Product Profile 

DSP-40S Vehicle Detector

 

All this and a 5-Year Warranty too! 

   

 

Features 

Works on any in-ground 
inductive loop from 20 to 
2000 microhenries. 

Designed to be cross talk 
free between other loops 

Automatically compensates 
for loop and lead-In sizes 

Small profile, perfect for 
many installations 

Fail safe operation 

Wide low-voltage operation 

This series of Diablo 
Controls detectors are 
covered by United States 
Patent number  7,132,959 
“Non-Interfering Vehicle 
Detection.” 

  Separate Power/Fail and 

Detect LEDs. 

Overview 

At last a plug-in detector that will operate on any voltage from 10 
to 30 volts AC or DC. The DSP-40S detector is covered by United 
States  patent  number  US  7,132,959  “Non-Interfering  Vehicle 
Detection.”  This  detector  is  virtually  cross-talk  free  in  most 
applications.  It has been specifically designed to handle parking, 
drive-through  and  access  control  applications  where  solid-state 
outputs  are  required  for  both  the  detect  and  fail  outputs.  The 
sensitivity level may be changed. (See below).  The detector loop 
inductance should be

 

between 20 and 2000 microhenries.  

LED Indicators 

The green Power LED will be on steady to indicate the detector is 
operating and powered.  The red Detect LED will turn on when a 
vehicle is over the loop detection area. 

Detect Memory 

Power interruptions of short duration are ignored.  If power fails for 
approximately  1  ½  seconds  or  less  the  detector  “remembers”  a 
vehicle.

 

Sensitivity and Reset Push Button 

The  Reset/Sens.  button  is  used  for  two  functions.    A  short  press 
and release of the button will reset the detector and the LED's will 
both  flash  from  1  to  4  times,  indicating  the  detector's  sensitivity 
level.  The detector is shipped from the factory with the sensitivity 
set at level 3.

 

If a different sensitivity level is required:

 

Push and continue to hold the button until the LED's start flashing. 
Release  the  button  immediately  after  the  desired  number  of 
flashes.  For example, if the sensitivity is to be changed to level 2, 
push  and  hold  the  button  until  the  LED's  flash  twice  then 
immediately  release  the  button.    The  sensitivity  level  can  always 
be verified by a quick tap on the push button.  This will reset the 
detector and flash the two LED's indicating the present level.

 

Level 1 - Very Low 
Level 2 - Low

 

Level 3 - Normal (Factory setting)

 

Level 4 - High

 

Loop or Wire Failures 

In the case of a loop circuit failure, the green LED flashes slowly 
(twice per second) for an open loop circuit failure.  The green LED 
will  flash  fast  (10  times  per  second)  to  indicate  a  shorted  loop 
circuit. 