Electrical Data
Loop Inductance:
20 microhenries to 1500 microhenries (including lead-in inductance). Not all
frequency settings are available at inductances below 30 microhenries.
Operating Voltages:
One wide range power version:
10 volts to 30 volts DC
Solid State Output Rating:
Maximum Output Current: 200 milliamps
Maximum Pull-Up Voltage: 40 volts
Maximum Voltage Drop Across Active Output: 0.3 volts
Current Draw:
10 volts to 30 volts AC or DC
75 milliamps maximum.
Environmental Data
Operating Temperature:
-35°F to 165°F (-37°C to 74°C)
Storage Temperature:
-40°F to 176°F (-40°C to 80°C)
Humidity:
Up to 95% relative humidity non-condensing