Dialogic
®
4000 Media Gateway Series Integration Note
47
•
Under
Line Coding
, select
B8ZS
.
•
Under
Framing
, select
ESF
.
•
Under
Line Build Out
, select
0 dB
.
•
Under
Invert Data
, select
Disable
.
•
Click
Update
and
Close
.
Step 4: Configure the Incoming Call Characteristics as follows:
Select
Config
>
Incoming Call Characteristics
.
•
Set
PRI link number*
to the link number that the T1 QSIG is installed.
•
Set
Trunks*
to
1-23
.
•
Set
DDI Delivery
to
Yes
.
•
Set
CPN Delivery
to
Yes
.
•
Click
Update
and
Close
.