: ...al Access Developer s Reference Manual 8 Install the NaturalAccess Signaling Software Installing Dialogic NaturalAccess Signaling Software and Dialogic NaturalAccess Signaling Software Configuration M...

Страница 17: ...on on the board located on each end of the H 100 bus The following illustration shows the H 100 bus configuration Enable bus termination H 100 bus cable Enable bus termination DIP switch S2 on the TX...

Страница 18: ...the TX board is an active participant in the network To enable SS7 Monitor mode set the S3 switches to the OFF position In this mode the board becomes a passive listening device that monitors network...

Страница 19: ...to ON to boot the board to the original software image instead of using the current production software image This allows for recovery from any condition that resulted in the corruption of the product...

Страница 20: ...crews If you are placing the board into an ISA chassis leave the PCI retainer bracket attached to the board The bracket is needed for the board to fit properly into the chassis 5 Remove the blank slot...

Страница 21: ...CP number you will use the txcpcfg utility Depending on the operating environment the txcpcfg utility is located in one of the following directories Operating system Directory Windows Program Files D...

Страница 22: ...undefined board by entering the following command txcpcfg bus slot unique_CP_number where bus is the bus number of the TX 4000 board that you are configuring slot is the slot number of the TX 4000 boa...

Страница 23: ...X 4000 2 4 2 TX 4000 2 6 UNDEFINED TX 4000 5 Record the bus and slot values for the new undefined TX 4000 board 6 Assign a unique CP number to each undefined board by entering the following command tx...

Страница 24: ...oard that you are configuring unique_CP_number is a number you assign Valid CP numbers within the system start at 1 and must be unique They do not have to be consecutive For example enter the followin...

Страница 25: ...unique CP number to the undefined board by entering the following command txcpcfg bus slot unique_CP_number where bus is the bus number of the TX 4000 board that you are configuring slot is the slot...

Страница 26: ...he following command txcpcfg For example if you remove a TX board with a CP number of 2 no configuration information for the removed board is displayed as in the following example Bus Slot CP Number C...

Страница 27: ...odel 2 2 1 TX 4000 2 8 3 TX 4000 2 Using a text editor open the cpcfg configuration file The file contains the original configuration information that existed before you ran the txcpcfg utility and ma...

Страница 28: ......

Страница 29: ...ws the Dialogic MD1 RJ 45 pinouts Pin 8 Port 2 R Receive from network Pin 7 Port 2 T Receive from network Pin 6 Port 2 R1 Transmit to network Pin 5 Port 1 T1 Transmit to network Pin 4 Port 1 R1 Transm...

Страница 30: ...erts the impedance from 120 ohm to 75 ohm No other configuration changes are required For more information contact a Dialogic Services and Support representative Ethernet interfaces The TX 4000 board...

Страница 31: ...to the board If connecting Trunk 3 or Trunk 4 use dual T1 E1 120 ohm trunk adapter cables to connect to the board Each trunk adapter cable divides the 8 pin modular jack on the end bracket into two RJ...

Страница 32: ...perform diagnostic tests remotely The following illustration shows the TX 4000 trunk interface with CSU CSU DSX 1 interface T1 trunk Public service telephone network TX 4000 Note Trunks do not synchro...

Страница 33: ...nd 3 Trunks 2 and 4 Crossover cable The crossover cable connects the transmit signals from one trunk to the receive signals on another trunk by connecting the pins as shown If your board configuration...

Страница 34: ...onfiguration To connect a TX 4000 board to its redundant mate in a TDM configuration use a Category 5 shielded twisted pair STP crossover cable With the crossover cable connect Ethernet 1 on the prima...

Страница 35: ...o the IP network connectors Note Dialogic recommends using a private Ethernet link to connect the redundant boards to avoid loss or delay of vital checkpoint messages However if each board in the redu...

Страница 36: ...e located in two separate chassis to ensure board level and system level redundancy Single node redundant signaling server The following illustration shows how to set up two TX 4000 boards based on a...

Страница 37: ...us LEDs Trunks 1 4 3 2 The TX 4000 board end bracket has one green LED for each trunk The trunk LEDs provide the following indications LED Description Off Trunk has not been configured Slow blinking g...

Страница 38: ...wing table describes the functionality of each LED LED Description LINK ACT Indicates the status of the Ethernet link When the Ethernet link has established link integrity the LED is on and steady It...

Страница 39: ...he following illustration shows the TX 4000 board status LEDs D7 D11 D15 D17 D6 D10 D14 D16 Status LEDs Boot code LEDs D9 D13 D8 D18 D20 D19 D21 D12 Boot code LEDS The boot code LEDs are active when t...

Страница 40: ...task controlled heartbeat The LED flickers to show that the on board operating system is operational D12 Red The board is executing in snapshot mode the board is resetting or txsnap is running D13 Res...

Страница 41: ...odel cpmodel displays each TX board by model type and assigned CP number For example Board 1 is a TX 4000 Board 2 is a TX 4000 4 Ensure that the boards listed by the txcpcfg utility in Step 1 are the...

Страница 42: ......

Страница 43: ...e 5 0 V or 3 3 V signaling compatible slot Input output PCI end bracket Board weight 0 40 lb 0 20 kg Host interface Feature Specification Electrical PCI bus designed to PCI Local Bus Specification Rev...

Страница 44: ...0 C Humidity 5 to 80 non condensing Software environment Feature Description Development environment NaturalAccess Software Operating system Windows UNIX Power requirements State Requirements TX 4000...

Страница 45: ...oss channels under software control Connectors Two Dialogic MD1 RJ 45 interfaces that can support up to four 120 ohm RJ 48C trunk connectors using two dual T1 E1 trunk adapter cables DSX 1 telephony i...

Страница 46: ......

Страница 47: ...21 configuring the hardware 17 DIP switches 17 H 100 bus termination 17 SS7 Monitor mode 18 connectivity 9 44 connectors 29 CP number 21 assigning 22 changing 24 saving changes 27 cpcfg script 27 cpmo...

Страница 48: ...nt 44 H 100 compliant interface 44 host interface 43 power requirements 44 software environment 44 SS7 Monitor mode 18 status LEDs 40 system requirements 15 T T1 9 network connections 31 status LEDs 3...

Отзывы: