Shutting down
Chapter 8
OPERATION MANUAL
V1.1.0en/13.12.12
Errors and omissions excepted.
Water Cooler
53
8.2
Switch-off
PROCEDURE
Turn >Mains switch<
[37] to “0”.
Disconnect the temperature control unit from the power supply.
8.3
Packing
Use the original packaging wherever possible! Further information can be found on page 22 in sec-
tion
.
8.4
Shipping
Temperature control unit transported in a horizontal position
DAMAGE TO THE COMPRESSOR
Only transport the temperature control unit in an upright position.
H28
Temperature control unit transported incorrectly
PROPERTY DAMAGE
Do not transport by truck on the castors or feet.
Observe all specifications in this section to prevent damage to the temperature control unit.
H31
Transport using the lugs, if fitted, on the top of the temperature control unit. Do not transport the
temperature control unit alone and without aids.
Always use the original packaging for transport.
Always transport the temperature control unit upright on a pallet!
Protect attachments from damage during transport!
During transport, place the temperature control unit on squared timber to protect the cas-
tors/feet.
Secure with tensioning belts/lashing straps rated for the weight concerned.
Additionally secure (depending on model) with plastic film, cardboard and straps.
8.5
Disposal
Uncontrolled or incorrect opening of the refrigerant circuit
RISK OF INJURY AND ENVIRONMENTAL DAMAGE
Work on the refrigerant circuit and disposal of the refrigerant must be carried out by approved
refrigeration/air-conditioning system contractors.
Also observe page 15, section
»Temperature control units with 3 to 30 kg fluorinated greenhou-
.
V23
Improper disposal
ENVIRONMENTAL DAMAGE
Spilled/leaked thermal fluid must be discarded immediately and correctly.
To prevent damage to the environment, have disused temperature control units discarded only
by approved disposal companies (e.g. refrigeration/air-conditioning system contractors).
Also observe page 15, section
»Temperature control units with 3 to 30 kg fluorinated greenhou-
.
V25
NOTE
.
NOTE
.
CAUTION
NOTE
.
Содержание BioAcc-cool
Страница 1: ...Cat No BioAcc cool Water Cooler Version 1 1 ...
Страница 6: ...OPERATION MANUAL Water Cooler Errors and omissions excepted V1 1 0en 13 12 12 6 ...
Страница 10: ...OPERATION MANUAL Water Cooler Errors and omissions excepted V1 1 0en 13 12 12 10 ...
Страница 28: ...Commissioning OPERATION MANUAL Chapter 2 Water Cooler Errors and omissions excepted V1 1 0en 13 12 12 28 ...
Страница 50: ...Service maintenance OPERATION MANUAL Chapter 7 Water Cooler Errors and omissions excepted V1 1 0en 13 12 12 50 ...
Страница 58: ......
Страница 59: ...PAGE 55 www diagenode com ...
Страница 60: ...orders diagenode com orders na diagenode com www diagenode com ...