UM-GP-006
GreenPAK Pro Development Platform
User Manual
Revision 1.1
15-Sep-2021
CFR0012
28 of 33
© 2021 Dialog Semiconductor
After all settings are done, click button “Emulation” from Emulation Controls window to start emulation
process.
To start all logic and signal generators (expect V
DD
/V
DD2
signal generators) press button “Start All”, see
Figure 28: Emulator Controls Window
Functionality Waveform
Channel 1 (yellow/top)
– Logic generator
Channel 2 (light blue/2nd line)
– Button, 1 - enable Counter; 0 - disable Counter
Channel 3 (magenta/3rd line)
– Counter output
Figure 29: Waveform, Triggered on Button Pressed
Channel 1 (yellow/top)
– Logic generator
Channel 2 (light blue/2nd line)
– Button, 1 - enable Counter; 0 - disable Counter
Channel 3 (magenta/3rd line)
– Counter output