background image

Enter MENU mode, select 

Special Functions

, press the 

ENTER

 button to confirm, use the 

UP/DOWN 

button to select 

Fixture Maintenance

 or 

Factory Setting

.

Fixture Maintenance

To select 

Fixture Maintenance

, press the 

ENTER

 button to show the 

FIXTURE 

MAINTENANCE

 on the display. Use the UP/DOWN button to select 

Interval

 or 

Remain Time

Interval

To select 

Interval,

 press the 

ENTER

 button to confirm, the interval time will be shown on the 

display. Press the 

MENU

 button to exit. 

Remain Time

To select 

Remain Time,

 press the 

ENTER

 button to confirm, the remaining time will be shown 

on the display. Press the 

ENTER

 button to confirm, use the 

UP/DOWN

 button to select 

Exit 

or 

Reset time

, press the 

MENU

 button to exit. 

Factory Setting

To select 

Factory Setting

, press the ENTER button to show the FACTORY SETTING on the 

display. Press the 

ENTER

 button to confirm, use the 

UP/DOWN

 button to select 

No 

or 

Yes 

(the 

fixture will reset to factory settings and exit menu mode).

3.3 Home Position Adjust 

In the main functions, hold  the  

ENTER 

button for at least  3  seconds into offset mode, use  the

DOWN

/

UP

 button up to select 

Pan 

Offset, 

Tilt 

Offset or 

Zoom

 Offset, and press the 

ENTER

 button

to confirm. Use the 

DOWN

/

UP

 button to adjust the home position of the Pan, Tilt or Zoom, Once

the position has been selected,  press the  

ENTER

  button to setup,  to  go back to the functions

without any change press the

 MENU

 button again. Press and hold the 

MENU

 button about one

12D

Содержание IW19-10 ZOOM

Страница 1: ...DIALighting IW19 10 ZOOM User Manual Please read the instruction carefully before use 0D...

Страница 2: ...4 3 DMX 512 Configuration 15 5 Troubleshooting 16 6 Fixture Cleaning 16 1 Safety Instructions WARNING Please keep this User Manual for future consultation If you sell the unit to another user be sure...

Страница 3: ...as it is fire hazard Use safety cables when fixing this unit DO NOT handle the unit by its head only always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where th...

Страница 4: ...fixed to avoid vibration and slipping while operating and make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight...

Страница 5: ...395mm 3 How To Set The Unit 3 1 Control Panel 1 Display Shows the various menus and the selected functions LED 2 POWER ON Power On 3 DMX ON DMX input present 4 Button MENU To select the programming fu...

Страница 6: ...ture 11 Fuse T 6 3A Protects the unit from over voltage or short circuit 3 2 Main Function To select any of the given functions press the MENU button until the required function is showing on the disp...

Страница 7: ...6D...

Страница 8: ...N button to select Pan Inverse Tile Inverse P T Feedback BL O P T Moving White Balance Cooling Mode Dimmer Curve or Dimmer Speed Pan Inverse To select Pan Inverse press the ENTER button to show the PA...

Страница 9: ...tton to confirm and use the UP DOWN button to adjust the value from 125 to 255 press the ENTER button to setup Press the MENU button back to the last menu or let the unit idle one minute to exit menu...

Страница 10: ...lay Warning Display Inverse To select Display Inverse press the ENTER button to show the DISPLAY INVERSE on the display Use the UP DOWN button to select No normal or Yes display inverse Once selected...

Страница 11: ...to Test press the ENTER button to show the AUTO TEST on the display Press the ENTER button the unit will run built in programs to automatically test pan tilt and zoom Press the MENU button back to the...

Страница 12: ...the ENTER button to confirm use the UP DOWN button to select Pan Tilt Zoom or All Pan Tilt To Select Pan Tilt press the ENTER button to show the PAN TILT on the display Use the UP DOWN button to sele...

Страница 13: ...use the UP DOWN button to select Exit or Reset time press the MENU button to exit Factory Setting To select Factory Setting press the ENTER button to show the FACTORY SETTING on the display Press the...

Страница 14: ...tween pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of...

Страница 15: ...DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press the ENTER button...

Страница 16: ...4 3 DMX 512 Configuration 14 channels mode 15D...

Страница 17: ...the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage o...

Страница 18: ...Clean the external optics at least every 30 days 17D...

Страница 19: ...18D...

Страница 20: ...19D...

Отзывы: