Resistance Measurements
Continuity Check
Warning:
TO AVOID ELECTRIC SHOCK, NEVER MEASURE CONTINUITY
ON CIRCUITS OR WIRES THAT HAVE VOLTAGE ON THEM.
1. Set the function switch to the green Ω CAP position.
2. Insert the black lead banana plug into the negative
COM terminal.
3. Insert the red test lead banana plug into the positive Ω
terminal.
4. Press the MODE button to indicate ” “ and “Ω” on
the display
5. Connect the test probe tips to the circuit or wire you
wish to check.
6. If the resistance is less than approximately 35Ω, the
audible signal will sound. If the circuit is open, the
display will indicate “OL”.