Dialog DA16200 Скачать руководство пользователя страница 18

 

 

      

 

DA16200 AT GUI Tool 

  

User Manual 

Revision 1.0 DRAFT 

03-Jul-2019 

CFR0012 

18 of 20 

© 2020 Dialog Semiconductor 

4.1.4 

Manual Information to the End User  

The OEM integrator has to be aware not to provide information to the end user regarding how to 
install or remove this RF module in the user’s manual of the end product which integrates this 
module.  

4.2 

Canada Statement  

This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept 
any interference, including interference that may cause undesired operation of the device. 
  
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit 
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique 
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 
  

4.2.1 

Caution Exposure: 

This device meets the exemption from the routine evaluation limits in section 2.5 of RSS102 and 
users can obtain Canadian information on RF exposure and compliance. 
Le dispositif répond à l'exemption des limites d'évaluation de routine dans la section 2.5 de RSS102 
et les utilisateurs peuvent obtenir des renseignements canadiens sur l'exposition aux RF et le 
respect. 
  
  
  

4.2.2 

The final end product must be labelled in a visible area with the 
following:       

The Industry Canada certification label of a module shall be clearly visible at all times when installed 
in the host device, otherwise the host device must be labelled to display the Industry Canada 
certification number of the module, preceded by the words “Contains transmitter module”, or the word 
“Contains”, or similar wording expressing the same meaning, as follows:   
Contains transmitter module IC: 25650-DA16200MC, or 25650-DA16200ME. 
  
The module must be installed in WiFi Module. 
  
This End equipment should be installed and operated with a minimum distance of 20cm between the 
radiator and your body. 
  
Cet équipement devrait être installé et actionné avec une distance minimum de 20cm entre le 
radiateur et votre corps. 
  
The end user manual shall include all required regulatory information/warning as show in this 
manual. 

 

Содержание DA16200

Страница 1: ...User Manual DA16200 AT GUI Tool...

Страница 2: ...7 3 2 Board Connection 8 3 3 RF Certification Mode Setup 9 3 3 1 TX Test Mode 9 3 3 2 RX Test Mode 12 3 4 Network Mode Setup 12 3 4 1 Station Mode 13 3 4 2 AP Mode 14 3 5 OTP Mode Setup 16 4 Regulator...

Страница 3: ...guration 9 Figure 10 Debug Console Tx mode 10 Figure 11 Start Stop Tx 11 Figure 12 Debug Console Start Tx 11 Figure 13 Debug Console Stop Tx 11 Figure 14 Rx Configuration 12 Figure 15 Network Mode Con...

Страница 4: ...ous Receiver Transmitter SSID Service Set IDentifier DHCP Dynamic Host Configuration Protocol AP Access Point USB Universal Serial Bus MFC Microsoft Foundation Class References 1 DA16200 Datasheet Dia...

Страница 5: ...The user just needs to connect with a micro USB cable and then two COM ports will be detected automatically If USB port is used install the FT232 Driver for windows In most cases it will be installed...

Страница 6: ...uired to connect to the console of DA16200 Port Com port number on Windows system Baud rate 115 200 bps Data bits 8 bits Parity None Stop bits 1 bit Flow control None Figure 1 Terminal Configuration W...

Страница 7: ...sing prompts when running this tool You need to install Microsoft Visual Studio redistributable package https www microsoft com en us download details aspx id 48145 or copy the dll file into the Windo...

Страница 8: ...tected by the program press the R button to refresh COM Port Figure 4 RS232 Setup Disconnected Select a COM port and click the RS232 OPEN button Wait for a few seconds Connection status will be soon c...

Страница 9: ...Certification Mode Setup To enable certification mode check on the mode option on the Chip Setting tab Figure 7 Certification Mode Configuration Alternatively on the Certification Mode tab Figure 8 C...

Страница 10: ...er test and etc In this mode TX packet is generated continuously over 95 duty cycle CW mode Only single sinewave tone out mode This mode is for freq err check Data Rate Choose modulation type to test...

Страница 11: ...tart TX Stop TX Figure 11 Start Stop Tx Tested setting is 802 11n MCS7 channel 1 100 bytes packet and power grade 0 When you click the Start TX button you can see messages as blow Figure 12 Debug Cons...

Страница 12: ...st Mode RX Setting Channel Support CH1 CH13 Test Time Maximum 3600s Duration is 1 second fixed Figure 14 Rx Configuration RX Packet Rate FCS PHY Overflow packet Total packet Error rate 3 4 Network Mod...

Страница 13: ...ck the Select button on the Mode Select option show in Figure 16 Network mode is changed DA16200 reboots and the station mode setup window will be shown as Figure 18 Figure 17 Debug Console Station Mo...

Страница 14: ...20 Debug Console Connect to AP 3 4 2 AP Mode Choose the AP Mode and click the Select button on the Mode Select option then network mode is changed DA16200 reboots and the AP Mode setup window will be...

Страница 15: ...0 2020 Dialog Semiconductor Figure 23 Debug Console AP Configuration Configure DHCP server Set IP addresses and click the Confirm button When a client is connected its MAC address will be shown as Fig...

Страница 16: ...customer Freq Offset cal The range of frequency offset calibration is 0x0 0x7F MAC Address setup DA16200 provides 4 slots to store MAC addresses and the 1st slot is written by FCI The customer can us...

Страница 17: ...CC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of th...

Страница 18: ...device meets the exemption from the routine evaluation limits in section 2 5 of RSS102 and users can obtain Canadian information on RF exposure and compliance Le dispositif r pond l exemption des limi...

Страница 19: ...DA16200 AT GUI Tool User Manual Revision 1 0 DRAFT 03 Jul 2019 CFR0012 19 of 20 2020 Dialog Semiconductor Revision History Revision Date Description 1 0 03 Jul 2019 Preliminary DRAFT Release...

Страница 20: ...imitation the specification and the design of the related semiconductor products software and applications in accordance with its standard automotive change notification process Applications software...

Отзывы: