background image

Temperature Unit

To Select 

Temperature Unit

, press the 

ENTER

 button to show the 

TEMPERATURE UNIT

 on 

the display. Use the 

UP/DOWN

 button to select 

 or 

, press the 

ENTER

 button to store. Press 

the 

MENU

 button back to the last menu or let the unit idle one minute to exit menu mode.

Display Warning

To select 

Display Warning

, press the 

ENTER

 button to show the 

DISPLAY WARNING

 on the 

display. Use the 

UP/DOWN

 button to select 

No 

(Normal) or 

Yes

 (display will show the error 

warning when the unit went wrong), press the 

ENTER

 button to store. Press the 

MENU

 button 

back to the last menu or let the unit idle one minute to exit menu mode.

Fixture Test

Enter 

MENU

 mode, select 

Fixture Test

, press the 

ENTER

 button to confirm, use the 

UP/DOWN 

button to select

 Auto Test 

or

 Manual Test

Auto Test

To select 

Auto Test

, press the 

ENTER

 button to show the 

AUTO TEST

 on the display. Press 

the 

ENTER

 button, the unit will run built-in programs to automatically test pan, tilt and zoom. 

Press the 

MENU

 button back to the last menu or exit menu mode after auto test.

Manual Test

To select 

Manual Test

, press the 

ENTER

 button to show the 

MANUAL TEST 

on the display. 

Press the 

ENTER

 button, and then use the 

UP/DOWN

 button to select channel, and adjust the 

channel value. Once selected, press the 

ENTER

 button to setup, the fixture will run as the channel 

value indicates. Press the 

MENU

 button back to the last menu or exit menu mode let the unit idle 

one minute. 

(All channels value will become 0 after exiting 

Manual Test 

menu)

Fixture Information

Enter MENU mode, select 

Fixture Information

, press the ENTER button to confirm, use the 

UP/DOWN button to select

 Fixture use time, Lamp On tme 

or

 Firmware Version.

Fixture use time

To select 

Fixture use time

, press the 

ENTER

 button to show the 

FIXTURE USE TIME

 on the 

10D

Содержание IW19-10 ZOOM

Страница 1: ...DIALighting IW19 10 ZOOM User Manual Please read the instruction carefully before use 0D...

Страница 2: ...4 3 DMX 512 Configuration 15 5 Troubleshooting 16 6 Fixture Cleaning 16 1 Safety Instructions WARNING Please keep this User Manual for future consultation If you sell the unit to another user be sure...

Страница 3: ...as it is fire hazard Use safety cables when fixing this unit DO NOT handle the unit by its head only always carry by its base Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where th...

Страница 4: ...fixed to avoid vibration and slipping while operating and make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the fixtures weight...

Страница 5: ...395mm 3 How To Set The Unit 3 1 Control Panel 1 Display Shows the various menus and the selected functions LED 2 POWER ON Power On 3 DMX ON DMX input present 4 Button MENU To select the programming fu...

Страница 6: ...ture 11 Fuse T 6 3A Protects the unit from over voltage or short circuit 3 2 Main Function To select any of the given functions press the MENU button until the required function is showing on the disp...

Страница 7: ...6D...

Страница 8: ...N button to select Pan Inverse Tile Inverse P T Feedback BL O P T Moving White Balance Cooling Mode Dimmer Curve or Dimmer Speed Pan Inverse To select Pan Inverse press the ENTER button to show the PA...

Страница 9: ...tton to confirm and use the UP DOWN button to adjust the value from 125 to 255 press the ENTER button to setup Press the MENU button back to the last menu or let the unit idle one minute to exit menu...

Страница 10: ...lay Warning Display Inverse To select Display Inverse press the ENTER button to show the DISPLAY INVERSE on the display Use the UP DOWN button to select No normal or Yes display inverse Once selected...

Страница 11: ...to Test press the ENTER button to show the AUTO TEST on the display Press the ENTER button the unit will run built in programs to automatically test pan tilt and zoom Press the MENU button back to the...

Страница 12: ...the ENTER button to confirm use the UP DOWN button to select Pan Tilt Zoom or All Pan Tilt To Select Pan Tilt press the ENTER button to show the PAN TILT on the display Use the UP DOWN button to sele...

Страница 13: ...use the UP DOWN button to select Exit or Reset time press the MENU button to exit Factory Setting To select Factory Setting press the ENTER button to show the FACTORY SETTING on the display Press the...

Страница 14: ...tween pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of...

Страница 15: ...DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press the ENTER button...

Страница 16: ...4 3 DMX 512 Configuration 14 channels mode 15D...

Страница 17: ...the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage o...

Страница 18: ...Clean the external optics at least every 30 days 17D...

Страница 19: ...18D...

Страница 20: ...19D...