background image

9

Shutter

064-095

Strobe effect slow to fast

096-127

shutter open

128-159

Pulse-effect in sequences

160-191

shutter open

192-223

Random strobe effect slow to fast

224-255

shutter open

10

Dimmer

0-255

Dimmer 0%...100%

11

Focus

0-255

In(near) to out(far)

12

Prism

0-005

Prism swing out

006-127

Prism swing in

128-189

Forwards rotation from fast to slow

190-193

Prism rotation stop

194-255

Backwards rotation from slow to fast

13

Iris

0-191

Max. diameter to Min.diameter

192-223

Pulse opening fast to slow

224-255

Pulse closing slow to fast

14

Speed

0-255

max to min speed for Pan/Tilt

15

Special

0-019

Color change normal

020-029

Color change to any position

030-039

Color & gobo change to any position

040-079

No function

080-099

Motor reset

100-119

Internal program 1

120-139

Internal program 2

140-159

Internal program 3

160-179

Internal program 4

180-199

Internal program 5

200-219

Internal program 6

220-239

Internal program 7

240-255

Internal program 8

2.

2.

2.

2. S

S

S

Safety

afety

afety

afety IIIInstructions

nstructions

nstructions

nstructions

 

 

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a

safe operation, it is absolutely necessary for the user to follow the safety instructions and warning

notes written in this user manual.

If the device has been exposed to temperature changes due to environmental changes, do not switch

it on immediately. The arising condensation could damage the device. Leave the device switched off

until it has reached room temperature.

This device falls under protection-class I. Therefore it is essential that the device be earthed.

The electric connection must carry out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this manual.

Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case,

replacement of the cable must be done by an authorized dealer.

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the

power cord by the plug. Never pull out the plug by tugging the power cord.

During initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective, it should decrease gradually.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for

smooth air flow, so there should be no shelter for fans and ventilation for heat radiation.

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the

manufacturer or his service agent or a similar qualified person in order to avoid a hazard.